Size-dependent scanning parameters (kVp and mAs) for photon-counting spectral CT system in pediatric imaging: simulation study
- 10 May 2016
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (11) , 4105-4126
Abstract
We are developing a photon-counting spectral CT detector with a small pixel size of 0.4 × 0.5 mm 2 , offering a potential advantage for better visualization of small structures in pediatric patients. The purpose of this study is to determine the patient size dependent scanning parameters (kVp and mAs) for pediatric CT in two imaging cases: adipose imaging and iodinated blood imaging. Cylindrical soft-tissue phantoms of diameters between 10–25 cm were used to mimic patients of different ages from 0 to 15 y. For adipose imaging, a 5 mm diameter adipose sphere was assumed as an imaging target, while in the case of iodinated imaging, an iodinated blood sphere of 1 mm in diameter was assumed. By applying the geometry of a commercial CT scanner (GE Lightspeed VCT), simulations were carried out to calculate the detectability index, d ′ 2 , with tube potentials varying from 40 to 140 kVp. The optimal kVp for each phantom in each imaging case was determined such that the dose-normalized detectability index, d ′ 2 / dose, is maximized. With the assumption that the detectability index in pediatric imaging is required the same as in typical adult imaging, the value of mAs at optimal kVp for each phantom was selected to achieve a reference detectability index that was obtained by scanning an adult phantom (30 cm in diameter) in a typical adult CT procedure (120 kVp and 200 mAs) using a modeled energy-integrating system. For adipose imaging, the optimal kVps are 50, 60, 80, and 120 kVp, respectively, for phantoms of 10, 15, 20, and 25 cm in diameter. The corresponding mAs values required to achieve the reference detectability index are only 9%, 23%, 24%, and 54% of the mAs that is used for adult patients at 120 kVp, for 10, 15, 20, and 25 cm diameter phantoms, respectively. In the case of iodinated imaging, a tube potential of 60 kVp was found optimal for all phantoms investigated, and the mAs values required to achieve the reference detectability index are 2%, 9%, 37%, and 109% of the adult mAs. The results also indicate that with the use of respective optimal kVps, the photon-counting spectral system offers up to 30% higher d ′ 2 / dose than the modeled energy-integrating system for adipose imaging, and 70% for iodinated imaging.Keywords
This publication has 29 references indexed in Scilit:
- Effect of Temperature Variation on the Energy Response of a Photon Counting Silicon CT DetectorIEEE Transactions on Nuclear Science, 2013
- Photon-counting spectral computed tomography using silicon strip detectors: a feasibility studyPhysics in Medicine & Biology, 2010
- CT Dosimetry: Comparison of Measurement Techniques and DevicesRadioGraphics, 2008
- Computed Tomography — An Increasing Source of Radiation ExposureNew England Journal of Medicine, 2007
- Pediatric thoracic CT angiographyPediatric Radiology, 2004
- Artifacts in CT: Recognition and AvoidanceRadioGraphics, 2004
- Strategies for Formulating Appropriate MDCT Techniques When Imaging the Chest, Abdomen, and Pelvis in Pediatric PatientsAmerican Journal of Roentgenology, 2004
- Dose Reduction in Pediatric CT: A Rational ApproachRadiology, 2003
- Estimating cancer risks from pediatric CT: going from the qualitative to the quantitativePediatric Radiology, 2002
- Minimizing Radiation Dose for Pediatric Body Applications of Single-Detector Helical CTAmerican Journal of Roentgenology, 2001