Biocompatible reference electrodes to enhance chronic electrochemical signal fidelity in vivo
- 1 October 2021
- journal article
- review article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 413 (27) , 6689-6701
Abstract
In vivo electrochemistry is a vital tool of neuroscience that allows for the detection, identification, and quantification of neurotransmitters, their metabolites, and other important analytes. One important goal of in vivo electrochemistry is a better understanding of progressive neurological disorders (e.g., Parkinson’s disease). A complete understanding of such disorders can only be achieved through a combination of acute (i.e., minutes to hours) and chronic (i.e., days or longer) experimentation. Chronic studies are more challenging because they require prolonged implantation of electrodes, which elicits an immune response, leading to glial encapsulation of the electrodes and altered electrode performance (i.e., biofouling). Biofouling leads to increased electrode impedance and reference electrode polarization, both of which diminish the selectivity and sensitivity of in vivo electrochemical measurements. The increased impedance factor has been successfully mitigated previously with the use of a counter electrode, but the challenge of reference electrode polarization remains. The commonly used Ag/AgCl reference electrode lacks the long-term potential stability in vivo required for chronic measurements. In addition, the cytotoxicity of Ag/AgCl adversely affects animal experimentation and prohibits implantation in humans, hindering translational research progress. Thus, a move toward biocompatible reference electrodes with superior chronic potential stability is necessary. Two qualifying materials, iridium oxide and boron-doped diamond, are introduced and discussed in terms of their electrochemical properties, biocompatibilities, fabrication methods, and applications. In vivo electrochemistry continues to advance toward more chronic experimentation in both animal models and humans, necessitating the utilization of biocompatible reference electrodes that should provide superior potential stability and allow for unprecedented chronic signal fidelity when used with a counter electrode for impedance mitigation.Keywords
Funding Information
- National Institutes of Health (R01 NS112176)
This publication has 130 references indexed in Scilit:
- In vivo pH monitoring using boron doped diamond microelectrode and silver needles: Application to stomach disorder diagnosisScientific Reports, 2013
- In vivo assessment of cancerous tumors using boron doped diamond microelectrodeScientific Reports, 2012
- Multiplexed, High Density Electrophysiology with Nanofabricated Neural ProbesPLOS ONE, 2011
- Chronically Implanted, Nafion-Coated Ag/AgCl Reference Electrodes for Neurochemical ApplicationsACS Chemical Neuroscience, 2011
- Enhanced Growth and Osteogenic Differentiation of Human Osteoblast-Like Cells on Boron-Doped Nanocrystalline Diamond Thin FilmsPLOS ONE, 2011
- Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer coatings facilitate smaller neural recording electrodesJournal of Neural Engineering, 2011
- Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex usingin vivotwo-photon mappingJournal of Neural Engineering, 2010
- Chronic microsensors for longitudinal, subsecond dopamine detection in behaving animalsNature Methods, 2009
- Creating low-impedance tetrodes by electroplating with additivesSensors and Actuators A: Physical, 2009
- In vivoimpedance spectroscopy of deep brain stimulation electrodesJournal of Neural Engineering, 2009