The interdependence of targets for continuous glucose monitoring outcomes in type 1 diabetes with automated insulin delivery
Open Access
- 26 September 2024
- journal article
- research article
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 26 (12) , 5836-5844
Abstract
Aim: The aim was to determine the interdependence of targets for glucose management indicator (GMI), time within the ranges of 70–180 mg/dL (TIR) and 70–140 mg/dL (time in tight glucose range [TITR]), time above 180 mg/dL (TA180) and 250 mg/dL (TA250) and time below 70 mg/dL (TB70) and 54 mg/dL (TB54) and its implications for setting targets in automated insulin delivery (AID). Materials and Methods: Real‐world data from individuals with type 1 diabetes using the 780G system were used to calculate the receiver operating characteristic curves and establish interdependent targets for time in ranges based on several GMI benchmarks. Correlation, regression and principal component analysis were used to determine their association and dimensionality. Results: In individuals aged >15 years ( n = 41 692), a GMI 81%, >58%, 81% of the variability in the remaining continuous glucose monitoring (CGM) metrics, providing accurate predictions. Individuals aged ≤15 years ( n = 14 459) showed similar results. Conclusion: We developed a methodology to establish interdependent CGM targets for therapies with CGM data outputs. In AID with the 780G system, a GMI <7% requires time in ranges close to consensus targets. Targets for GMI, TIR, TITR, TA180 and TA250 could be reduced to targets for GMI or TIR, whereas targets for time in hypoglycaemia are not inherently tied to GMI/TIR targets.Keywords
Funding Information
- Medtronic Europe
This publication has 15 references indexed in Scilit:
- MiniMed 780G System Outperforms Other Automated Insulin Systems Due to Algorithm Design, Not Bias: Response to Inaccurate AllegationsDiabetes Technology & Therapeutics, 2024
- Celebrating the Data from 100,000 Real-World Users of the MiniMed™ 780G System in Europe, Middle East, and Africa Collected Over 3 Years: From Data to Clinical EvidenceDiabetes Technology & Therapeutics, 2024
- A Peek Under the Hood: Explaining the MiniMed™ 780G Algorithm with Meal Detection TechnologyDiabetes Technology & Therapeutics, 2024
- Early Real-World Performance of the MiniMed™ 780G Advanced Hybrid Closed-Loop System and Recommended Settings Use in the United StatesDiabetes Technology & Therapeutics, 2024
- Future of Time-in-Range Goals in the Era of Advanced Hybrid Closed-Loop Automated Insulin Delivery SystemsDiabetes Technology & Therapeutics, 2024
- Essential Continuous Glucose Monitoring Metrics: The Principal Dimensions of Glycemic Control in DiabetesDiabetes Technology & Therapeutics, 2022
- Real-World Performance of the MiniMed™ 780G System: First Report of Outcomes from 4120 UsersDiabetes Technology & Therapeutics, 2022
- Improving Transparency to Build Trust in Real-World Secondary Data Studies for Hypothesis Testing—Why, What, and How: Recommendations and a Road Map from the Real-World Evidence Transparency InitiativeValue in Health, 2020
- Glucose Variability Indices in Type 1 Diabetes: Parsimonious Set of Indices Revealed by Sparse Principal Component AnalysisDiabetes Technology & Therapeutics, 2014
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusThe New England journal of medicine, 1993