Thorben Briese
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Thorben Briese has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Adrian Deichsel
Klinik für Unfall‑, Hand- und Wiederherstellungschirurgie, Universitätsklinikum Münster, Münster, Deutschland
6 shared publications- Christoph Kittl
Department of Trauma, Hand and Reconstructive Surgery University of Muenster Muenster Germany
6 shared publications Christian Peez
Department of Trauma, Hand and Reconstructive Surgery University Hospital Muenster Muenster Germany
5 shared publicationsElmar Herbst
Department of Trauma, Hand and Reconstructive Surgery University Hospital Muenster Muenster Germany
5 shared publicationsMichael J. Raschke
Department of Trauma, Hand and Reconstructive Surgery University Hospital Muenster Muenster Germany
5 shared publications- Adrian Deichsel
Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany
3 shared publications
Latest Publications
- 4 July 2025
- Published by Springer Nature in Arthroskopie
- Vol. 38 (4) , 319-325
Stellenwert und Evidenz der Stressradiographie in der Diagnostik ligamentärer Kniegelenksinstabilitäten
- 4 July 2025
- Published by Springer Nature in Arthroskopie
- Vol. 38 (4) , 319-325
Stellenwert und Evidenz der Stressradiographie in der Diagnostik ligamentärer Kniegelenksinstabilitäten
- Open Access
- 19 May 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 34 (3) , 844-854
Several flat tendon graft types are viable options for flat superficial medial collateral ligament reconstructions—A biomechanical analysis
Purpose: Flat superficial medial collateral ligament (sMCL) reconstruction helps restore knee kinematics in medial instability, but recommendations on grafts that best mimic the sMCL's biomechanical properties are missing. This study aimed to compare the biomechanical properties of flat grafts to the native sMCL, hypothesizing that (1) flat grafts exhibit unique biomechanical properties and (2) graft configuration affects their biomechanical properties. Study Design: Controlled laboratory study. Methods: The sMCL, semitendinosus, gracilis, quadriceps tendons and iliotibial band (ITB) were harvested from 20 fresh‐frozen human cadaveric knees. Flat grafts were prepared, providing single‐ and double‐strand grafts. The following groups ( n = 10 each) were defined: (1) native sMCL, (2) single‐strand semitendinosus tendon (SemiT single), (3) double‐strand semitendinosus tendon (SemiT double), (4) single‐strand gracilis tendon (Gracilis single), (5) double‐strand gracilis tendon (Gracilis double), (6) single‐strand ITB (ITB single), (7) double‐strand ITB (ITB double) and (8) superficial layer of the quadriceps tendon (Quad). Using a universal uniaxial testing machine, the grafts were preconditioned (10 cycles, 10–50 N) and subsequently loaded to failure (LTF) (20 mm/min). Biomechanical properties of the grafts were compared using a one‐way analysis of variance with post hoc correction ( p < 0.05). Results: Double‐strand configuration of the hamstring tendons and the ITB resulted in a significant increase in stiffness, LTF and yield load ( p < 0.05) and a significant decrease in tensile stress and ultimate strain ( p < 0.05) compared to single‐strand grafts. Single‐strand SemiT and Quad, as well as double‐strand Gracilis and ITB grafts, demonstrated comparable biomechanical properties to the native sMCL (n.s.). In contrast, double‐strand SemiT tendon grafts exhibited significantly greater stiffness, LTF and yield load compared to the native sMCL ( p < 0.01). Conversely, single‐strand graft configuration of Gracilis and ITB resulted in significantly lower stiffness, LTF and yield load ( p < 0.01) and higher tensile stress and ultimate strain ( p < 0.001) compared to the native sMCL. Conclusion: The graft type and configuration of the grafts significantly affects the biomechanical properties of flat sMCL grafts. Single‐strand SemiT and Quad, and double‐strand Gracilis and ITB grafts, mimic the biomechanical properties of the native sMCL, representing viable options for flat sMCL reconstructions. In contrast, double‐strand SemiT grafts exceeded these properties, while single‐strand Gracilis and ITB grafts demonstrate decreased biomechanical properties, possibly resulting in increased risk of medial overconstraint or residual laxity. Level of Evidence: There is no level of evidence as this study was an experimental laboratory study.
- 19 May 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 34 (3) , 844-854
Open AccessSeveral flat tendon graft types are viable options for flat superficial medial collateral ligament reconstructions—A biomechanical analysis
Purpose: Flat superficial medial collateral ligament (sMCL) reconstruction helps restore knee kinematics in medial instability, but recommendations on grafts that best mimic the sMCL's biomechanical properties are missing. This study aimed to compare the biomechanical properties of flat grafts to the native sMCL, hypothesizing that (1) flat grafts exhibit unique biomechanical properties and (2) graft configuration affects their biomechanical properties. Study Design: Controlled laboratory study. Methods: The sMCL, semitendinosus, gracilis, quadriceps tendons and iliotibial band (ITB) were harvested from 20 fresh‐frozen human cadaveric knees. Flat grafts were prepared, providing single‐ and double‐strand grafts. The following groups ( n = 10 each) were defined: (1) native sMCL, (2) single‐strand semitendinosus tendon (SemiT single), (3) double‐strand semitendinosus tendon (SemiT double), (4) single‐strand gracilis tendon (Gracilis single), (5) double‐strand gracilis tendon (Gracilis double), (6) single‐strand ITB (ITB single), (7) double‐strand ITB (ITB double) and (8) superficial layer of the quadriceps tendon (Quad). Using a universal uniaxial testing machine, the grafts were preconditioned (10 cycles, 10–50 N) and subsequently loaded to failure (LTF) (20 mm/min). Biomechanical properties of the grafts were compared using a one‐way analysis of variance with post hoc correction ( p < 0.05). Results: Double‐strand configuration of the hamstring tendons and the ITB resulted in a significant increase in stiffness, LTF and yield load ( p < 0.05) and a significant decrease in tensile stress and ultimate strain ( p < 0.05) compared to single‐strand grafts. Single‐strand SemiT and Quad, as well as double‐strand Gracilis and ITB grafts, demonstrated comparable biomechanical properties to the native sMCL (n.s.). In contrast, double‐strand SemiT tendon grafts exhibited significantly greater stiffness, LTF and yield load compared to the native sMCL ( p < 0.01). Conversely, single‐strand graft configuration of Gracilis and ITB resulted in significantly lower stiffness, LTF and yield load ( p < 0.01) and higher tensile stress and ultimate strain ( p < 0.001) compared to the native sMCL. Conclusion: The graft type and configuration of the grafts significantly affects the biomechanical properties of flat sMCL grafts. Single‐strand SemiT and Quad, and double‐strand Gracilis and ITB grafts, mimic the biomechanical properties of the native sMCL, representing viable options for flat sMCL reconstructions. In contrast, double‐strand SemiT grafts exceeded these properties, while single‐strand Gracilis and ITB grafts demonstrate decreased biomechanical properties, possibly resulting in increased risk of medial overconstraint or residual laxity. Level of Evidence: There is no level of evidence as this study was an experimental laboratory study.
- Open Access
- 1 April 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (2) , e70310
A novel meniscal root refixation pull‐in technique with an all‐suture anchor shows biomechanical properties comparable to standard suture anchor and transtibial pull‐out techniques
Purpose: Repair techniques for posterior meniscal root (PMMR) tears include repair with transtibial pull‐out and anchors. An alternative approach uses all‐suture anchors pulled in, avoiding a posterior medial portal. While clinical feasibility has been assessed, biomechanical properties of this technique remain unknown. We hypothesised that the biomechanical properties using the pull‐in technique would be comparable to those achieved with conventional repair techniques.Methods: Fifty fresh‐frozen porcine tibiae were fixed in a steel pot. Whereas in group (1) the native meniscal root was kept intact (native meniscal root (NM)), the PMMR was sectioned and refixed in groups (2)–(5): (2) Double‐loaded suture anchor (screw anchor) (SA), (3) transtibial pull‐out repair with two sutures (TTPO), (4) double‐loaded pull‐in repair with all‐suture anchor that was pulled into the subcortical bone which was predrilled from retrograde direction (PULL) and (5) double‐loaded push‐in repair with all‐suture anchor traditionally pushed into the predrilled subcortical bone in antegrade direction (PUSH). Testing was performed using a universal testing machine with 1000 cycles (5–20 N/0.5 Hz) with subsequent load‐to‐failure (LTF) meaning failure of the NM or refixation. Outcomes measured included LTF (N), cyclic displacement (mm), and stiffness (N/mm). The failure mode was documented macroscopically.Study design: Controlled laboratory study.Results: No repair technique restored the stability of the NM, reaching 1064.6 ± 226.0 N in LTF (p ≤ 0.0001). Reconstructions had significantly lower LTF: SA (251.4 ± 52.8 N), TTPO (233.4 ± 50.0 N), PULL (206.2 ± 86.5 N) and PUSH (214.3 ± 55.2 N). The NM showed the highest stiffness with 156.1 ± 76.3 N/mm (p ≤ .0001) compared to (SA) 36.2 ± 10.1 N/mm, (TTPO) 33.6 ± 6.2 N/mm, (PULL) 36.8 ± 12.7 N/mm, (PUSH) 27.7 ± 6.6 N/mm. Increased displacement after 1000 cycles was shown, with (2.3 ± 0.7 mm) in PULL, only with significant differences noted between NM (1.5 ± 0.8 mm) and PUSH (3.1 ± 0.7 mm) (p ≤ .001), NM and SA (2.5 ± 0.8 mm) (p ≤ .05), and TTPO (2.1 ± 0.7 mm) and PUSH (p ≤ .05). No failures occurred during cyclic loading. Failure after LTF was always a suture cut‐out at the meniscus.Conclusion: Current repair techniques for posterior medial root tears do not fully restore the biomechanical properties of an intact root. The new pull‐in technique with an all‐suture anchor which is pulled in instead of pushed in shows biomechanical properties comparable to conventional methods, especially regarding LTF.Level of Evidence: There is no level of evidence as this study was an experimental laboratory study.
- 1 April 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (2) , e70310
Open AccessA novel meniscal root refixation pull‐in technique with an all‐suture anchor shows biomechanical properties comparable to standard suture anchor and transtibial pull‐out techniques
Purpose: Repair techniques for posterior meniscal root (PMMR) tears include repair with transtibial pull‐out and anchors. An alternative approach uses all‐suture anchors pulled in, avoiding a posterior medial portal. While clinical feasibility has been assessed, biomechanical properties of this technique remain unknown. We hypothesised that the biomechanical properties using the pull‐in technique would be comparable to those achieved with conventional repair techniques.Methods: Fifty fresh‐frozen porcine tibiae were fixed in a steel pot. Whereas in group (1) the native meniscal root was kept intact (native meniscal root (NM)), the PMMR was sectioned and refixed in groups (2)–(5): (2) Double‐loaded suture anchor (screw anchor) (SA), (3) transtibial pull‐out repair with two sutures (TTPO), (4) double‐loaded pull‐in repair with all‐suture anchor that was pulled into the subcortical bone which was predrilled from retrograde direction (PULL) and (5) double‐loaded push‐in repair with all‐suture anchor traditionally pushed into the predrilled subcortical bone in antegrade direction (PUSH). Testing was performed using a universal testing machine with 1000 cycles (5–20 N/0.5 Hz) with subsequent load‐to‐failure (LTF) meaning failure of the NM or refixation. Outcomes measured included LTF (N), cyclic displacement (mm), and stiffness (N/mm). The failure mode was documented macroscopically.Study design: Controlled laboratory study.Results: No repair technique restored the stability of the NM, reaching 1064.6 ± 226.0 N in LTF (p ≤ 0.0001). Reconstructions had significantly lower LTF: SA (251.4 ± 52.8 N), TTPO (233.4 ± 50.0 N), PULL (206.2 ± 86.5 N) and PUSH (214.3 ± 55.2 N). The NM showed the highest stiffness with 156.1 ± 76.3 N/mm (p ≤ .0001) compared to (SA) 36.2 ± 10.1 N/mm, (TTPO) 33.6 ± 6.2 N/mm, (PULL) 36.8 ± 12.7 N/mm, (PUSH) 27.7 ± 6.6 N/mm. Increased displacement after 1000 cycles was shown, with (2.3 ± 0.7 mm) in PULL, only with significant differences noted between NM (1.5 ± 0.8 mm) and PUSH (3.1 ± 0.7 mm) (p ≤ .001), NM and SA (2.5 ± 0.8 mm) (p ≤ .05), and TTPO (2.1 ± 0.7 mm) and PUSH (p ≤ .05). No failures occurred during cyclic loading. Failure after LTF was always a suture cut‐out at the meniscus.Conclusion: Current repair techniques for posterior medial root tears do not fully restore the biomechanical properties of an intact root. The new pull‐in technique with an all‐suture anchor which is pulled in instead of pushed in shows biomechanical properties comparable to conventional methods, especially regarding LTF.Level of Evidence: There is no level of evidence as this study was an experimental laboratory study.
- Open Access
- 31 March 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (2) , e70225
Impact of screw design on refixation of solid avulsion fractures of the posterior cruciate ligament—A biomechanical feasibility study
Purpose: Avulsion fractures of the posterior cruciate ligament (PCL) are commonly treated with refixation. Headless compression screws (HCS) offer benefits, compared to conventional techniques, such as reduced material irritation and option of bioabsorbable materials, possibly avoiding implant removal. Proofing its clinical applicability, the authors hypothesized that (1) biomechanical properties of HCS would be comparable to conventional techniques and (2) magnesium‐based HCS would provide comparable properties to titanium HCS.Study Design: Controlled laboratory study.Methods: Forty fresh frozen porcine knees were dissected keeping the menisci and ligaments intact. A solid avulsion fracture of the tibial PCL (20 mm [length] × 20 mm [width] × 10 mm [depth]) was created with a chisel. Specimens were randomized into four groups: (1) the native PCL, the tibial PCL avulsion refixed with parallel arranged, (2) two 3.5 mm cortical screws with washer (Ti‐CS), (3) two titanium headless compression screws (Ti‐HCS) or (4) two magnesium based headless compression screws (Mg‐HCS). Femur and tibia were mounted in a universal uniaxial testing machine (Zwick) simulating a posterior drawer testing, by performing axial load on the femur while the tibia was fixed in 90° flexion. After preconditioning, 500 cycles (200 mm/min) were performed with 10–100 N, followed by load‐to‐failure (LTF). Key parameters measured included stiffness, yield load, LTF and cyclic displacement. Differences were analyzed using an analysis of variance with a significance level of p < 0.05. The macroscopic failure mode was documented.Results: LTF of the intact PCL (1982.0 ± 285.4 N; p ≤ 0.001) significantly exceeded that of all refixations. Whereas LTF of Ti‐CS (1034.8 ± 236.1 N) significantly (p ≤ 0.01) exceeded those of HCS, no significance was seen between titanium (Ti‐HCS: 693.9 ± 220.5 N) or magnesium (Mg‐HCS: 686.7 ± 174.6 N) based HCS. No significant differences were found among the refixation methods regarding cyclic displacement or yield load. Stiffness for the Ti‐CS (144.0 ± 15.4 N/mm), Ti‐HCS (150.0 ± 22.9 N/mm) and Mg‐HCS (170.0 ± 20.9 N/mm) was lower than that of the intact PCL (190.9 ± 8.6 N/mm). Failure modes varied, with the Ti‐CS group showing PCL tears and the HCS groups always experiencing fragment luxation.Conclusion: In our biomechanical model, all fixation techniques demonstrated inferior biomechanical properties compared to the native PCL. Both HCS exhibited similar displacement, stiffness, and yield load values but showed a significantly lower LTF with fragment dislocation compared to conventional screws. Whether this difference is clinically relevant cannot be determined with this model as the porcine model only allows limited transfer into the clinical setting but might limit rehabilitation in the application of HCS in cases of solid avulsion fractures. Further clinical and in vivo studies should be followed to further differentiate the optimized fragment refixation technique.Level of Evidence: There is no level of evidence as this study was an experimental laboratory study.
- 31 March 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (2) , e70225
Open AccessImpact of screw design on refixation of solid avulsion fractures of the posterior cruciate ligament—A biomechanical feasibility study
Purpose: Avulsion fractures of the posterior cruciate ligament (PCL) are commonly treated with refixation. Headless compression screws (HCS) offer benefits, compared to conventional techniques, such as reduced material irritation and option of bioabsorbable materials, possibly avoiding implant removal. Proofing its clinical applicability, the authors hypothesized that (1) biomechanical properties of HCS would be comparable to conventional techniques and (2) magnesium‐based HCS would provide comparable properties to titanium HCS.Study Design: Controlled laboratory study.Methods: Forty fresh frozen porcine knees were dissected keeping the menisci and ligaments intact. A solid avulsion fracture of the tibial PCL (20 mm [length] × 20 mm [width] × 10 mm [depth]) was created with a chisel. Specimens were randomized into four groups: (1) the native PCL, the tibial PCL avulsion refixed with parallel arranged, (2) two 3.5 mm cortical screws with washer (Ti‐CS), (3) two titanium headless compression screws (Ti‐HCS) or (4) two magnesium based headless compression screws (Mg‐HCS). Femur and tibia were mounted in a universal uniaxial testing machine (Zwick) simulating a posterior drawer testing, by performing axial load on the femur while the tibia was fixed in 90° flexion. After preconditioning, 500 cycles (200 mm/min) were performed with 10–100 N, followed by load‐to‐failure (LTF). Key parameters measured included stiffness, yield load, LTF and cyclic displacement. Differences were analyzed using an analysis of variance with a significance level of p < 0.05. The macroscopic failure mode was documented.Results: LTF of the intact PCL (1982.0 ± 285.4 N; p ≤ 0.001) significantly exceeded that of all refixations. Whereas LTF of Ti‐CS (1034.8 ± 236.1 N) significantly (p ≤ 0.01) exceeded those of HCS, no significance was seen between titanium (Ti‐HCS: 693.9 ± 220.5 N) or magnesium (Mg‐HCS: 686.7 ± 174.6 N) based HCS. No significant differences were found among the refixation methods regarding cyclic displacement or yield load. Stiffness for the Ti‐CS (144.0 ± 15.4 N/mm), Ti‐HCS (150.0 ± 22.9 N/mm) and Mg‐HCS (170.0 ± 20.9 N/mm) was lower than that of the intact PCL (190.9 ± 8.6 N/mm). Failure modes varied, with the Ti‐CS group showing PCL tears and the HCS groups always experiencing fragment luxation.Conclusion: In our biomechanical model, all fixation techniques demonstrated inferior biomechanical properties compared to the native PCL. Both HCS exhibited similar displacement, stiffness, and yield load values but showed a significantly lower LTF with fragment dislocation compared to conventional screws. Whether this difference is clinically relevant cannot be determined with this model as the porcine model only allows limited transfer into the clinical setting but might limit rehabilitation in the application of HCS in cases of solid avulsion fractures. Further clinical and in vivo studies should be followed to further differentiate the optimized fragment refixation technique.Level of Evidence: There is no level of evidence as this study was an experimental laboratory study.
- Open Access
- 22 January 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (7) , 2438-2446
Stress radiography of medial knee instability provides a reliable correlation with the severity of injury and medial joint space opening—A robotic biomechanical cadaveric study
Purpose: The medial collateral ligament (MCL), and posterior oblique ligament (POL) are the primary valgus stabilisers of the knee, and clinical examinations in grading valgus instability can be inherently subjective. Stress radiography of medial‐sided knee injuries provides objective diagnosis and was analysed in this study. We hypothesised that (1) medial joint space opening would increase cutting the superficial MCL (sMCL), POL and anterior cruciate ligament (ACL); (2) isolated deep MCL (dMCL) injury would not increase medial joint space opening; (3) medial joint space opening would increase at higher flexion angles.Study Design: Controlled laboratory study.Methods: Ten human cadaveric knees were dissected, preserving ligamentous structures, muscles and fascia. The femur was secured, and the tibia was attached to the six‐degree‐of‐freedom robot. A 10 Nm valgus torque was applied at 0°–45° of flexion and anterior‐posterior (a.p.) radiographs were taken. Sequential sectioning was performed on the dMCL, sMCL, POL and ACL. Medial joint space opening was measured on a.p. radiographs (midpoint technique). Statistical analysis was conducted using a mixed model with post hoc correction (p < 0.05). Intra‐ and interobserver reliability was assessed by calculating the intraclass correlation coefficient (ICC).Results: Medial joint space opening significantly increased with cutting state (p < 0.0001) and flexion angle (p < 0.0001). Although isolated dMCL injury did not significantly increase medial joint space opening, sMCL resection gradually increased joint space opening 3.2 ± 1.9 to 6.9 ± 2.7 mm (p = 0.039) between 0° and 45° knee flexion. Following POL deficiency, medial joint space opening further increased 6.4 ± 2.7 to 11.4 ± 6.2 mm between 0° and 45° knee flexion (p = 0.0035). A combined injury (dMCL/sMCL/POL/ACL) increased medial joint space opening 12.0 ± 4.9 to 21.8 ± 7.9 mm (p < 0.0001) between 0° and 45° knee flexion, compared to the intact state. The intraobserver ICC was 0.995 and the interobserver ICC was 0.955 showing excellent intra‐ and interobserver reliability.Conclusion: Deficiency of the medial stabilisers of the knee increased medial joint space opening in stress radiography, whereas isolated dMCL deficiency did not significantly affect valgus gapping. This study demonstrated a good concordance between valgus stress radiography and clinical scores (International Knee Documentation Committee and Hughston). Our findings support performing valgus stress tests at 0° and at least 20° of flexion.Level of Evidence: There is no level of evidence as this study was an experimental laboratory study.
- 22 January 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (7) , 2438-2446
Open AccessStress radiography of medial knee instability provides a reliable correlation with the severity of injury and medial joint space opening—A robotic biomechanical cadaveric study
Purpose: The medial collateral ligament (MCL), and posterior oblique ligament (POL) are the primary valgus stabilisers of the knee, and clinical examinations in grading valgus instability can be inherently subjective. Stress radiography of medial‐sided knee injuries provides objective diagnosis and was analysed in this study. We hypothesised that (1) medial joint space opening would increase cutting the superficial MCL (sMCL), POL and anterior cruciate ligament (ACL); (2) isolated deep MCL (dMCL) injury would not increase medial joint space opening; (3) medial joint space opening would increase at higher flexion angles.Study Design: Controlled laboratory study.Methods: Ten human cadaveric knees were dissected, preserving ligamentous structures, muscles and fascia. The femur was secured, and the tibia was attached to the six‐degree‐of‐freedom robot. A 10 Nm valgus torque was applied at 0°–45° of flexion and anterior‐posterior (a.p.) radiographs were taken. Sequential sectioning was performed on the dMCL, sMCL, POL and ACL. Medial joint space opening was measured on a.p. radiographs (midpoint technique). Statistical analysis was conducted using a mixed model with post hoc correction (p < 0.05). Intra‐ and interobserver reliability was assessed by calculating the intraclass correlation coefficient (ICC).Results: Medial joint space opening significantly increased with cutting state (p < 0.0001) and flexion angle (p < 0.0001). Although isolated dMCL injury did not significantly increase medial joint space opening, sMCL resection gradually increased joint space opening 3.2 ± 1.9 to 6.9 ± 2.7 mm (p = 0.039) between 0° and 45° knee flexion. Following POL deficiency, medial joint space opening further increased 6.4 ± 2.7 to 11.4 ± 6.2 mm between 0° and 45° knee flexion (p = 0.0035). A combined injury (dMCL/sMCL/POL/ACL) increased medial joint space opening 12.0 ± 4.9 to 21.8 ± 7.9 mm (p < 0.0001) between 0° and 45° knee flexion, compared to the intact state. The intraobserver ICC was 0.995 and the interobserver ICC was 0.955 showing excellent intra‐ and interobserver reliability.Conclusion: Deficiency of the medial stabilisers of the knee increased medial joint space opening in stress radiography, whereas isolated dMCL deficiency did not significantly affect valgus gapping. This study demonstrated a good concordance between valgus stress radiography and clinical scores (International Knee Documentation Committee and Hughston). Our findings support performing valgus stress tests at 0° and at least 20° of flexion.Level of Evidence: There is no level of evidence as this study was an experimental laboratory study.
- Open Access
- 11 September 2024
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (5) , 1586-1593
Combined PCL instabilities cannot be identified using posterior stress radiographs in external or internal rotation: A cadaveric study
Purpose: Posterior stress radiography is recommended to identify isolated or combined posterior cruciate ligament (PCL) deficiencies. The posterior drawer in internal (IR) or external rotation (ER) helps to differentiate between these combined instabilities. The purpose of this study was to evaluate posterior stress radiography (PSR) in isolated and combined PCL deficiency with IR and ER compared to PSR in neutral rotation (NR) for diagnosing combined PCL instabilities.Methods: Six paired fresh‐frozen human cadaveric legs (n = 12) were mounted in a Telos device for PSR. The tibia was rotated using an attached foot apparatus capable of rotating the foot 30° internally and externally. A posterior tibial load of 15 kp (147.1 N) was applied to the tibial tubercle at 90° knee flexion, and a lateral radiograph was obtained. This was repeated with the foot in 30° IR and ER. The PCL, posterolateral complex (PLC), and posteromedial complex (PMC) were sectioned in six knees, while the PMC was sectioned before the PLC in the other six knees. Posterior tibial displacement (PTD) was measured radiographically. Statistical analysis was performed using a two‐way ANOVA and a mixed model with Bonferroni correction, and the significance was set at p < 0.05. Furthermore, intra‐ and interobserver reliability was determined.Results: Cutting the PCL significantly increased the radiographic PTD by 9.8 ± 1.8 mm (side‐to‐side difference compared to the intact state of the knee, n = 12; p < 0.001). This further increased to 12.2 ± 2.3 mm (n = 6; p < 0.01) with an additional PLC deficiency and to 15.4 ± 3.4 mm (n = 6; p < 0.05) with an additional PMC deficiency. A combined PLC and PMC deficiency resulted in an increase of the PTD to 15.9 ± 4.5 mm (n = 12; p < 0.01). In the PCL/PLC deficient state, ER did not demonstrate a higher PTD, compared to the NR and IR posterior drawer. In the PCL/PMC deficient state in IR, PTD was 1.6 ± 0.7 mm (p < 0.01) higher compared to NR and 3.2 ± 1.9 mm (p < 0.05) higher compared to ER. We showed excellent intra‐ and interobserver reliability (0.987–0.997).Conclusion: Combined PCL instabilities resulted in a significant increase in posterior tibial displacement in posterior stress radiographs. However, PSR in IR or ER was unable to differentiate between these combined instabilities. Based on our data, additional stress radiographs in rotation are unlikely to provide any diagnostic benefit in the clinical setting.Level of Evidence: There is no level of evidence as this study was an experimental laboratory study.
- 11 September 2024
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (5) , 1586-1593
Open AccessCombined PCL instabilities cannot be identified using posterior stress radiographs in external or internal rotation: A cadaveric study
Purpose: Posterior stress radiography is recommended to identify isolated or combined posterior cruciate ligament (PCL) deficiencies. The posterior drawer in internal (IR) or external rotation (ER) helps to differentiate between these combined instabilities. The purpose of this study was to evaluate posterior stress radiography (PSR) in isolated and combined PCL deficiency with IR and ER compared to PSR in neutral rotation (NR) for diagnosing combined PCL instabilities.Methods: Six paired fresh‐frozen human cadaveric legs (n = 12) were mounted in a Telos device for PSR. The tibia was rotated using an attached foot apparatus capable of rotating the foot 30° internally and externally. A posterior tibial load of 15 kp (147.1 N) was applied to the tibial tubercle at 90° knee flexion, and a lateral radiograph was obtained. This was repeated with the foot in 30° IR and ER. The PCL, posterolateral complex (PLC), and posteromedial complex (PMC) were sectioned in six knees, while the PMC was sectioned before the PLC in the other six knees. Posterior tibial displacement (PTD) was measured radiographically. Statistical analysis was performed using a two‐way ANOVA and a mixed model with Bonferroni correction, and the significance was set at p < 0.05. Furthermore, intra‐ and interobserver reliability was determined.Results: Cutting the PCL significantly increased the radiographic PTD by 9.8 ± 1.8 mm (side‐to‐side difference compared to the intact state of the knee, n = 12; p < 0.001). This further increased to 12.2 ± 2.3 mm (n = 6; p < 0.01) with an additional PLC deficiency and to 15.4 ± 3.4 mm (n = 6; p < 0.05) with an additional PMC deficiency. A combined PLC and PMC deficiency resulted in an increase of the PTD to 15.9 ± 4.5 mm (n = 12; p < 0.01). In the PCL/PLC deficient state, ER did not demonstrate a higher PTD, compared to the NR and IR posterior drawer. In the PCL/PMC deficient state in IR, PTD was 1.6 ± 0.7 mm (p < 0.01) higher compared to NR and 3.2 ± 1.9 mm (p < 0.05) higher compared to ER. We showed excellent intra‐ and interobserver reliability (0.987–0.997).Conclusion: Combined PCL instabilities resulted in a significant increase in posterior tibial displacement in posterior stress radiographs. However, PSR in IR or ER was unable to differentiate between these combined instabilities. Based on our data, additional stress radiographs in rotation are unlikely to provide any diagnostic benefit in the clinical setting.Level of Evidence: There is no level of evidence as this study was an experimental laboratory study.
- 20 February 2024
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 106 (9) , 809-816
Exposure of Hoffa Fractures Is Improved by Posterolateral and Posteromedial Extensile Approaches
Background: The current literature lacks recommendations regarding surgical approaches to best visualize and reduce Hoffa fractures. The aims of this study were to (1) define surgical corridors to the posterior portions of the lateral and medial femoral condyles and (2) compare the articular surface areas visible with different approaches. Methods: Eight fresh-frozen human cadaveric knees (6 male and 2 female donors; mean age, 68.2 ± 10.2 years) underwent dissection simulating 6 surgical approaches to the distal femur. The visible articular surface areas for each approach were marked using an electrocautery device and subsequently analyzed using image-processing software. The labeled areas of each femoral condyle were statistically compared. Results: At 30° of flexion, visualization of the posterior portions of the lateral and medial femoral condyles was not possible by lateral and medial parapatellar approaches, as only the anterior 29.4% ± 2.1% of the lateral femoral condyle and 25.6% ± 2.8% of the medial condyle were exposed. Visualization of the lateral femoral condyle was limited by the posterolateral ligamentous structures, hence a posterolateral approach only exposed its central (13.1% ± 1.3%) and posterior (12.4% ± 1.1%) portions. Posterolateral extension by an osteotomy of the lateral femoral epicondyle significantly improved the exposure to 53.4% ± 2.7% and, when combined with a Gerdy’s tubercle osteotomy, to 70.9% ± 4.1% (p < 0.001). For the posteromedial approach, an arthrotomy between the anteromedial retinaculum and the superficial medial collateral ligament, and one between the posterior oblique ligament and the medial gastrocnemius tendon, allowed visualization of the central (13.5% ± 2.2%) and the posterior (14.6% ± 2.3%) portions of the medial femoral condyle, while a medial femoral epicondyle osteotomy significantly improved visualization to 66.1% ± 5.5% (p < 0.001). Conclusions: Visualization of the posterior portions of the femoral condyles is limited by the specific anatomy of each surgical corridor. Extension by osteotomy of the femoral epicondyles and Gerdy’s tubercle significantly improved articular surface exposure of the femoral condyles. Clinical Relevance: Knowledge of the surgical approach-specific visualization of the articular surface of the femoral condyles might be helpful to properly reduce small Hoffa fragments.
- 20 February 2024
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 106 (9) , 809-816
Exposure of Hoffa Fractures Is Improved by Posterolateral and Posteromedial Extensile Approaches
Background: The current literature lacks recommendations regarding surgical approaches to best visualize and reduce Hoffa fractures. The aims of this study were to (1) define surgical corridors to the posterior portions of the lateral and medial femoral condyles and (2) compare the articular surface areas visible with different approaches. Methods: Eight fresh-frozen human cadaveric knees (6 male and 2 female donors; mean age, 68.2 ± 10.2 years) underwent dissection simulating 6 surgical approaches to the distal femur. The visible articular surface areas for each approach were marked using an electrocautery device and subsequently analyzed using image-processing software. The labeled areas of each femoral condyle were statistically compared. Results: At 30° of flexion, visualization of the posterior portions of the lateral and medial femoral condyles was not possible by lateral and medial parapatellar approaches, as only the anterior 29.4% ± 2.1% of the lateral femoral condyle and 25.6% ± 2.8% of the medial condyle were exposed. Visualization of the lateral femoral condyle was limited by the posterolateral ligamentous structures, hence a posterolateral approach only exposed its central (13.1% ± 1.3%) and posterior (12.4% ± 1.1%) portions. Posterolateral extension by an osteotomy of the lateral femoral epicondyle significantly improved the exposure to 53.4% ± 2.7% and, when combined with a Gerdy’s tubercle osteotomy, to 70.9% ± 4.1% (p < 0.001). For the posteromedial approach, an arthrotomy between the anteromedial retinaculum and the superficial medial collateral ligament, and one between the posterior oblique ligament and the medial gastrocnemius tendon, allowed visualization of the central (13.5% ± 2.2%) and the posterior (14.6% ± 2.3%) portions of the medial femoral condyle, while a medial femoral epicondyle osteotomy significantly improved visualization to 66.1% ± 5.5% (p < 0.001). Conclusions: Visualization of the posterior portions of the femoral condyles is limited by the specific anatomy of each surgical corridor. Extension by osteotomy of the femoral epicondyles and Gerdy’s tubercle significantly improved articular surface exposure of the femoral condyles. Clinical Relevance: Knowledge of the surgical approach-specific visualization of the articular surface of the femoral condyles might be helpful to properly reduce small Hoffa fragments.
- Open Access
- 9 July 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (14) , 4567
Recurrent Instability Rate and Subjective Knee Function following Accelerated Rehabilitation after ACL Reconstruction in Comparison to a Conservative Rehabilitation Protocol
Introduction: The Purpose of the present study was to assess the outcome of anterior cruciate ligament reconstruction (ACLR) with an accelerated rehabilitation protocol and to compare it to a conservative rehabilitation protocol. It was hypothesized that an accelerated rehabilitation protocol, including brace-free early weight bearing, would result in a higher rate of recurrent instability and revision surgery compared to a conservative rehabilitation protocol. Methods: From 2016 to 2017, two different rehabilitation protocols for isolated ACLR were used at a high-volume knee surgery center. A total of 65 consecutive patients with isolated hamstring ACLR, of whom n = 33 had been treated with an accelerated (AccRehab) and n = 32 with a conservative rehabilitation protocol (ConRehab), were retrospectively included in the study. Patients were evaluated for recurrent instability, revision surgery, and other complications at a mean follow-up period of 64 ± 7.4 months. In addition, Tegner Activity Scale, Lysholm Score, and IKDC-subjective Score were evaluated. Statistical comparison between the two groups was performed utilizing Fisher’s exact test and Student’s t-test. Results: Mean age (29.3 vs. 26.6 years) and preoperative Tegner Score (6.4 vs. 5.9) were comparable between both groups. At 64 ± 7.4 months after ACLR, six cases of recurrent instability were reported in the AccRehab group (18%) in comparison to three cases (9%) in the ConRehab group (p = n.s.). There was no significant difference regarding revision surgery and further complications. Furthermore, no significant difference was found between both groups regarding Tegner (5.5 ± 1.9 vs. 5.5 ± 1.2), Lysholm (93.6 ± 6.3 vs. 89.3 ± 10.7), and IKDC score (89.7 ± 7.9 vs. 86.7 ± 12.1). Conclusion: No significant disadvantage of an accelerated rehabilitation protocol following ACLR was found in terms of recurrent instability rate, revision surgery, or patient-reported outcome. However, a trend towards a higher reinstability rate was found for an accelerated rehabilitation protocol. Future level one trials evaluating brace-free early weight bearing following ACLR are desirable.
- 9 July 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (14) , 4567
Open AccessRecurrent Instability Rate and Subjective Knee Function following Accelerated Rehabilitation after ACL Reconstruction in Comparison to a Conservative Rehabilitation Protocol
Introduction: The Purpose of the present study was to assess the outcome of anterior cruciate ligament reconstruction (ACLR) with an accelerated rehabilitation protocol and to compare it to a conservative rehabilitation protocol. It was hypothesized that an accelerated rehabilitation protocol, including brace-free early weight bearing, would result in a higher rate of recurrent instability and revision surgery compared to a conservative rehabilitation protocol. Methods: From 2016 to 2017, two different rehabilitation protocols for isolated ACLR were used at a high-volume knee surgery center. A total of 65 consecutive patients with isolated hamstring ACLR, of whom n = 33 had been treated with an accelerated (AccRehab) and n = 32 with a conservative rehabilitation protocol (ConRehab), were retrospectively included in the study. Patients were evaluated for recurrent instability, revision surgery, and other complications at a mean follow-up period of 64 ± 7.4 months. In addition, Tegner Activity Scale, Lysholm Score, and IKDC-subjective Score were evaluated. Statistical comparison between the two groups was performed utilizing Fisher’s exact test and Student’s t-test. Results: Mean age (29.3 vs. 26.6 years) and preoperative Tegner Score (6.4 vs. 5.9) were comparable between both groups. At 64 ± 7.4 months after ACLR, six cases of recurrent instability were reported in the AccRehab group (18%) in comparison to three cases (9%) in the ConRehab group (p = n.s.). There was no significant difference regarding revision surgery and further complications. Furthermore, no significant difference was found between both groups regarding Tegner (5.5 ± 1.9 vs. 5.5 ± 1.2), Lysholm (93.6 ± 6.3 vs. 89.3 ± 10.7), and IKDC score (89.7 ± 7.9 vs. 86.7 ± 12.1). Conclusion: No significant disadvantage of an accelerated rehabilitation protocol following ACLR was found in terms of recurrent instability rate, revision surgery, or patient-reported outcome. However, a trend towards a higher reinstability rate was found for an accelerated rehabilitation protocol. Future level one trials evaluating brace-free early weight bearing following ACLR are desirable.
- Open Access
Refixation of a Large Osteochondral Fragment with Magnesium Compression Screws—A Case Report
Introduction: Osteochondrosis dissecans (OCD) is a disease affecting the subchondral bone and the overlying articular cartilage. The etiology is most likely a combination of biological and mechanical factors. The incidence is highest in children >12 years old and it predominantly affects the knee. In high-grade OCD lesions, free osteochondral fragments usually are refixed via titanium screws or biodegradable screws or pins. In this case, headless compression screws made from magnesium were used for refixation. Case report: A thirteen-year-old female patient with a two-year history of knee pain was diagnosed with an OCD lesion of the medial femoral condyle. After initial conservative treatment, displacement of the osteochondral fragment occurred. Refixation was performed using two headless magnesium compression screws. At the 6 months follow up, the patient was pain free, and the fragment showed progressive healing while the implants were biodegrading. Discussion: Existing implants for refixation of OCD lesions either require subsequent removal or show less stability and possible inflammatory reactions. The new generation of magnesium screws used in this case did not lead to a gas release, as described for previous magnesium implants, while maintaining stability during continuous biodegradation. Conclusions: The data available to date on magnesium implants for the treatment of OCD are promising. However, the evidence on the magnesium implants in refixation surgery of OCD lesions is still limited. Further research needs to be conducted to provide data on outcomes and possible complications.
Open AccessRefixation of a Large Osteochondral Fragment with Magnesium Compression Screws—A Case Report
Introduction: Osteochondrosis dissecans (OCD) is a disease affecting the subchondral bone and the overlying articular cartilage. The etiology is most likely a combination of biological and mechanical factors. The incidence is highest in children >12 years old and it predominantly affects the knee. In high-grade OCD lesions, free osteochondral fragments usually are refixed via titanium screws or biodegradable screws or pins. In this case, headless compression screws made from magnesium were used for refixation. Case report: A thirteen-year-old female patient with a two-year history of knee pain was diagnosed with an OCD lesion of the medial femoral condyle. After initial conservative treatment, displacement of the osteochondral fragment occurred. Refixation was performed using two headless magnesium compression screws. At the 6 months follow up, the patient was pain free, and the fragment showed progressive healing while the implants were biodegrading. Discussion: Existing implants for refixation of OCD lesions either require subsequent removal or show less stability and possible inflammatory reactions. The new generation of magnesium screws used in this case did not lead to a gas release, as described for previous magnesium implants, while maintaining stability during continuous biodegradation. Conclusions: The data available to date on magnesium implants for the treatment of OCD are promising. However, the evidence on the magnesium implants in refixation surgery of OCD lesions is still limited. Further research needs to be conducted to provide data on outcomes and possible complications.
- 11 June 2020
- Published by Elsevier in Sports Orthopaedics and Traumatology
- Vol. 36 (2) , 201
Längenveränderungen der posterolateralen Gelenkecke des Kniegelenks: Können aktuelle Rekonstruktionstechniken die Anatomie nachbilden?
- 11 June 2020
- Published by Elsevier in Sports Orthopaedics and Traumatology
- Vol. 36 (2) , 201
Längenveränderungen der posterolateralen Gelenkecke des Kniegelenks: Können aktuelle Rekonstruktionstechniken die Anatomie nachbilden?