  • Size-dependent scanning parameters (kVp and mAs) for photon-counting spectral CT system in pediatric imaging: simulation study

    by Han Chen, Mats Danielsson, Cheng Xu

    We are developing a photon-counting spectral CT detector with a small pixel size of 0.4 × 0.5 mm 2 , offering a potential advantage for better visualization of small structures in pediatric patients. The purpose of this study is to determine the patient size dependent scanning parameters (kVp and mAs) for pediatric CT in two imaging cases: adipose imaging and iodinated blood imaging. Cylindrical soft-tissue phantoms of diameters between 10–25 cm were used to mimic patients of different ages from 0 to 15 y. For adipose imaging, a 5 mm diameter adipose sphere was assumed as an imaging target, while in the case of iodinated imaging, an iodinated blood sphere of 1 mm in diameter was assumed. By applying the geometry of a commercial CT scanner (GE Lightspeed VCT), simulations were carried out to calculate the detectability index, d ′ 2 , with tube potentials varying from 40 to 140 kVp. The optimal kVp for each phantom in each imaging case was determined such that the dose-normalized detectability index, d ′ 2 / dose, is maximized. With the assumption that the detectability index in pediatric imaging is required the same as in typical adult imaging, the value of mAs at optimal kVp for each phantom was selected to achieve a reference detectability index that was obtained by scanning an adult phantom (30 cm in diameter) in a typical adult CT procedure (120 kVp and 200 mAs) using a modeled energy-integrating system. For adipose imaging, the optimal kVps are 50, 60, 80, and 120 kVp, respectively, for phantoms of 10, 15, 20, and 25 cm in diameter. The corresponding mAs values required to achieve the reference detectability index are only 9%, 23%, 24%, and 54% of the mAs that is used for adult patients at 120 kVp, for 10, 15, 20, and 25 cm diameter phantoms, respectively. In the case of iodinated imaging, a tube potential of 60 kVp was found optimal for all phantoms investigated, and the mAs values required to achieve the reference detectability index are 2%, 9%, 37%, and 109% of the adult mAs. The results also indicate that with the use of respective optimal kVps, the photon-counting spectral system offers up to 30% higher d ′ 2 / dose than the modeled energy-integrating system for adipose imaging, and 70% for iodinated imaging.


  • Optimization of beam quality for photon-counting spectral computed tomography in head imaging: simulation study

    by Han Chen, Cheng Xu, Mats Persson, Mats Danielsson

    Head computed tomography (CT) plays an important role in the comprehensive evaluation of acute stroke. Photon-counting spectral detectors, as promising candidates for use in the next generation of x-ray CT systems, allow for assigning more weight to low-energy x-rays that generally contain more contrast information. Most importantly, the spectral information can be utilized to decompose the original set of energy-selective images into several basis function images that are inherently free of beam-hardening artifacts, a potential advantage for further improving the diagnosis accuracy. We are developing a photon-counting spectral detector for CT applications. The purpose of this work is to determine the optimal beam quality for material decomposition in two head imaging cases: nonenhanced imaging and K-edge imaging. A cylindrical brain tissue of 16-cm diameter, coated by a 6-mm-thick bone layer and 2-mm-thick skin layer, was used as a head phantom. The imaging target was a 5-mm-thick blood vessel centered in the head phantom. In K-edge imaging, two contrast agents, iodine and gadolinium, with the same concentration (5  mg/mL) were studied. Three parameters that affect beam quality were evaluated: kVp settings (50 to 130 kVp), filter materials (Z=13 to 83), and filter thicknesses [0 to 2 half-value layer (HVL)]. The image qualities resulting from the varying x-ray beams were compared in terms of two figures of merit (FOMs): squared signal-difference-to-noise ratio normalized by brain dose (SDNR2/BD) and that normalized by skin dose (SDNR2/SD). For nonenhanced imaging, the results show that the use of the 120-kVp spectrum filtered by 2 HVL copper (Z=29) provides the best performance in both FOMs. When iodine is used in K-edge imaging, the optimal filter is 2 HVL iodine (Z=53) and the optimal kVps are 60 kVp in terms of SDNR2/BD and 75 kVp in terms of SDNR2/SD. A tradeoff of 65 kVp was proposed to lower the potential risk of skin injuries if a relatively long exposure time is necessarily performed in the iodinated imaging. In the case of gadolinium imaging, both SD and BD can be minimized at 120 kVp filtered with 2 HVL thulium (Z=69). The results also indicate that with the same concentration and their respective optimal spectrum, the values of SDNR2/BD and SDNR2/SD in gadolinium imaging are, respectively, around 3 and 10 times larger than those in iodine imaging. However, since gadolinium is used in much lower concentrations than iodine in the clinic, iodine may be a preferable candidate for K-edge imaging.


  • On image quality metrics and the usefulness of grids in digital mammography

    by Han Chen, Mats Danielsson, Cheng Xu, Björn Cederström

    Antiscatter grids are used in digital mammography to reduce the scattered radiation from the breast and improve image contrast. They are, however, imperfect and lead to partial absorption of primary radiation, as well as failing to absorb all scattered radiation. Nevertheless, the general consensus has been that antiscatter grids improve image quality for the majority of breast types and sizes. There is, however, inconsistency in the literature, and recent results show that a substantial image quality improvement can be achieved even for thick breasts if the grid is disposed of. The purpose of this study was to investigate if differences in the considered imaging task and experimental setup could explain the different outcomes. We estimated the dose reduction that can be achieved if the grid were to be removed as a function of breast thickness with varying geometries and experimental conditions. Image quality was quantified by the signal-difference-to-noise ratio (SDNR) measured using an aluminum (Al) filter on blocks of poly(methyl methacrylate) (PMMA), and images were acquired with and without grid at a constant exposure. We also used a theoretical model validated with Monte Carlo simulations. Both theoretically and experimentally, the main finding was that when a large 4×8  cm2 Al filter was used, the SDNR values for the gridless images were overestimated up to 25% compared to the values for the small 1×1  cm2 filter, and gridless imaging was superior for any PMMA thickness. For the small Al filter, gridless imaging was only superior for PMMAs thinner than 4 cm. This discrepancy can be explained by a different sensitivity to and sampling of the angular scatter spread function, depending on the size of the contrast object. The experimental differences were eliminated either by using a smaller region of interest close to the edge of the large filter or by applying a technique of scatter correction by subtracting the estimated scatter image. These results explain the different conclusions reported in the literature and show the importance of the selection of measurement methods. Since the interesting structures in mammography are below the 1-cm scale, we advocate the use of smaller contrast objects for assessment of antiscatter grid performance.