Javier Castañeda
Research Subjects
Javier Castañeda has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Ohad Cohen
Division of Endocrinology, Diabetes and Metabolism, Sheba Medical Center, Tel-Hashomer, Israel
10 shared publications - Tim van Den Heuvel
Medtronic International Trading Sàrl Tolochenaz Switzerland
6 shared publications Arcelia Arrieta
Medtronic International Trading Sàrl Tolochenaz Switzerland
3 shared publications- Arcelia Arrieta
Medtronic Diabetes, Medtronic International Trading Sàrl, Tolochenaz, Switzerland
3 shared publications - Isabeau Thijs
Medtronic Diabetes, Medtronic International Trading Sàrl Tolochenaz Switzerland
3 shared publications John Shin
Medtronic Diabetes, Medtronic International Trading Sàrl, Tolochenaz, Switzerland
3 shared publications
Latest Publications
- 15 July 2026
- Published by SAGE Publications in Diabetes Technology & Therapeutics
Use of Low-Glucose Alerts and Their Impact on Continuous Glucose Monitoring Outcomes in Real-World Use of the MiniMed 780G System.
Hypoglycemia remains a major concern in insulin therapy and has limited intensive glycemic control. Although automated insulin delivery substantially reduces hypoglycemia risk, relatively high low-glucose alert (LA) thresholds (LGAT) remain commonly used. This study evaluated the impact of user-set LGAT on glycemic outcomes. This retrospective cohort study analyzed anonymized real-world data from 169,487 MiniMed 780G users with type 1 diabetes across Europe, the Middle East, and Africa (August 1, 2024-July 31, 2025). Use of LAs, user-set thresholds, and glycemic metrics was evaluated. Most users (96%) enabled LGAT, and 36% enabled predictive LGAT. Median, 25th and 75th percentiles of time below 54 and 70 mg/dL remained low and within recommended targets across all alert thresholds overall, in users aged ≤15 years, and overnight. Hypoglycemia targets were achieved by >82% and >90% of users with thresholds <60 and ≥60 mg/dL, respectively. In contrast, time in range (TIR) 70-180 mg/dL and hyperglycemia targets were more frequently achieved with LGAT <60 mg/dL, with 70% and 61% meeting these targets, respectively. Overall, 43% of users with LGAT 80 mg/dL. A LGAT below 60 mg/dL is generally recommended, as it is associated with increased TIR, reduced hyperglycemia, and low time in hypoglycemia. A threshold between 60 and 70 mg/dL may provide a balanced option for those with greater hypoglycemia concerns. These recommendations can optimize system usability and glycemic outcomes while maintaining safety and minimizing alarm burden.
- 15 July 2026
- Published by SAGE Publications in Diabetes Technology & Therapeutics
Use of Low-Glucose Alerts and Their Impact on Continuous Glucose Monitoring Outcomes in Real-World Use of the MiniMed 780G System.
Hypoglycemia remains a major concern in insulin therapy and has limited intensive glycemic control. Although automated insulin delivery substantially reduces hypoglycemia risk, relatively high low-glucose alert (LA) thresholds (LGAT) remain commonly used. This study evaluated the impact of user-set LGAT on glycemic outcomes. This retrospective cohort study analyzed anonymized real-world data from 169,487 MiniMed 780G users with type 1 diabetes across Europe, the Middle East, and Africa (August 1, 2024-July 31, 2025). Use of LAs, user-set thresholds, and glycemic metrics was evaluated. Most users (96%) enabled LGAT, and 36% enabled predictive LGAT. Median, 25th and 75th percentiles of time below 54 and 70 mg/dL remained low and within recommended targets across all alert thresholds overall, in users aged ≤15 years, and overnight. Hypoglycemia targets were achieved by >82% and >90% of users with thresholds <60 and ≥60 mg/dL, respectively. In contrast, time in range (TIR) 70-180 mg/dL and hyperglycemia targets were more frequently achieved with LGAT <60 mg/dL, with 70% and 61% meeting these targets, respectively. Overall, 43% of users with LGAT 80 mg/dL. A LGAT below 60 mg/dL is generally recommended, as it is associated with increased TIR, reduced hyperglycemia, and low time in hypoglycemia. A threshold between 60 and 70 mg/dL may provide a balanced option for those with greater hypoglycemia concerns. These recommendations can optimize system usability and glycemic outcomes while maintaining safety and minimizing alarm burden.
- Open Access
- 2 January 2026
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 28 (S1) , 35-48
Challenges in glycaemic control among women with type 1 diabetes and the role of MiniMed 780G system: A narrative review
Sex‐based disparities in the incidence, prevalence and disease manifestations have been observed across various medical conditions, including type 1 diabetes (T1D). Differences in glycaemic control and quality of life between men and women have been reported, with women experiencing lower rates of glycaemic targets and a higher risk for long‐term complications, particularly cardiovascular disease. Additionally, women face a greater economic and mental health burden related to T1D. This narrative review explores the challenges that complicate glycaemic management in women living with T1D, including hormonal influences during puberty, pregnancy and the (peri‐) menopausal period. We also summarize current available evidence on the safety and efficacy of the MiniMed™ 780G (MM780G) system in addressing these challenges for women living with T1D. Finally, recent real‐world data are reported on the absence of significant sex‐related differences in glycaemic outcomes of over 280 000 real‐world users of the MM780G, across various age groups from childhood and adolescence to the (peri‐) menopausal period.
- 2 January 2026
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 28 (S1) , 35-48
Open AccessChallenges in glycaemic control among women with type 1 diabetes and the role of MiniMed 780G system: A narrative review
Sex‐based disparities in the incidence, prevalence and disease manifestations have been observed across various medical conditions, including type 1 diabetes (T1D). Differences in glycaemic control and quality of life between men and women have been reported, with women experiencing lower rates of glycaemic targets and a higher risk for long‐term complications, particularly cardiovascular disease. Additionally, women face a greater economic and mental health burden related to T1D. This narrative review explores the challenges that complicate glycaemic management in women living with T1D, including hormonal influences during puberty, pregnancy and the (peri‐) menopausal period. We also summarize current available evidence on the safety and efficacy of the MiniMed™ 780G (MM780G) system in addressing these challenges for women living with T1D. Finally, recent real‐world data are reported on the absence of significant sex‐related differences in glycaemic outcomes of over 280 000 real‐world users of the MM780G, across various age groups from childhood and adolescence to the (peri‐) menopausal period.
- Open Access
- 28 December 2025
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 28 (3) , 2473-2476
What is the impact of an advanced hybrid closed‐loop system on weight control among people with type 1 diabetes?
- 28 December 2025
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 28 (3) , 2473-2476
Open AccessWhat is the impact of an advanced hybrid closed‐loop system on weight control among people with type 1 diabetes?
- 5 June 2025
- Published by Springer Nature in Acta Diabetologica
- Vol. 62 (11) , 1953-1957
Use of the temporary glycemic target feature in the medtronic MiniMed™ 780G advanced hybrid closed loop system: a real-world evidence study
Aim The MiniMed™ 780G system utilizes an Advanced Hybrid Closed-Loop algorithm, which is optimized to perform best at a glucose target of 100 mg/dL. The system also includes a temporary target feature (TT) of 150 mg/dL that can be set when higher glucose utilization is anticipated (e.g., exercise/strenuous work). Methods Real-world data from 1002 randomly selected users of the MiniMed™ 780G and MiniMed™ 670G systems were used to investigate the TT functionality (n = 501 MiniMed™ 780G users, n = 501 MiniMed™ 670G users). Continuous glucose monitoring (CGM) metrics were calculated for 4-h intervals (4 h prior to commencing TT use and 0–4, 4–8, 8–12, 12–16, 16–20 and 20–24 h after TT initiation). Results CGM results showed that, with both systems, the time-in-range (TIR) during TT periods mostly equalled or exceeded TIR in corresponding non-TT periods. In the first 4 h after TT initiation, the MiniMed™ 780G system demonstrated a TIR and time in tight range (TITR) of 71.6% and 46.4%, respectively, [a 1.6 (p = 0.11) and 2.6 (p = 0.009) percentage point benefit in TIR and TITR, respectively, versus the 670G system]. Mean time-below-range remained below target in both periods. Conclusions These findings confirm that the TT setting performs as intended, allowing users to maintain TIR during strenuous activity without compromising safety.
- 5 June 2025
- Published by Springer Nature in Acta Diabetologica
- Vol. 62 (11) , 1953-1957
Use of the temporary glycemic target feature in the medtronic MiniMed™ 780G advanced hybrid closed loop system: a real-world evidence study
Aim The MiniMed™ 780G system utilizes an Advanced Hybrid Closed-Loop algorithm, which is optimized to perform best at a glucose target of 100 mg/dL. The system also includes a temporary target feature (TT) of 150 mg/dL that can be set when higher glucose utilization is anticipated (e.g., exercise/strenuous work). Methods Real-world data from 1002 randomly selected users of the MiniMed™ 780G and MiniMed™ 670G systems were used to investigate the TT functionality (n = 501 MiniMed™ 780G users, n = 501 MiniMed™ 670G users). Continuous glucose monitoring (CGM) metrics were calculated for 4-h intervals (4 h prior to commencing TT use and 0–4, 4–8, 8–12, 12–16, 16–20 and 20–24 h after TT initiation). Results CGM results showed that, with both systems, the time-in-range (TIR) during TT periods mostly equalled or exceeded TIR in corresponding non-TT periods. In the first 4 h after TT initiation, the MiniMed™ 780G system demonstrated a TIR and time in tight range (TITR) of 71.6% and 46.4%, respectively, [a 1.6 (p = 0.11) and 2.6 (p = 0.009) percentage point benefit in TIR and TITR, respectively, versus the 670G system]. Mean time-below-range remained below target in both periods. Conclusions These findings confirm that the TT setting performs as intended, allowing users to maintain TIR during strenuous activity without compromising safety.
- 12 March 2025
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 20 (4) , 1302-1310
Performance of an Automated Insulin Delivery System in People Living With Type 2 Diabetes and Insulin Resistance: First Real-World Evidence in 26,427 Users
Background: Type 2 diabetes (T2D) is a phenotypically heterogeneous disease. The use of insulin is required in a significant portion of people with T2D, despite recent developments in antidiabetic medications. This study analyzes glycemic outcomes in automated insulin delivery (AID) users with T2D with different insulin requirements. Methods: This is a retrospective, real-world analysis including MiniMed 780G (MM780G) data uploaded to CareLink Personal (January 2020 to April 2024). Four cohorts were identified based on phenotypes of T2D: (A) users with total daily dose of insulin (TDD) ≥ 100 IU, (B) users with self-reported T2D, (C) users with self-reported T2D and TDD ≥ 100 IU, and (D) users with self-reported T2D and TDD <100 IU. Glycemic outcomes and insulin use were assessed post-AID, pre-AID versus post-AID, and six-month longitudinal post-AID. Results: A total of 26 427 users were included in this study, of which 18 466 in cohort A, 10 795 in cohort B, 2 834 in cohort C, and 7 961 in cohort D. Mean time in range (TIR) was 71.1% ± 12.2 for cohort A, 75.1% ±14.1 for cohort B, 72.2% ± 15.0 for cohort C, and 76.1% ± 13.6 for cohort D. Mean time below range (TBR) <70 mg/dL was ≤1% in all cohorts. The users in cohort C using the recommended optimal settings (glucose target [GT] of 100 mg/dL and active insulin time [AIT] of two hours) had a greater TIR with 78.7% ± 10.8. All cohorts increased ≥10% post-AID compared with pre-AID. Conclusions: The use of this AID is associated with effective therapy outcomes, as indicated by over 70% TIR, and appears to be safe, as demonstrated by a low TBR in a large cohort of real-life users with self-reported T2D and high or low TDD.
- 12 March 2025
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 20 (4) , 1302-1310
Performance of an Automated Insulin Delivery System in People Living With Type 2 Diabetes and Insulin Resistance: First Real-World Evidence in 26,427 Users
Background: Type 2 diabetes (T2D) is a phenotypically heterogeneous disease. The use of insulin is required in a significant portion of people with T2D, despite recent developments in antidiabetic medications. This study analyzes glycemic outcomes in automated insulin delivery (AID) users with T2D with different insulin requirements. Methods: This is a retrospective, real-world analysis including MiniMed 780G (MM780G) data uploaded to CareLink Personal (January 2020 to April 2024). Four cohorts were identified based on phenotypes of T2D: (A) users with total daily dose of insulin (TDD) ≥ 100 IU, (B) users with self-reported T2D, (C) users with self-reported T2D and TDD ≥ 100 IU, and (D) users with self-reported T2D and TDD <100 IU. Glycemic outcomes and insulin use were assessed post-AID, pre-AID versus post-AID, and six-month longitudinal post-AID. Results: A total of 26 427 users were included in this study, of which 18 466 in cohort A, 10 795 in cohort B, 2 834 in cohort C, and 7 961 in cohort D. Mean time in range (TIR) was 71.1% ± 12.2 for cohort A, 75.1% ±14.1 for cohort B, 72.2% ± 15.0 for cohort C, and 76.1% ± 13.6 for cohort D. Mean time below range (TBR) <70 mg/dL was ≤1% in all cohorts. The users in cohort C using the recommended optimal settings (glucose target [GT] of 100 mg/dL and active insulin time [AIT] of two hours) had a greater TIR with 78.7% ± 10.8. All cohorts increased ≥10% post-AID compared with pre-AID. Conclusions: The use of this AID is associated with effective therapy outcomes, as indicated by over 70% TIR, and appears to be safe, as demonstrated by a low TBR in a large cohort of real-life users with self-reported T2D and high or low TDD.
- Open Access
- 4 February 2025
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 27 (4) , 2242-2250
MiniMed 780G system performance in older users with type 1 diabetes: Real‐world evidence and the case for stricter glycaemic targets
Aims: Large‐scale studies on the effectiveness of automated insulin delivery (AID) systems in older people with type 1 diabetes are still limited. A multinational, retrospective, real‐world study was conducted to examine the performance of the MiniMed™ 780G advanced hybrid closed‐loop system in users with type 1 diabetes aged ≥56 years compared with those aged 16–55 years. Materials and Methods: Data from 35 366 MiniMed™ 780G system users aged 16–55 years and 7415 users aged ≥56 years were included. The main outcome was time in range 70–180 mg/dL (TIR); other continuous glucose monitoring (CGM) metrics were also assessed. Results: Across all users, mean TIR was 77.1% for users aged ≥56 years and 73.1% for those aged 16–55 years (Δ4.0, 95% confidence interval [CI]: 3.8–4.2, p p <0.0001). Across all users, mean time below range 70% without increasing hypoglycaemia risk. Users employing optimal settings showed the best outcomes. The system performed as well as or better than in younger users. These findings support the case that more stringent TIR targets can be achieved safely.
- 4 February 2025
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 27 (4) , 2242-2250
Open AccessMiniMed 780G system performance in older users with type 1 diabetes: Real‐world evidence and the case for stricter glycaemic targets
Aims: Large‐scale studies on the effectiveness of automated insulin delivery (AID) systems in older people with type 1 diabetes are still limited. A multinational, retrospective, real‐world study was conducted to examine the performance of the MiniMed™ 780G advanced hybrid closed‐loop system in users with type 1 diabetes aged ≥56 years compared with those aged 16–55 years. Materials and Methods: Data from 35 366 MiniMed™ 780G system users aged 16–55 years and 7415 users aged ≥56 years were included. The main outcome was time in range 70–180 mg/dL (TIR); other continuous glucose monitoring (CGM) metrics were also assessed. Results: Across all users, mean TIR was 77.1% for users aged ≥56 years and 73.1% for those aged 16–55 years (Δ4.0, 95% confidence interval [CI]: 3.8–4.2, p p <0.0001). Across all users, mean time below range 70% without increasing hypoglycaemia risk. Users employing optimal settings showed the best outcomes. The system performed as well as or better than in younger users. These findings support the case that more stringent TIR targets can be achieved safely.
- Open Access
- 4 October 2024
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 26 (10) , 783-784
MiniMed 780G System Outperforms Other Automated Insulin Systems Due to Algorithm Design, Not Bias: Response to Inaccurate Allegations
Not applicable (letter to the editor).
- 4 October 2024
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 26 (10) , 783-784
Open AccessMiniMed 780G System Outperforms Other Automated Insulin Systems Due to Algorithm Design, Not Bias: Response to Inaccurate Allegations
Not applicable (letter to the editor).
- Open Access
- 26 September 2024
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 26 (12) , 5836-5844
The interdependence of targets for continuous glucose monitoring outcomes in type 1 diabetes with automated insulin delivery
Aim: The aim was to determine the interdependence of targets for glucose management indicator (GMI), time within the ranges of 70–180 mg/dL (TIR) and 70–140 mg/dL (time in tight glucose range [TITR]), time above 180 mg/dL (TA180) and 250 mg/dL (TA250) and time below 70 mg/dL (TB70) and 54 mg/dL (TB54) and its implications for setting targets in automated insulin delivery (AID). Materials and Methods: Real‐world data from individuals with type 1 diabetes using the 780G system were used to calculate the receiver operating characteristic curves and establish interdependent targets for time in ranges based on several GMI benchmarks. Correlation, regression and principal component analysis were used to determine their association and dimensionality. Results: In individuals aged >15 years ( n = 41 692), a GMI 81%, >58%, 81% of the variability in the remaining continuous glucose monitoring (CGM) metrics, providing accurate predictions. Individuals aged ≤15 years ( n = 14 459) showed similar results. Conclusion: We developed a methodology to establish interdependent CGM targets for therapies with CGM data outputs. In AID with the 780G system, a GMI <7% requires time in ranges close to consensus targets. Targets for GMI, TIR, TITR, TA180 and TA250 could be reduced to targets for GMI or TIR, whereas targets for time in hypoglycaemia are not inherently tied to GMI/TIR targets.
- 26 September 2024
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 26 (12) , 5836-5844
Open AccessThe interdependence of targets for continuous glucose monitoring outcomes in type 1 diabetes with automated insulin delivery
Aim: The aim was to determine the interdependence of targets for glucose management indicator (GMI), time within the ranges of 70–180 mg/dL (TIR) and 70–140 mg/dL (time in tight glucose range [TITR]), time above 180 mg/dL (TA180) and 250 mg/dL (TA250) and time below 70 mg/dL (TB70) and 54 mg/dL (TB54) and its implications for setting targets in automated insulin delivery (AID). Materials and Methods: Real‐world data from individuals with type 1 diabetes using the 780G system were used to calculate the receiver operating characteristic curves and establish interdependent targets for time in ranges based on several GMI benchmarks. Correlation, regression and principal component analysis were used to determine their association and dimensionality. Results: In individuals aged >15 years ( n = 41 692), a GMI 81%, >58%, 81% of the variability in the remaining continuous glucose monitoring (CGM) metrics, providing accurate predictions. Individuals aged ≤15 years ( n = 14 459) showed similar results. Conclusion: We developed a methodology to establish interdependent CGM targets for therapies with CGM data outputs. In AID with the 780G system, a GMI <7% requires time in ranges close to consensus targets. Targets for GMI, TIR, TITR, TA180 and TA250 could be reduced to targets for GMI or TIR, whereas targets for time in hypoglycaemia are not inherently tied to GMI/TIR targets.
- Open Access
- 29 May 2023
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 25 (9) , 2545-2552
The significance of coefficient of variation as a measure of hypoglycaemia risk and glycaemic control in real world users of the automated insulin delivery MiniMed 780G system
Aim: Use of the MiniMed 780G system (MM780G) can result in a reduction in mean and standard deviation (SD) of sensor glucose (SG) values. We assessed the significance of the coefficient of variation (CV) as a measure of hypoglycaemia risk and glycaemic control. Materials and Methods: Data from 10 404 MM780G users were analysed using multivariable logistic regression to assess the contribution of CV to (a) hypoglycaemia risk, measured as not reaching target 70% and glucose management indicator <7%. CV was compared with SD and low blood glucose index. To assess the relevance of CV <36% as a therapeutic threshold, we identified the CV cut‐off point that optimally discriminated users at risk of hypoglycaemia. Results: The contribution of CV was the smallest in terms of risk of hypoglycaemia (vs. low blood glucose index and SD) and TIR and glucose management indicator targets (vs. SD). In all cases the models with SD showed the best fit. A CV <43.4% (95% CI: 42.9–43.9) was the optimal cut‐off point with a correct classification rate of 87.2% (vs. 72.9% for CV <36%). Conclusion: For MM780G users, CV is a poor marker for hypoglycaemia risk and glycaemic control. We recommend using, for the former, TBR and whether the TBR target is met (and not using CV <36% as a therapeutic threshold for hypoglycaemia); for the latter, TIR, time above range, whether targets are met and a discrete description of mean SG and SD of SG values.
- 29 May 2023
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 25 (9) , 2545-2552
Open AccessThe significance of coefficient of variation as a measure of hypoglycaemia risk and glycaemic control in real world users of the automated insulin delivery MiniMed 780G system
Aim: Use of the MiniMed 780G system (MM780G) can result in a reduction in mean and standard deviation (SD) of sensor glucose (SG) values. We assessed the significance of the coefficient of variation (CV) as a measure of hypoglycaemia risk and glycaemic control. Materials and Methods: Data from 10 404 MM780G users were analysed using multivariable logistic regression to assess the contribution of CV to (a) hypoglycaemia risk, measured as not reaching target 70% and glucose management indicator <7%. CV was compared with SD and low blood glucose index. To assess the relevance of CV <36% as a therapeutic threshold, we identified the CV cut‐off point that optimally discriminated users at risk of hypoglycaemia. Results: The contribution of CV was the smallest in terms of risk of hypoglycaemia (vs. low blood glucose index and SD) and TIR and glucose management indicator targets (vs. SD). In all cases the models with SD showed the best fit. A CV <43.4% (95% CI: 42.9–43.9) was the optimal cut‐off point with a correct classification rate of 87.2% (vs. 72.9% for CV <36%). Conclusion: For MM780G users, CV is a poor marker for hypoglycaemia risk and glycaemic control. We recommend using, for the former, TBR and whether the TBR target is met (and not using CV <36% as a therapeutic threshold for hypoglycaemia); for the latter, TIR, time above range, whether targets are met and a discrete description of mean SG and SD of SG values.