Improving the arterial input function in dynamic contrast enhanced MRI by fitting the signal in the complex plane
- 3 November 2015
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 76 (4) , 1236-1245
Abstract
Purpose: Dynamic contrast enhanced (DCE) imaging is a widely used technique in oncologic imaging. An essential prerequisite for obtaining quantitative values from DCE‐MRI is the determination of the arterial input function (AIF). However, it is very challenging to accurately estimate the AIF using MR. A comprehensive model, which uses complex data instead of either magnitude or phase, was developed to improve AIF estimation.Theory and Methods: The model was first applied to simulated data. Subsequently, the accuracy of the estimated contrast agent concentration was validated in a phantom. Finally the method was applied to existing DCE scans of 13 prostate cancer patients.Results: The complex signal method combines the complementary strengths of the magnitude and phase method, increasing the precision and accuracy of concentration estimation in simulated and phantom data. The in vivo AIFs show a good agreement between arterial voxels (standard deviation in the peak and tail equal 0.4 mM and 0.12 mM, respectively). Furthermore, the dynamic behavior closely followed the AIF obtained with DCE‐CT in the same patients (mean correlation coefficient: 0.92).Conclusion: By using the complex signal, the AIF estimation becomes more accurate and precise. This might enable patient specific AIFs, thereby improving the quantitative values obtained from DCE‐MRI. Magn Reson Med 76:1236–1245, 2016.Keywords
This publication has 31 references indexed in Scilit:
- A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: II.In vivoresultsPhysics in Medicine & Biology, 2010
- Reproducibility of Perfusion Parameters in Dynamic Contrast-Enhanced MRI of Lung and Liver Tumors: Effect on Estimates of Patient Sample Size in Clinical Trials and on Individual Patient ResponsesAmerican Journal of Roentgenology, 2010
- Use of cardiac output to improve measurement of input function in quantitative dynamic contrast‐enhanced MRIJournal of Magnetic Resonance Imaging, 2009
- Uncertainty and bias in contrast concentration measurements using spoiled gradient echo pulse sequencesPhysics in Medicine & Biology, 2008
- T1 measurement of flowing blood and arterial input function determination for quantitative 3D T1‐weighted DCE‐MRIJournal of Magnetic Resonance Imaging, 2007
- Experimentally‐derived functional form for a population‐averaged high‐temporal‐resolution arterial input function for dynamic contrast‐enhanced MRIMagnetic Resonance in Medicine, 2006
- Rapid high‐resolution T1 mapping by variable flip angles: Accurate and precise measurements in the presence of radiofrequency field inhomogeneityMagnetic Resonance in Medicine, 2006
- T1, T2 relaxation and magnetization transfer in tissue at 3TMagnetic Resonance in Medicine, 2005
- Dynamic contrast‐enhanced MRI in clinical oncology: Current status and future directionsJournal of Magnetic Resonance Imaging, 2002
- Arterial input functions from MR phase imagingMagnetic Resonance in Medicine, 1996