Absolute Reliability and Concurrent Validity of the Modified Goniometric Platform for Measuring Trunk Rotation in the Sitting Position
Open Access
- 5 September 2022
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 12 (17) , 8891
Abstract
The modified goniometric platform (MGP) is a novel instrument used to measure trunk rotation while sitting. A lack of reliable and valid evidence has been reported to measure trunk rotation using MGP. Therefore, this study was aimed to investigate the intra- and inter-rater reliabilities and validity of the MGP for measuring trunk rotation while sitting. Methods: Seventeen participants performed right trunk rotation followed by left trunk rotation (three repetitions for each trial) and two random measurements at 40-minute intervals. Inter-rater and intra-rater reliabilities were calculated using intraclass correlation coefficients (ICCs). Validity was assessed using the Pearson correlation coefficient (r). Results: The test and re-test inter-rater reliabilities for right trunk rotation were 0.990 and 0.986, respectively, and those for left trunk rotation were 0.989 and 0.978, respectively. The intra-rater reliabilities for right trunk rotation were 0.949 and 0.954, respectively, and those for left trunk rotation were 0.944 and 0.946, respectively. The right and left trunk rotation validities were 0.986 and 0.981, respectively. Conclusion: MGP is reliable and valid for measuring right and left trunk rotations while sitting.Keywords
Funding Information
- National Sports Institute of Malaysia (008/2021-009/2021)
This publication has 30 references indexed in Scilit:
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Trunk and Hip Biomechanics Influence Anterior Cruciate Loading Mechanisms in Physically Active ParticipantsThe American Journal of Sports Medicine, 2013
- Kinematics of the Thoracic Spine in Trunk RotationSpine, 2012
- Coordination of trunk and pelvis in young and elderly individuals during axial trunk rotationGait & Posture, 2012
- Factors affecting shoulder–pelvic integration during axial trunk rotation in subjects with recurrent low back painEuropean Spine Journal, 2012
- Reliability of Thoracic Spine Rotation Range-of-Motion Measurements in Healthy AdultsJournal of Athletic Training, 2012
- The effects of spinal posture and pelvic fixation on trunk rotation range of motionClinical Biomechanics, 2011
- The Spineangel®: Examining the validity and reliability of a novel clinical device for monitoring trunk motionManual Therapy, 2010
- Test-Retest Reliability and Minimal Detectable Change Scores for the Timed “Up & Go” Test, the Six-Minute Walk Test, and Gait Speed in People With Alzheimer DiseasePhysical Therapy, 2009
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986