Haining Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Haining Zhang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Jing Dong
Department of Ophthalmology, First Hospital of Shanxi Medical University, Taiyuan 030001, China
3 shared publications - Xiaogang Wang
Shanxi Eye Hospital Affiliated to Shanxi Medical University
3 shared publications - Suhua Zhang
Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, China
2 shared publications - Zhijie Jia
Department of Ophthalmology, Shanxi Eye Hospital, No. 100 Fudong Street, Taiyuan, 030002, Shanxi, People's Republic of China
2 shared publications Bin Sun
Department of Ophthalmology, Shanxi Eye Hospital, No. 100 Fudong Street, Taiyuan, 030002, Shanxi, People's Republic of China
1 shared publication- Qiang Wu
Affiliated Sixth People's Hospital Shanghai Jiao Tong University, Shanghai, People's Republic of China
1 shared publication
Latest Publications
- Open Access
- 20 August 2021
- Published by Wiley in Journal of Tropical Medicine
- Vol. 2021, 1-6
Calculation of Toric Intraocular Lens Power with the Barrett Calculator and Data from Three Keratometers
Aim. To investigate the interdevice agreement for differences in toric power calculated using data on anterior corneal astigmatism obtained with corneal topography/ray-tracing aberrometry (iTrace), partial coherence interferometry (IOLMaster 500), and Scheimpflug imaging (Pentacam). Methods. The analysis included 101 eyes (101 subjects) with regular astigmatism. The main outcome measures were corneal cylinder power, axis of astigmatism, and keratometry values. Toricity and toric IOL power were calculated using the online Barrett toric calculator. Interdevice agreement for measurement and calculation was assessed using a paired sample t-test and a nonparametric test. Results. Significant interdevice differences were noted in the magnitude of astigmatism and flat, steep, and mean keratometry values between iTrace and IOLMaster (all ); in flat, steep, and mean keratometry values (all ) but not in the magnitude of astigmatism ( ) between iTrace and Pentacam; and in the magnitude of astigmatism and steep and mean keratometry values (all ) but not in flat keratometry values ( ) between IOLMaster and Pentacam. The toric IOL power calculated using data from the three devices showed the following trend: iTrace > IOLMaster (0.49 ± 0.36, ) and Pentacam (0.39 ± 0.42, ) and Pentacam was ). There were differences in toricity calculated using data from the three devices ( ). Conclusions. Differences in toric IOL power and toricity calculated using anterior keratometry data from iTrace, IOLMaster 500, and Pentacam should be noted in clinical practice.
- 20 August 2021
- Published by Wiley in Journal of Tropical Medicine
- Vol. 2021, 1-6
Open AccessCalculation of Toric Intraocular Lens Power with the Barrett Calculator and Data from Three Keratometers
Aim. To investigate the interdevice agreement for differences in toric power calculated using data on anterior corneal astigmatism obtained with corneal topography/ray-tracing aberrometry (iTrace), partial coherence interferometry (IOLMaster 500), and Scheimpflug imaging (Pentacam). Methods. The analysis included 101 eyes (101 subjects) with regular astigmatism. The main outcome measures were corneal cylinder power, axis of astigmatism, and keratometry values. Toricity and toric IOL power were calculated using the online Barrett toric calculator. Interdevice agreement for measurement and calculation was assessed using a paired sample t-test and a nonparametric test. Results. Significant interdevice differences were noted in the magnitude of astigmatism and flat, steep, and mean keratometry values between iTrace and IOLMaster (all ); in flat, steep, and mean keratometry values (all ) but not in the magnitude of astigmatism ( ) between iTrace and Pentacam; and in the magnitude of astigmatism and steep and mean keratometry values (all ) but not in flat keratometry values ( ) between IOLMaster and Pentacam. The toric IOL power calculated using data from the three devices showed the following trend: iTrace > IOLMaster (0.49 ± 0.36, ) and Pentacam (0.39 ± 0.42, ) and Pentacam was ). There were differences in toricity calculated using data from the three devices ( ). Conclusions. Differences in toric IOL power and toricity calculated using anterior keratometry data from iTrace, IOLMaster 500, and Pentacam should be noted in clinical practice.
- Open Access
- 25 July 2018
- Published by Springer Nature in BMC Ophthalmology
- Vol. 18 (1) , 182
Corneal densitometry in high myopia
To investigate corneal densitometry values obtained using Scheimpflug tomography in normal and highly myopic (HM) eyes and to assess the differences in densitometry values between them. Highly myopic and normal corneas were examined using the Pentacam Scheimpflug imaging system. Corneal densitometry was automatically performed over a 12-mm diameter area, which was divided on the basis of annular concentric zones (0–2 mm, 2–6 mm, 6–10 mm, 10–12 mm, total diameter) and depth (anterior layer: inner 120 μm; center layer: from 120 μm to the last 60 μm; posterior layer: last 60 μm; total corneal thickness). A total of 100 normal and 100 HM eyes were enrolled in this study. Upon total corneal thickness densitometry, the HM group was found to have significantly lower values compared with the normal group in 4 annuli, including the 2 mm central zone, 2-6 mm zone, 6–10 mm zone, and 0–12 mm total diameter. Upon anterior layer densitometry, the HM group demonstrated statistically lower values in the 2-6 mm and 6–10 mm zones. Upon densitometry of the central and posterior layers, the HM group was found to have lower values in all annuli. The densitometry map reveals that light backscatter was lower in most portions of the HM cornea than in the normal cornea.
- 25 July 2018
- Published by Springer Nature in BMC Ophthalmology
- Vol. 18 (1) , 182
Open AccessCorneal densitometry in high myopia
To investigate corneal densitometry values obtained using Scheimpflug tomography in normal and highly myopic (HM) eyes and to assess the differences in densitometry values between them. Highly myopic and normal corneas were examined using the Pentacam Scheimpflug imaging system. Corneal densitometry was automatically performed over a 12-mm diameter area, which was divided on the basis of annular concentric zones (0–2 mm, 2–6 mm, 6–10 mm, 10–12 mm, total diameter) and depth (anterior layer: inner 120 μm; center layer: from 120 μm to the last 60 μm; posterior layer: last 60 μm; total corneal thickness). A total of 100 normal and 100 HM eyes were enrolled in this study. Upon total corneal thickness densitometry, the HM group was found to have significantly lower values compared with the normal group in 4 annuli, including the 2 mm central zone, 2-6 mm zone, 6–10 mm zone, and 0–12 mm total diameter. Upon anterior layer densitometry, the HM group demonstrated statistically lower values in the 2-6 mm and 6–10 mm zones. Upon densitometry of the central and posterior layers, the HM group was found to have lower values in all annuli. The densitometry map reveals that light backscatter was lower in most portions of the HM cornea than in the normal cornea.
- Open Access
- 19 June 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17 (1) , 1-6
Anterior lens capsule and epithelium thickness measurements using spectral-domain optical coherence tomography
To investigate the anterior lens capsule and epithelium thickness (defined as anterior lens capsular complex: ALCC) in normal Chinese subjects using spectral-domian optical coherence tomography (SD-OCT) and examine the factors that may influence the ALCC, such as age, gender, pupil diameter (PD) and signal strength index (SSI). A prospective observational case series. One-hundred-thirty-four normal subjects (134 eyes) were included. The ALCCs were determined manually via SD-OCT. Using the pupil center as a reference position, the central ALCC (CALCC), nasal 1-mm ALCC (NALCC), temporal 1-mm ALCC (TALCC) and PD were measured manually. The mean CALCC, NALCC and TALCC were 33 ± 6 μm, 36 ± 7 μm and 34 ± 6 μm, respectively. The NALCC was significantly thicker than the CALCC (P < .001) and TALCC (P < .001). Moreover, CALCC was significantly thinner than TALCC (P = 0.013). Age was positively correlated with the CALCC (r = 0.292, P < .001), NALCC (r = 0.400, P < .001) and TALCC (r = 0.521, P < .001). PD, gender and SSI were not significantly correlated with the three ALCC parameters. The SD-OCT can be used to demonstrate the ALCC thickness, and age is positively correlated with the ALCC in the central, nasal and temporal sides.
- 19 June 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17 (1) , 1-6
Open AccessAnterior lens capsule and epithelium thickness measurements using spectral-domain optical coherence tomography
To investigate the anterior lens capsule and epithelium thickness (defined as anterior lens capsular complex: ALCC) in normal Chinese subjects using spectral-domian optical coherence tomography (SD-OCT) and examine the factors that may influence the ALCC, such as age, gender, pupil diameter (PD) and signal strength index (SSI). A prospective observational case series. One-hundred-thirty-four normal subjects (134 eyes) were included. The ALCCs were determined manually via SD-OCT. Using the pupil center as a reference position, the central ALCC (CALCC), nasal 1-mm ALCC (NALCC), temporal 1-mm ALCC (TALCC) and PD were measured manually. The mean CALCC, NALCC and TALCC were 33 ± 6 μm, 36 ± 7 μm and 34 ± 6 μm, respectively. The NALCC was significantly thicker than the CALCC (P < .001) and TALCC (P < .001). Moreover, CALCC was significantly thinner than TALCC (P = 0.013). Age was positively correlated with the CALCC (r = 0.292, P < .001), NALCC (r = 0.400, P < .001) and TALCC (r = 0.521, P < .001). PD, gender and SSI were not significantly correlated with the three ALCC parameters. The SD-OCT can be used to demonstrate the ALCC thickness, and age is positively correlated with the ALCC in the central, nasal and temporal sides.