Edge Detection Attention Module in Pure Vision Transformer for Low-Dose X-Ray Computed Tomography Image Denoising
Open Access
- 3 March 2025
- journal article
- research article
- Published by MDPI AG in Algorithms
- Vol. 18 (3) , 134
Abstract
X-ray computed tomography (CT) is vital for medical diagnostics, but frequent radiation exposure raises concerns, driving the adoption of low-dose CT (LDCT) to mitigate risks. However, LDCT often introduces noise, compromising diagnostic accuracy. This paper proposes a pure vision transformer (PViT) for LDCT denoising, enhanced with a gradient–Laplacian attention module (GLAM) to improve edge preservation and fine structural detail reconstruction. The model’s robustness was validated across five diverse datasets (piglet, head, abdomen, chest, thoracic), demonstrating consistent performance in preserving anatomical structures. Extensive ablation studies on attention configurations and loss functions further substantiated the contributions of each module. Quantitative evaluation using PSNR and SSIM, alongside radiologist assessment, confirmed significant noise suppression and sharper anatomical boundaries, particularly in regions with fine details such as organ interfaces and bone structures. Additionally, in benchmark comparisons against state-of-the-art LDCT models (RED-CNN, TED-Net, DSC-GAN, DRL-EMP) and traditional methods (BM3D), the model exhibited lower parameter and stable training performance. These findings highlight the model’s robustness, efficiency, and clinical applicability, making it a promising solution for improving LDCT image quality while maintaining computational efficiency.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada (RGPIN-202004441)
This publication has 28 references indexed in Scilit:
- A systematic review of deep learning-based denoising for low-dose computed tomography from a perceptual quality perspectiveBiomedical Engineering Letters, 2024
- Pure Vision Transformer (CT-ViT) with Noise2Neighbors Interpolation for Low-Dose CT Image DenoisingJournal of Imaging Informatics in Medicine, 2024
- Adaptive weighted total variation expansion and Gaussian curvature guided low-dose CT image denoising networkBiomedical Signal Processing and Control, 2024
- A multi-attention Uformer for low-dose CT image denoisingSignal, Image and Video Processing, 2023
- RETRACTED ARTICLE: CT and MRI multi-modal medical image fusion using weight-optimized anisotropic diffusion filteringSoft Computing, 2023
- Multi-Scale Feature Fusion Network for Low-Dose CT DenoisingJournal of Digital Imaging, 2023
- Bilateral Weighted Relative Total Variation for Low-Dose CT ReconstructionJournal of Digital Imaging, 2022
- TED-Net: Convolution-Free T2T Vision Transformer-Based Encoder-Decoder Dilation Network for Low-Dose CT Denoising2021
- Deep Learning for Low-Dose CT Denoising Using Perceptual Loss and Edge Detection LayerJournal of Digital Imaging, 2019
- Sharpness-Aware Low-Dose CT Denoising Using Conditional Generative Adversarial NetworkJournal of Digital Imaging, 2018