21.3 A Segmented-Interlacing Multi-Phase Hybrid Converter with Inherently Auto-Balanced ILs and Boosted IL Slew Rate During Load Transients

Authors:

Abstract
In datacenters, direct conversion from a $12\mathrm{V}$ input voltage $V_{\text{IN}}$ intermediate bus to point-of-load $(\text{PoL})$ is a common practice for powering computing chips [1], [2]. The increasing computing power necessitates multiple-phase (MP) converters. To reduce power loss, it is crucial to minimize the guard band (between $V_{\text{MIN}}$ and $V_{\text{LOAD}}$) that accommodates the output voltage undershoot during-load transients. This can be achieved by instantaneously increasing the inductor current $(I_{\mathrm{L}})$ slew rate (SR) by energizing all inductors simultaneously in a MP converter [3], [4]. Furthermore, balancing the $I_{\mathrm{L}}\mathrm{s}$ of a MP converter is pivotal for mitigating thermal issues and ensuring system reliability. However, the conventional MP buck, along with MP hybrid converters like MPCCC [5] and IL-MSD [6], exhibit significant $I_{\mathrm{L}}$ imbalance due to duty cycle $D$ mismatches among phases. Consequently, these converters require $I_{\mathrm{L}}$ sensing in each phase and close-loop $D$ adjustments, increasing design complexity and power consumption. While [7] addresses $I_{\mathrm{L}}$ mismatch, it has unequal DC values of $I_{\mathrm{L}}\mathrm{s}$, leading to uneven heat dissipation in the inductors.
Funding Information
  • Macau Science and Technology Development Fund (0041/2022/A1,004/2023/SKL)