Shinya Handa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shinya Handa has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Atsushi Shima
Human Brain Research Center, Graduate School of Medicine Kyoto University Kyoto Japan
1 shared publication Bill Ding
Quality Electrodynamics Mayfield Village Ohio USA
1 shared publication- Daisuke Yoshii
Department of Neurology, Amagasaki Daimotsu Hospital , Amagasaki
1 shared publication Hirotaka Onoe
Human Brain Research Center Graduate School of Medicine Kyoto University Kyoto Japan
1 shared publication- Hiroyuki Fujita
Sanofi K.K., Tokyo, Japan
1 shared publication - Katsumi Kose
MRIsimulations Inc
1 shared publication
Latest Publications
- Open Access
- 1 November 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (3) , 1613-1620
Insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system
Purpose: To demonstrate the capability of insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system.Methods: Insertable inductively coupled volume coils with diameters of 26 and 64 mm (D26 and D64 coils) targeted for monkey and mouse brain specimen sizes were designed and fabricated. These coils were placed inside the imaging volume of a transmit/receive knee coil without wired connections to the main system. Signal‐to‐noise ratio (SNR) evaluations were conducted with and without the insertable coils, and the g‐factor maps of parallel imaging (PI) were also calculated for the D64 coil. Brain specimens were imaged using 3D ‐weighted images with spatial resolution of isotropic 50 and 160 μm using D26 and D64 coils, respectively.Results: Relative average (SD) SNRs compared with knee coil alone were 12.54 (0.30) and 2.37 (0.05) at the center for the D26 and D64 coils, respectively. The mean g‐factors of PI with the D64 coil for the factor of 2 were less than 1.1 in the left‐right and anterior‐posterior directions, and around 1.5 in the superior‐inferior direction or when the PI factor of 3 was used. Acceleration in two directions showed lower g‐factors but suffered from intrinsic low SNR. Representative ‐weighted images of the specimen showed structural details.Conclusion: Inductively coupled small diameter coils insertable to the knee coil demonstrated high SNR and modest PI capability. The concept was successfully used to visualize fine structures of the brain specimen. The insertable coils are easy to handle and enable MR microscopy in a human whole‐body 7T MRI system.
- 1 November 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (3) , 1613-1620
Open AccessInsertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system
Purpose: To demonstrate the capability of insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system.Methods: Insertable inductively coupled volume coils with diameters of 26 and 64 mm (D26 and D64 coils) targeted for monkey and mouse brain specimen sizes were designed and fabricated. These coils were placed inside the imaging volume of a transmit/receive knee coil without wired connections to the main system. Signal‐to‐noise ratio (SNR) evaluations were conducted with and without the insertable coils, and the g‐factor maps of parallel imaging (PI) were also calculated for the D64 coil. Brain specimens were imaged using 3D ‐weighted images with spatial resolution of isotropic 50 and 160 μm using D26 and D64 coils, respectively.Results: Relative average (SD) SNRs compared with knee coil alone were 12.54 (0.30) and 2.37 (0.05) at the center for the D26 and D64 coils, respectively. The mean g‐factors of PI with the D64 coil for the factor of 2 were less than 1.1 in the left‐right and anterior‐posterior directions, and around 1.5 in the superior‐inferior direction or when the PI factor of 3 was used. Acceleration in two directions showed lower g‐factors but suffered from intrinsic low SNR. Representative ‐weighted images of the specimen showed structural details.Conclusion: Inductively coupled small diameter coils insertable to the knee coil demonstrated high SNR and modest PI capability. The concept was successfully used to visualize fine structures of the brain specimen. The insertable coils are easy to handle and enable MR microscopy in a human whole‐body 7T MRI system.
- 1 June 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (6) , 064708
A high-dynamic-range digital RF-over-fiber link for MRI receive coils using delta–sigma modulation
Coaxial cables commonly used to connect radio-frequency (RF) coil arrays with the control console of an MRI scanner are susceptible to electromagnetic coupling. As the number of RF channels increases, such coupling could result in severe heating and pose a safety concern. Non-conductive transmission solutions based on fiber-optic cables are considered to be one of the alternatives but are limited by the high dynamic range (>80 dB) of typical MRI signals. A new digital fiber-optic transmission system based on delta–sigma modulation (DSM) is developed to address this problem. A DSM-based optical link is prototyped using off-the-shelf components and bench-tested at different signal oversampling rates (OSRs). An end-to-end dynamic range (DR) of 81 dB, which is sufficient for typical MRI signals, is obtained over a bandwidth of 200 kHz, which corresponds to OSR = 50. A fully integrated custom fourth-order continuous-time DSM is designed in 180 nm CMOS technology to enable transmission of full-bandwidth MRI signals (up to 1 MHz) with an adequate DR. Initial electrical test results from this custom chip are also presented.
- 1 June 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (6) , 064708
A high-dynamic-range digital RF-over-fiber link for MRI receive coils using delta–sigma modulation
Coaxial cables commonly used to connect radio-frequency (RF) coil arrays with the control console of an MRI scanner are susceptible to electromagnetic coupling. As the number of RF channels increases, such coupling could result in severe heating and pose a safety concern. Non-conductive transmission solutions based on fiber-optic cables are considered to be one of the alternatives but are limited by the high dynamic range (>80 dB) of typical MRI signals. A new digital fiber-optic transmission system based on delta–sigma modulation (DSM) is developed to address this problem. A DSM-based optical link is prototyped using off-the-shelf components and bench-tested at different signal oversampling rates (OSRs). An end-to-end dynamic range (DR) of 81 dB, which is sufficient for typical MRI signals, is obtained over a bandwidth of 200 kHz, which corresponds to OSR = 50. A fully integrated custom fourth-order continuous-time DSM is designed in 180 nm CMOS technology to enable transmission of full-bandwidth MRI signals (up to 1 MHz) with an adequate DR. Initial electrical test results from this custom chip are also presented.
- Open Access
- 1 August 2007
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 78 (8) , 084705
Single-chip pulse programmer for magnetic resonance imaging using a 32-bit microcontroller
A magnetic resonance imaging (MRI) pulse programmer has been developed using a single-chip microcontroller (ADμC7026). The microcontroller includes all the components required for the MRI pulse programmer: a 32-bit RISC CPU core, 62kbytes of flash memory, 8kbytes of SRAM, two 32-bit timers, four 12-bit DA converters, and 40bits of general purpose I/O. An evaluation board for the microcontroller was connected to a host personal computer (PC), an MRI transceiver, and a gradient driver using interface circuitry. Target (embedded) and host PC programs were developed to enable MRI pulse sequence generation by the microcontroller. The pulse programmer achieved a (nominal) time resolution of approximately 100ns and a minimum time delay between successive events of approximately 9μs. Imaging experiments using the pulse programmer demonstrated the effectiveness of our approach.
- 1 August 2007
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 78 (8) , 084705
Open AccessSingle-chip pulse programmer for magnetic resonance imaging using a 32-bit microcontroller
A magnetic resonance imaging (MRI) pulse programmer has been developed using a single-chip microcontroller (ADμC7026). The microcontroller includes all the components required for the MRI pulse programmer: a 32-bit RISC CPU core, 62kbytes of flash memory, 8kbytes of SRAM, two 32-bit timers, four 12-bit DA converters, and 40bits of general purpose I/O. An evaluation board for the microcontroller was connected to a host personal computer (PC), an MRI transceiver, and a gradient driver using interface circuitry. Target (embedded) and host PC programs were developed to enable MRI pulse sequence generation by the microcontroller. The pulse programmer achieved a (nominal) time resolution of approximately 100ns and a minimum time delay between successive events of approximately 9μs. Imaging experiments using the pulse programmer demonstrated the effectiveness of our approach.