Insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system
Open Access
- 1 November 2021
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (3) , 1613-1620
Abstract
Purpose: To demonstrate the capability of insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system.Methods: Insertable inductively coupled volume coils with diameters of 26 and 64 mm (D26 and D64 coils) targeted for monkey and mouse brain specimen sizes were designed and fabricated. These coils were placed inside the imaging volume of a transmit/receive knee coil without wired connections to the main system. Signal‐to‐noise ratio (SNR) evaluations were conducted with and without the insertable coils, and the g‐factor maps of parallel imaging (PI) were also calculated for the D64 coil. Brain specimens were imaged using 3D ‐weighted images with spatial resolution of isotropic 50 and 160 μm using D26 and D64 coils, respectively.Results: Relative average (SD) SNRs compared with knee coil alone were 12.54 (0.30) and 2.37 (0.05) at the center for the D26 and D64 coils, respectively. The mean g‐factors of PI with the D64 coil for the factor of 2 were less than 1.1 in the left‐right and anterior‐posterior directions, and around 1.5 in the superior‐inferior direction or when the PI factor of 3 was used. Acceleration in two directions showed lower g‐factors but suffered from intrinsic low SNR. Representative ‐weighted images of the specimen showed structural details.Conclusion: Inductively coupled small diameter coils insertable to the knee coil demonstrated high SNR and modest PI capability. The concept was successfully used to visualize fine structures of the brain specimen. The insertable coils are easy to handle and enable MR microscopy in a human whole‐body 7T MRI system.Keywords
Funding Information
- Japan Agency for Medical Research and Development (21dm0307003h0004, 20dm0207093)
This publication has 17 references indexed in Scilit:
- Comparison of Histological Techniques to Visualize Iron in Paraffin-embedded Brain Tissue of Patients with Alzheimer’s DiseaseJournal of Histochemistry & Cytochemistry, 2013
- Increased anatomical detail by in vitro MR microscopy with a modified Golgi impregnation methodMagnetic Resonance in Medicine, 2010
- A 7-Tesla High Density Transmit with 28-Channel Receive-Only Array Knee Coil2010
- Comparison of amyloid plaque contrast generated by T2‐weighted, T‐weighted, and susceptibility‐weighted imaging methods in transgenic mouse models of Alzheimer's diseaseMagnetic Resonance in Medicine, 2009
- Correlation of proton transverse relaxation rates (R2) with iron concentrations in postmortem brain tissue from alzheimer's disease patientsMagnetic Resonance in Medicine, 2006
- Image reconstruction in SNR units: A general method for SNR measurement†Magnetic Resonance in Medicine, 2005
- In vivo visualization of Alzheimer's amyloid plaques by magnetic resonance imaging in transgenic mice without a contrast agentMagnetic Resonance in Medicine, 2004
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- AUTO-SMASH: A self-calibrating technique for SMASH imagingMagnetic Resonance Materials in Physics, Biology and Medicine, 1998
- The Consortium to Establish a Registry for Alzheimer's Disease (CERAD)Neurology, 1991