This paper presents an out-of-step protection algorithm based on angle derivatives, which makes use of wide-area measurements and can be applied on arbitrary tie-lines in electrical power systems. The developed algorithm uses PMU measurements that are taken at both ends of a transmission line. Based on the changes of the electrical quantities in the power system, the algorithm detects unstable system conditions. Thus, the developed solution is settingless and can be easily applied where an out-of-step condition is expected. The concept is deployed by using an industrial controller and tested by conducting numerous hardware-in-the-loop simulations. Additionally, recorded data from actual out-of-step events in the Icelandic power system are used to validate the developed algorithm. The performance of the implemented method is compared against the traditional impedance-based out-of-step protection methods. The results confirm that the proposed algorithm detects out-of-step conditions more reliably and faster than the traditional impedance-based solutions.Keywords
Funding Information
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (NWO) through the Take-Off Project “Power swing detection and prevention in future networks with high penetration of renewable energy,” (19279)
This publication has 27 references indexed in Scilit:
- Generator Out-of-Step Prediction Based on Faster-Than-Real-Time Analysis: Concepts and ApplicationsIEEE Transactions on Power Systems, 2017
- On-line determination of transient stability status using MLPNN2017
- Dynamic State Estimation Assisted Out-of-Step Detection for Generators Using Angular DifferenceIEEE Transactions on Power Delivery, 2016
- A Novel Out-of-step Splitting Protection Based on the Wide Area InformationIEEE Transactions on Smart Grid, 2016
- A Predictive Generator Out-of-Step Protection and Transient Stability Monitoring Scheme Enabled by a Distributed Dynamic State EstimatorIEEE Transactions on Power Delivery, 2015
- New support vector machine‐based digital relaying scheme for discrimination between power swing and faultIET Generation, Transmission & Distribution, 2014
- Application of Equal Area Criterion Conditions in the Time Domain for Out-of-Step ProtectionIEEE Transactions on Power Delivery, 2010
- Out-of-step Detection Using Energy Equilibrium Criterion in Time DomainElectric Power Components and Systems, 2009
- Out-of-step protection fundamentals and advancements2004
- Extended equal area criterion justifications, generalizations, applicationsIEEE Transactions on Power Systems, 1989