Refixation of a Large Osteochondral Fragment with Magnesium Compression Screws—A Case Report
Open Access
Abstract
Introduction: Osteochondrosis dissecans (OCD) is a disease affecting the subchondral bone and the overlying articular cartilage. The etiology is most likely a combination of biological and mechanical factors. The incidence is highest in children >12 years old and it predominantly affects the knee. In high-grade OCD lesions, free osteochondral fragments usually are refixed via titanium screws or biodegradable screws or pins. In this case, headless compression screws made from magnesium were used for refixation. Case report: A thirteen-year-old female patient with a two-year history of knee pain was diagnosed with an OCD lesion of the medial femoral condyle. After initial conservative treatment, displacement of the osteochondral fragment occurred. Refixation was performed using two headless magnesium compression screws. At the 6 months follow up, the patient was pain free, and the fragment showed progressive healing while the implants were biodegrading. Discussion: Existing implants for refixation of OCD lesions either require subsequent removal or show less stability and possible inflammatory reactions. The new generation of magnesium screws used in this case did not lead to a gas release, as described for previous magnesium implants, while maintaining stability during continuous biodegradation. Conclusions: The data available to date on magnesium implants for the treatment of OCD are promising. However, the evidence on the magnesium implants in refixation surgery of OCD lesions is still limited. Further research needs to be conducted to provide data on outcomes and possible complications.Keywords
Funding Information
- University of Muenster
This publication has 45 references indexed in Scilit:
- Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot studyBioMedical Engineering OnLine, 2013
- Surgical management of osteochondritis dissecans of the kneeCurrent Reviews in Musculoskeletal Medicine, 2013
- Bioabsorbable Fixation of Unstable Osteochondritis Dissecans LesionsThe American Journal of Sports Medicine, 2010
- Fixation of osteochondral fragments in the human knee using Meniscus Arrows®Knee Surgery, Sports Traumatology, Arthroscopy, 2010
- Surgical Treatment Options for Osteochondritis Dissecans of the KneeSports Health: A Multidisciplinary Approach, 2009
- Osteochondritis dissecans and Osgood Schlatter disease in a family with Stickler syndromePediatric Rheumatology, 2009
- Degradable biomaterials based on magnesium corrosionCurrent Opinion in Solid State and Materials Science, 2008
- Comparison of Bioabsorbable Pins and Nails in the Fixation of Adult Osteochondritis Dissecans Fragments of the KneeThe American Journal of Sports Medicine, 2007
- Early lesions of osteochondrosis in the distal tibia of foalsJournal of Orthopaedic Research, 2007
- Results after microfracture of full-thickness chondral defects in different compartments in the kneeOsteoarthritis and Cartilage, 2006