Calculation of Toric Intraocular Lens Power with the Barrett Calculator and Data from Three Keratometers
Open Access
- 20 August 2021
- journal article
- research article
- Published by Wiley in Journal of Tropical Medicine
- Vol. 2021, 1-6
Abstract
Aim. To investigate the interdevice agreement for differences in toric power calculated using data on anterior corneal astigmatism obtained with corneal topography/ray-tracing aberrometry (iTrace), partial coherence interferometry (IOLMaster 500), and Scheimpflug imaging (Pentacam). Methods. The analysis included 101 eyes (101 subjects) with regular astigmatism. The main outcome measures were corneal cylinder power, axis of astigmatism, and keratometry values. Toricity and toric IOL power were calculated using the online Barrett toric calculator. Interdevice agreement for measurement and calculation was assessed using a paired sample t-test and a nonparametric test. Results. Significant interdevice differences were noted in the magnitude of astigmatism and flat, steep, and mean keratometry values between iTrace and IOLMaster (all ); in flat, steep, and mean keratometry values (all ) but not in the magnitude of astigmatism ( ) between iTrace and Pentacam; and in the magnitude of astigmatism and steep and mean keratometry values (all ) but not in flat keratometry values ( ) between IOLMaster and Pentacam. The toric IOL power calculated using data from the three devices showed the following trend: iTrace > IOLMaster (0.49 ± 0.36, ) and Pentacam (0.39 ± 0.42, ) and Pentacam was ). There were differences in toricity calculated using data from the three devices ( ). Conclusions. Differences in toric IOL power and toricity calculated using anterior keratometry data from iTrace, IOLMaster 500, and Pentacam should be noted in clinical practice.Keywords
Funding Information
- National Natural Science Foundation of China (81971697, 81501544, B201804)
- Shanxi Eye Hospital (81971697, 81501544, B201804)
- Shanxi Scholarship Council of China (81971697, 81501544, B201804)
This publication has 15 references indexed in Scilit:
- Comparison of a new image-guided system versus partial coherence interferometry, Scheimpflug imaging, and optical low-coherence reflectometry devices: Keratometry and repeatabilityJournal of Cataract & Refractive Surgery, 2016
- Prediction of refractive outcomes with toric intraocular lens implantationJournal of Cataract & Refractive Surgery, 2015
- Comparison of the Pentacam equivalent keratometry reading and IOL Master keratometry measurement in intraocular lens power calculationsClinical & Experimental Ophthalmology, 2013
- Comparability and repeatability of corneal astigmatism measurements using different measurement technologiesJournal of Cataract & Refractive Surgery, 2012
- Univariate and bivariate polar value analysis of corneal astigmatism measurements obtained with 6 instrumentsJournal of Cataract & Refractive Surgery, 2012
- Evaluation of the Comparability and Repeatability of Four Wavefront AberrometersInvestigative Ophthalmology & Visual Science, 2011
- Comparison of Corneal Powers Obtained from 4 Different DevicesAmerican Journal of Ophthalmology, 2009
- Validity of the keratometric index: Evaluation by the Pentacam rotating Scheimpflug cameraJournal of Cataract & Refractive Surgery, 2008
- Surgically induced astigmatism after phacoemulsification in eyes with mild to moderate corneal astigmatismJournal of Cataract & Refractive Surgery, 2006
- Reliability of Orbscan II topography measurements in relation to refractive statusJournal of Cataract & Refractive Surgery, 2005