Marko Tealane
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marko Tealane has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jako Kilter
Department of Electrical Power Engineering and Mechatronics, Tallinn University of Technology, Tallinn, Estonia
2 shared publications - Marjan Popov
Delft University of Technology, Delft, The Netherlands
2 shared publications - Oleg Bagleybter
Grid Automation, GE Renewable Energy, Edinburgh, U.K.
2 shared publications Birkir Heimisson
Landsnet hf., Reykjavk, Iceland
1 shared publicationDanny Klaar
TenneT TSO B.V., Arnhem, The Netherlands
1 shared publication- Ivar Kiitam
Department of Electrical Power Engineering and Mechatronics, Tallinn University of Technology, 19086 Tallinn, Estonia
1 shared publication
Latest Publications
- Open Access
- 25 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 78290-78305
Out-of-Step Protection Based on Discrete Angle Derivatives
This paper presents an out-of-step protection algorithm based on angle derivatives, which makes use of wide-area measurements and can be applied on arbitrary tie-lines in electrical power systems. The developed algorithm uses PMU measurements that are taken at both ends of a transmission line. Based on the changes of the electrical quantities in the power system, the algorithm detects unstable system conditions. Thus, the developed solution is settingless and can be easily applied where an out-of-step condition is expected. The concept is deployed by using an industrial controller and tested by conducting numerous hardware-in-the-loop simulations. Additionally, recorded data from actual out-of-step events in the Icelandic power system are used to validate the developed algorithm. The performance of the implemented method is compared against the traditional impedance-based out-of-step protection methods. The results confirm that the proposed algorithm detects out-of-step conditions more reliably and faster than the traditional impedance-based solutions.
- 25 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 78290-78305
Open AccessOut-of-Step Protection Based on Discrete Angle Derivatives
This paper presents an out-of-step protection algorithm based on angle derivatives, which makes use of wide-area measurements and can be applied on arbitrary tie-lines in electrical power systems. The developed algorithm uses PMU measurements that are taken at both ends of a transmission line. Based on the changes of the electrical quantities in the power system, the algorithm detects unstable system conditions. Thus, the developed solution is settingless and can be easily applied where an out-of-step condition is expected. The concept is deployed by using an industrial controller and tested by conducting numerous hardware-in-the-loop simulations. Additionally, recorded data from actual out-of-step events in the Icelandic power system are used to validate the developed algorithm. The performance of the implemented method is compared against the traditional impedance-based out-of-step protection methods. The results confirm that the proposed algorithm detects out-of-step conditions more reliably and faster than the traditional impedance-based solutions.
- Open Access
- 4 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 14807-14818
Online Detection of Out-of-Step Condition Using PMU-Determined System Impedances
This paper presents a robust and adaptive out-of-step (OOS) protection algorithm, using wide-area information, that can be applied on tie-lines in observable power systems. The developed algorithm is based upon real-time computation of the system impedance and makes use of the well-known power-angle characteristic. In this way, a setting-less OOS concept in real-time environment is developed, which is applicable for tie-lines in an arbitrary power system. Furthermore, the developed protection algorithm is installed on hardware and is verified by numerous tests. The performance of the new hardware implementation is compared to the traditional impedance-based OOS protection methods. The results confirm that the proposed algorithm detects OOS conditions faster and more reliably than the traditional impedance-based solutions.
- 4 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 14807-14818
Open AccessOnline Detection of Out-of-Step Condition Using PMU-Determined System Impedances
This paper presents a robust and adaptive out-of-step (OOS) protection algorithm, using wide-area information, that can be applied on tie-lines in observable power systems. The developed algorithm is based upon real-time computation of the system impedance and makes use of the well-known power-angle characteristic. In this way, a setting-less OOS concept in real-time environment is developed, which is applicable for tie-lines in an arbitrary power system. Furthermore, the developed protection algorithm is installed on hardware and is verified by numerous tests. The performance of the new hardware implementation is compared to the traditional impedance-based OOS protection methods. The results confirm that the proposed algorithm detects OOS conditions faster and more reliably than the traditional impedance-based solutions.
- 28 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 702-706
Electrical and mechanical properties of service-aged medium voltage porcelain support insulators
The aging of insulation materials is of great importance in determining useful lifetime of electrical equipment. Mechanical and electrical tests were conducted on aged 6 kV porcelain support insulators, which were in service for 70 years in an indoor substation. The mechanical tests included compression, tension and bending of the insulators until failure. The electrical tests included application of standard lightning impulse voltages and determining the 50% probability flashover voltage for both positive and negative polarities and determining 50 Hz AC flashover voltage. In electrical tests, puncture did not occur. Across all of the tests, the insulators were found to conform to the initial parameters specified by the manufacturer. It was found that the deterioration of the porcelain insulator had not reached an excessively high level despite the substantially long service time.
- 28 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 702-706
Electrical and mechanical properties of service-aged medium voltage porcelain support insulators
The aging of insulation materials is of great importance in determining useful lifetime of electrical equipment. Mechanical and electrical tests were conducted on aged 6 kV porcelain support insulators, which were in service for 70 years in an indoor substation. The mechanical tests included compression, tension and bending of the insulators until failure. The electrical tests included application of standard lightning impulse voltages and determining the 50% probability flashover voltage for both positive and negative polarities and determining 50 Hz AC flashover voltage. In electrical tests, puncture did not occur. Across all of the tests, the insulators were found to conform to the initial parameters specified by the manufacturer. It was found that the deterioration of the porcelain insulator had not reached an excessively high level despite the substantially long service time.