Michael Leandro Heien
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michael Leandro Heien has a total of 125 co-authors. Here are the top co-authors by number of shared publications:
Christopher W. Atcherley
Department of Research, Mayo Clinic, Scottsdale, AZ, Tucson, AZ, USA
8 shared publications- Dong Pyo Jang
Department of Biomedical Engineering, Hanyang University, Seoul, Republic of Korea
7 shared publications Charles D. Blaha
Department of Neurologic Surgery, Mayo Clinic, Rochester, Minnesota 55902, United States
5 shared publicationsKendall H. Lee
Department of Neurologic Surgery, Mayo Clinic, Rochester, MN 55905, USA
5 shared publicationsKevin E. Bennet
Department of Neurologic Surgery, Mayo Clinic, Rochester, MN 55905, USA
5 shared publicationsKate L. Parent
Department of Chemistry and Biochemistry, University of Arizona, Tucson, AZ, USA
4 shared publications
Latest Publications
- Open Access
- 4 August 2026
- Published by MDPI AG in Preprints.org
Calibration and Measurement of Primary Nutrients for Hydroponics Using Ultraviolet-Visible Spectroscopy
This paper outlines a methodology for using Ultraviolet-Visible (UV-Vis) spectroscopy to measure the concentration of the primary nutrients (N, P, K) and calcium (Ca) for managing hydroponics fertigation solutions and is an extension of previous work presented by the team at GreenSys 2025. This project focuses on supplanting electrical conductivity (EC) as the go-to for inline control of the nutrient mixtures. EC only gives a picture of the total nutrient content of the solution and cannot give insight into the amount of each element present. Others have demonstrated UV-Vis spectroscopy in this measurement role using machine learning for the primary nutrients. The aim here was to improve upon that with a calibration method that is quick, easily reproducible, and usable for an inline controller for near real-time control in hydroponics while also adding support for Ca measurement.
- 4 August 2026
- Published by MDPI AG in Preprints.org
Open AccessCalibration and Measurement of Primary Nutrients for Hydroponics Using Ultraviolet-Visible Spectroscopy
This paper outlines a methodology for using Ultraviolet-Visible (UV-Vis) spectroscopy to measure the concentration of the primary nutrients (N, P, K) and calcium (Ca) for managing hydroponics fertigation solutions and is an extension of previous work presented by the team at GreenSys 2025. This project focuses on supplanting electrical conductivity (EC) as the go-to for inline control of the nutrient mixtures. EC only gives a picture of the total nutrient content of the solution and cannot give insight into the amount of each element present. Others have demonstrated UV-Vis spectroscopy in this measurement role using machine learning for the primary nutrients. The aim here was to improve upon that with a calibration method that is quick, easily reproducible, and usable for an inline controller for near real-time control in hydroponics while also adding support for Ca measurement.
- Open Access
- 17 September 2024
- Published by American Chemical Society (ACS) in ACS Medicinal Chemistry Letters
- Vol. 15 (10) , 1731-1740
Cyclic Glycopeptide Analogs of Endomorphin-1 Provide Highly Effective Antinociception in Male and Female Mice
Opioids acting at the mu opioid receptor (MOR) remain the most effective treatment for moderate to severe pain, but their use is limited by serious side effects. We have shown that a cyclized analog of endomorphin-1 provided pain relief comparable to that of morphine with reduction or absence of several side effects, including abuse liability. Glycosylation can promote penetration of cellular barriers. Here we developed cyclic glycopeptide endomorphin (glycoEM) analogs as drug candidates for potent and long-lasting analgesia. The analogs were assessed in receptor binding and functional assays and for blood-brain barrier penetration by microdialysis and MS. Two of the analogs showed MOR selectivity and more potent and longer lasting antinociception than morphine in male and female mice. Comparable antinociception occurred at A2 doses 5-fold lower (20-fold on a molar basis) than morphine doses. The results support further study of the glycoEMs for clinical application.
- 17 September 2024
- Published by American Chemical Society (ACS) in ACS Medicinal Chemistry Letters
- Vol. 15 (10) , 1731-1740
Open AccessCyclic Glycopeptide Analogs of Endomorphin-1 Provide Highly Effective Antinociception in Male and Female Mice
Opioids acting at the mu opioid receptor (MOR) remain the most effective treatment for moderate to severe pain, but their use is limited by serious side effects. We have shown that a cyclized analog of endomorphin-1 provided pain relief comparable to that of morphine with reduction or absence of several side effects, including abuse liability. Glycosylation can promote penetration of cellular barriers. Here we developed cyclic glycopeptide endomorphin (glycoEM) analogs as drug candidates for potent and long-lasting analgesia. The analogs were assessed in receptor binding and functional assays and for blood-brain barrier penetration by microdialysis and MS. Two of the analogs showed MOR selectivity and more potent and longer lasting antinociception than morphine in male and female mice. Comparable antinociception occurred at A2 doses 5-fold lower (20-fold on a molar basis) than morphine doses. The results support further study of the glycoEMs for clinical application.
- 3 July 2024
- Published by American Chemical Society (ACS) in ACS Chemical Neuroscience
- Vol. 15 (14) , 2643-2653
Dopamine Release Dynamics in the Nucleus Accumbens Are Modulated by the Timing of Electrical Stimulation Pulses When Applied to the Medial Forebrain Bundle and Medial Prefrontal Cortex
Electrical brain stimulation has been used in vivo and in vitro to investigate neural circuitry. Historically, stimulation parameters such as amplitude, frequency, and pulse width were varied to investigate their effects on neurotransmitter release and behavior. These experiments have traditionally employed fixed-frequency stimulation patterns, but it has previously been found that neurons are more precisely tuned to variable input. Introducing variability into the interpulse interval of stimulation pulses will inform on how dopaminergic release can be modulated by variability in pulse timing. Here, dopaminergic release in rats is monitored in the nucleus accumbens (NAc), a key dopaminergic center which plays a role in learning and motivation, by fast-scan cyclic voltammetry. Dopaminergic release in the NAc could also be modulated by stimulation region due to differences in connectivity. We targeted two regions for stimulation-the medial forebrain bundle (MFB) and the medial prefrontal cortex (mPFC)-due to their involvement in reward processing and projections to the NAc. Our goal is to investigate how variable interpulse interval stimulation patterns delivered to these regions affect the time course of dopamine release in the NAc. We found that stimulating the MFB with these variable stimulation patterns saw a highly responsive, frequency-driven dopaminergic response. In contrast, variable stimulation patterns applied to the mPFC were not as sensitive to the variable frequency changes. This work will help inform on how stimulation patterns can be tuned specifically to the stimulation region to improve the efficiency of electrical stimulation and control dopamine release.
- 3 July 2024
- Published by American Chemical Society (ACS) in ACS Chemical Neuroscience
- Vol. 15 (14) , 2643-2653
Dopamine Release Dynamics in the Nucleus Accumbens Are Modulated by the Timing of Electrical Stimulation Pulses When Applied to the Medial Forebrain Bundle and Medial Prefrontal Cortex
Electrical brain stimulation has been used in vivo and in vitro to investigate neural circuitry. Historically, stimulation parameters such as amplitude, frequency, and pulse width were varied to investigate their effects on neurotransmitter release and behavior. These experiments have traditionally employed fixed-frequency stimulation patterns, but it has previously been found that neurons are more precisely tuned to variable input. Introducing variability into the interpulse interval of stimulation pulses will inform on how dopaminergic release can be modulated by variability in pulse timing. Here, dopaminergic release in rats is monitored in the nucleus accumbens (NAc), a key dopaminergic center which plays a role in learning and motivation, by fast-scan cyclic voltammetry. Dopaminergic release in the NAc could also be modulated by stimulation region due to differences in connectivity. We targeted two regions for stimulation-the medial forebrain bundle (MFB) and the medial prefrontal cortex (mPFC)-due to their involvement in reward processing and projections to the NAc. Our goal is to investigate how variable interpulse interval stimulation patterns delivered to these regions affect the time course of dopamine release in the NAc. We found that stimulating the MFB with these variable stimulation patterns saw a highly responsive, frequency-driven dopaminergic response. In contrast, variable stimulation patterns applied to the mPFC were not as sensitive to the variable frequency changes. This work will help inform on how stimulation patterns can be tuned specifically to the stimulation region to improve the efficiency of electrical stimulation and control dopamine release.
- Open Access
- 16 June 2024
- Published by Elsevier in Neuropharmacology
- Vol. 257, 110047
Differential effects of opioid receptor antagonism on the anti-dyskinetic and anti-parkinsonian effects of sub-anesthetic ketamine treatment in a preclinical model
- 16 June 2024
- Published by Elsevier in Neuropharmacology
- Vol. 257, 110047
Open AccessDifferential effects of opioid receptor antagonism on the anti-dyskinetic and anti-parkinsonian effects of sub-anesthetic ketamine treatment in a preclinical model
- 4 April 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (10) , 3008-3016
Understanding the different effects of fouling mechanisms on working and reference electrodes in fast-scan cyclic voltammetry for neurotransmitter detection
The distinct impacts of fouling mechanisms on a carbon fiber microelectrode and an Ag/AgCl reference electrode, affecting their performance in neurotransmitter detection via Fast-scan Cyclic Voltammetry.
- 4 April 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (10) , 3008-3016
Understanding the different effects of fouling mechanisms on working and reference electrodes in fast-scan cyclic voltammetry for neurotransmitter detection
The distinct impacts of fouling mechanisms on a carbon fiber microelectrode and an Ag/AgCl reference electrode, affecting their performance in neurotransmitter detection via Fast-scan Cyclic Voltammetry.
- Open Access
- 29 November 2023
- Published by American Chemical Society (ACS) in ACS Chemical Neuroscience
- Vol. 14 (24) , 4264-4273
Techniques for Measurement of Serotonin: Implications in Neuropsychiatric Disorders and Advances in Absolute Value Recording Methods
- 29 November 2023
- Published by American Chemical Society (ACS) in ACS Chemical Neuroscience
- Vol. 14 (24) , 4264-4273
Open AccessTechniques for Measurement of Serotonin: Implications in Neuropsychiatric Disorders and Advances in Absolute Value Recording Methods
- 24 January 2023
- Published by American Chemical Society (ACS) in ACS Medicinal Chemistry Letters
- Vol. 14 (2) , 163-170
Structure-Based Design of Glycosylated Oxytocin Analogues with Improved Selectivity and Antinociceptive Activity
Acute and chronic pain is often treated with opioids despite the negative side effects of constipation, physical dependence, respiratory depression, and overdose. The misuse of opioid analgesics has given rise to the opioid crisis/epidemic, and alternate nonaddictive analgesics are urgently needed. Oxytocin, a pituitary hormone, is an alternative to the small molecule treatments available and has been used as an analgesic as well as for the treatment and prevention of opioid use disorder (OUD). Clinical implementation is limited by its poor pharmacokinetic profile, a result of the labile disulfide bond between two cysteine residues in the native sequence. Stable brain penetrant oxytocin analogues have been synthesized by replacement of the disulfide bond with a stable lactam and glycosidation of the C-terminus. These analogues show exquisite selectivity for the oxytocin receptor and potent in vivo antinociception in mice following peripheral (i.v.) administration, supporting further study of their clinical potential.
- 24 January 2023
- Published by American Chemical Society (ACS) in ACS Medicinal Chemistry Letters
- Vol. 14 (2) , 163-170
Structure-Based Design of Glycosylated Oxytocin Analogues with Improved Selectivity and Antinociceptive Activity
Acute and chronic pain is often treated with opioids despite the negative side effects of constipation, physical dependence, respiratory depression, and overdose. The misuse of opioid analgesics has given rise to the opioid crisis/epidemic, and alternate nonaddictive analgesics are urgently needed. Oxytocin, a pituitary hormone, is an alternative to the small molecule treatments available and has been used as an analgesic as well as for the treatment and prevention of opioid use disorder (OUD). Clinical implementation is limited by its poor pharmacokinetic profile, a result of the labile disulfide bond between two cysteine residues in the native sequence. Stable brain penetrant oxytocin analogues have been synthesized by replacement of the disulfide bond with a stable lactam and glycosidation of the C-terminus. These analogues show exquisite selectivity for the oxytocin receptor and potent in vivo antinociception in mice following peripheral (i.v.) administration, supporting further study of their clinical potential.
- 25 July 2022
- Published by American Chemical Society (ACS) in ACS Chemical Neuroscience
- Vol. 13 (15) , 2288-2297
Neurochemical Concentration Prediction Using Deep Learning vs Principal Component Regression in Fast Scan Cyclic Voltammetry: A Comparison Study
Neurotransmitters, such as dopamine and serotonin, are responsible for mediating a wide array of neurologic functions, from memory to motivation. From measurements using fast scan cyclic voltammetry (FSCV), one of the main tools used to detect synaptic efflux of neurochemicals in vivo, principal component regression (PCR), has been commonly used to predict the identity and concentrations of neurotransmitters. However, the sensitivity and discrimination performance of PCR have room for improvement, especially for analyzing mixtures of similar oxidizable neurochemicals. Deep learning may be able to address these challenges. To date, there have been a few studies to apply machine learning to FSCV, but no attempt to apply deep learning to neurotransmitter mixture discrimination and no comparative study have been performed between PCR and deep learning methods to demonstrate which is more accurate for FSCV analysis so far. In this study, we compared the neurochemical identification and concentration estimation performance of PCR and deep learning in an analysis of FSCV recordings of catecholamine and indolamine neurotransmitters. Both analysis methods were tested on in vitro FSCV data with a single or mixture of neurotransmitters at the desired concentration. In addition, the estimation performance of PCR and deep learning was compared in incorporation with in vivo experiments to evaluate the practical usage. Pharmacological tests were also conducted to see whether deep learning would track the increased amount of catecholamine levels in the brain. Using conventional FSCV, we used five electrodes and recorded in vitro background-subtracted cyclic voltammograms from four neurotransmitters, dopamine, epinephrine, norepinephrine, and serotonin, with five concentrations of each substance, as well as various mixtures of the four analytes. The results showed that the identification accuracy errors were reduced 5-20% by using deep learning compared to using PCR for mixture analysis, and the two methods were comparable for single analyte analysis. The applied deep-learning-based method demonstrated not only higher identification accuracy but also better discrimination performance than PCR for mixtures of neurochemicals and even for in vivo testing. Therefore, we suggest that deep learning should be chosen as a more reliable tool to analyze FSCV data compared to conventional PCR methods although further work is still needed on developing complete validation procedures prior to widespread use.
- 25 July 2022
- Published by American Chemical Society (ACS) in ACS Chemical Neuroscience
- Vol. 13 (15) , 2288-2297
Neurochemical Concentration Prediction Using Deep Learning vs Principal Component Regression in Fast Scan Cyclic Voltammetry: A Comparison Study
Neurotransmitters, such as dopamine and serotonin, are responsible for mediating a wide array of neurologic functions, from memory to motivation. From measurements using fast scan cyclic voltammetry (FSCV), one of the main tools used to detect synaptic efflux of neurochemicals in vivo, principal component regression (PCR), has been commonly used to predict the identity and concentrations of neurotransmitters. However, the sensitivity and discrimination performance of PCR have room for improvement, especially for analyzing mixtures of similar oxidizable neurochemicals. Deep learning may be able to address these challenges. To date, there have been a few studies to apply machine learning to FSCV, but no attempt to apply deep learning to neurotransmitter mixture discrimination and no comparative study have been performed between PCR and deep learning methods to demonstrate which is more accurate for FSCV analysis so far. In this study, we compared the neurochemical identification and concentration estimation performance of PCR and deep learning in an analysis of FSCV recordings of catecholamine and indolamine neurotransmitters. Both analysis methods were tested on in vitro FSCV data with a single or mixture of neurotransmitters at the desired concentration. In addition, the estimation performance of PCR and deep learning was compared in incorporation with in vivo experiments to evaluate the practical usage. Pharmacological tests were also conducted to see whether deep learning would track the increased amount of catecholamine levels in the brain. Using conventional FSCV, we used five electrodes and recorded in vitro background-subtracted cyclic voltammograms from four neurotransmitters, dopamine, epinephrine, norepinephrine, and serotonin, with five concentrations of each substance, as well as various mixtures of the four analytes. The results showed that the identification accuracy errors were reduced 5-20% by using deep learning compared to using PCR for mixture analysis, and the two methods were comparable for single analyte analysis. The applied deep-learning-based method demonstrated not only higher identification accuracy but also better discrimination performance than PCR for mixtures of neurochemicals and even for in vivo testing. Therefore, we suggest that deep learning should be chosen as a more reliable tool to analyze FSCV data compared to conventional PCR methods although further work is still needed on developing complete validation procedures prior to widespread use.
- 2 December 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (51) , 16987-16994
Tonic Serotonin MeasurementsIn VivoUsing N-Shaped Multiple Cyclic Square Wave Voltammetry
Here, we present the development of a novel voltammetric technique, N-shaped multiple cyclic square wave voltammetry (N-MCSWV) and its application in vivo. It allows quantitative measurements of tonic extracellular levels of serotonin in vivo with mitigated fouling effects. N-MCSWV enriches the electrochemical information by generating high dimensional voltammograms, which enables high sensitivity and selectivity against 5-hydroindoleacetic acid (5-HIAA), dopamine, 3,4-dihydroxyphenylacetic acid (DOPAC), histamine, ascorbic acid, norepinephrine, adenosine, and pH. Using N-MCSWV, in combination with PEDOT:Nafion-coated carbon fiber microelectrodes, a tonic serotonin concentration of 52 ± 5.8 nM (n = 20 rats, ±SEM) was determined in the substantia nigra pars reticulata of urethane-anesthetized rats. Pharmacological challenges with dopaminergic, noradrenergic, and serotonergic synaptic reuptake inhibitors supported the ability of N-MCSWV to selectively detect tonic serotonin levels in vivo. Overall, N-MCSWV is a novel voltammetric technique for analytical quantification of serotonin. It offers continuous monitoring of changes in tonic serotonin concentrations in the brain to further our understanding of the role of serotonin in normal behaviors and psychiatric disorders.
- 2 December 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (51) , 16987-16994
Tonic Serotonin MeasurementsIn VivoUsing N-Shaped Multiple Cyclic Square Wave Voltammetry
Here, we present the development of a novel voltammetric technique, N-shaped multiple cyclic square wave voltammetry (N-MCSWV) and its application in vivo. It allows quantitative measurements of tonic extracellular levels of serotonin in vivo with mitigated fouling effects. N-MCSWV enriches the electrochemical information by generating high dimensional voltammograms, which enables high sensitivity and selectivity against 5-hydroindoleacetic acid (5-HIAA), dopamine, 3,4-dihydroxyphenylacetic acid (DOPAC), histamine, ascorbic acid, norepinephrine, adenosine, and pH. Using N-MCSWV, in combination with PEDOT:Nafion-coated carbon fiber microelectrodes, a tonic serotonin concentration of 52 ± 5.8 nM (n = 20 rats, ±SEM) was determined in the substantia nigra pars reticulata of urethane-anesthetized rats. Pharmacological challenges with dopaminergic, noradrenergic, and serotonergic synaptic reuptake inhibitors supported the ability of N-MCSWV to selectively detect tonic serotonin levels in vivo. Overall, N-MCSWV is a novel voltammetric technique for analytical quantification of serotonin. It offers continuous monitoring of changes in tonic serotonin concentrations in the brain to further our understanding of the role of serotonin in normal behaviors and psychiatric disorders.
- 1 October 2021
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 413 (27) , 6689-6701
Biocompatible reference electrodes to enhance chronic electrochemical signal fidelity in vivo
In vivo electrochemistry is a vital tool of neuroscience that allows for the detection, identification, and quantification of neurotransmitters, their metabolites, and other important analytes. One important goal of in vivo electrochemistry is a better understanding of progressive neurological disorders (e.g., Parkinson’s disease). A complete understanding of such disorders can only be achieved through a combination of acute (i.e., minutes to hours) and chronic (i.e., days or longer) experimentation. Chronic studies are more challenging because they require prolonged implantation of electrodes, which elicits an immune response, leading to glial encapsulation of the electrodes and altered electrode performance (i.e., biofouling). Biofouling leads to increased electrode impedance and reference electrode polarization, both of which diminish the selectivity and sensitivity of in vivo electrochemical measurements. The increased impedance factor has been successfully mitigated previously with the use of a counter electrode, but the challenge of reference electrode polarization remains. The commonly used Ag/AgCl reference electrode lacks the long-term potential stability in vivo required for chronic measurements. In addition, the cytotoxicity of Ag/AgCl adversely affects animal experimentation and prohibits implantation in humans, hindering translational research progress. Thus, a move toward biocompatible reference electrodes with superior chronic potential stability is necessary. Two qualifying materials, iridium oxide and boron-doped diamond, are introduced and discussed in terms of their electrochemical properties, biocompatibilities, fabrication methods, and applications. In vivo electrochemistry continues to advance toward more chronic experimentation in both animal models and humans, necessitating the utilization of biocompatible reference electrodes that should provide superior potential stability and allow for unprecedented chronic signal fidelity when used with a counter electrode for impedance mitigation.
- 1 October 2021
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 413 (27) , 6689-6701
Biocompatible reference electrodes to enhance chronic electrochemical signal fidelity in vivo
In vivo electrochemistry is a vital tool of neuroscience that allows for the detection, identification, and quantification of neurotransmitters, their metabolites, and other important analytes. One important goal of in vivo electrochemistry is a better understanding of progressive neurological disorders (e.g., Parkinson’s disease). A complete understanding of such disorders can only be achieved through a combination of acute (i.e., minutes to hours) and chronic (i.e., days or longer) experimentation. Chronic studies are more challenging because they require prolonged implantation of electrodes, which elicits an immune response, leading to glial encapsulation of the electrodes and altered electrode performance (i.e., biofouling). Biofouling leads to increased electrode impedance and reference electrode polarization, both of which diminish the selectivity and sensitivity of in vivo electrochemical measurements. The increased impedance factor has been successfully mitigated previously with the use of a counter electrode, but the challenge of reference electrode polarization remains. The commonly used Ag/AgCl reference electrode lacks the long-term potential stability in vivo required for chronic measurements. In addition, the cytotoxicity of Ag/AgCl adversely affects animal experimentation and prohibits implantation in humans, hindering translational research progress. Thus, a move toward biocompatible reference electrodes with superior chronic potential stability is necessary. Two qualifying materials, iridium oxide and boron-doped diamond, are introduced and discussed in terms of their electrochemical properties, biocompatibilities, fabrication methods, and applications. In vivo electrochemistry continues to advance toward more chronic experimentation in both animal models and humans, necessitating the utilization of biocompatible reference electrodes that should provide superior potential stability and allow for unprecedented chronic signal fidelity when used with a counter electrode for impedance mitigation.