Ellis Beld
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ellis Beld has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Jan J W Lagendijk
Department of Radiotherapy, University Medical Center Utrecht, Utrecht, Utrecht, NETHERLANDS
3 shared publicationsPeter R Seevinck
Image Sciences Institute, University Medical Center Utrecht, P.O. Box 85500, 3508 GA, Room Q0S.459 , Utrecht , The Netherlands, Utrecht, NETHERLANDS
3 shared publicationsJ J W Lagendijk
Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
2 shared publicationsJ.J.W. Lagendijk
Univ Med Ctr Utrecht, Dept Radiotherapy, Utrecht, Netherlands
2 shared publicationsJan J.W. Lagendijk
Department of Radiotherapy, University Medical Center Utrecht, Utrecht, the Netherlands
2 shared publicationsJochem R N van der Voort van Zyp
University Medical Center Utrecht, Utrecht, Utrecht, NETHERLANDS
2 shared publications
Latest Publications
- Open Access
- 25 July 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (18) , 185001
Visualization of gold fiducial markers in the prostate using phase-cycled bSSFP imaging for MRI-only radiotherapy
In this work, we present a new method for visualization of fiducial markers (FMs) in the prostate for MRI-only radiotherapy with a positive contrast directly at the MR console. The method is based on high bandwidth phase-cycled balanced steady-state free precession (bSSFP) sequence, which is available on many clinical scanners, does not require any additional post-processing or software, and has a higher signal-to-noise (SNR) compared to conventional gradient-echo (GE) imaging. Complex phase-cycled bSSFP data is acquired with different RF phase increment settings such that the manifestation of the artifacts around FMs in the acquired complex images is different for each dynamic acquisition and depends on the RF phase increment used. First, we performed numerical simulations to investigate the complex-valued phase-cycled bSSFP signal in the presence of a gold FM, and to investigate the relation of the true physical location of the FM with the geometrical manifestation of the artifacts. Next, to validate the simulations, we performed phantoms and in vivo studies and compared the experimentally obtained artifacts with those predicted in simulations. The accuracy of the method was assessed by comparing the distances between the FM’s centers and the center of mass of FMs system measured using phase-cycled bSSFP MR images and using reference CT (or MRI-only) images. The results show accurate (within 1 mm) matching of FMs localization between CT and MR images on five patients, proving the feasibility of in vivo FMs detection on MR images only. The FMs show a positive contrast with respect to the prostate background on real/imaginary phase-cycled bSSFP images, which was confirmed by simulations. The proposed method facilitates robust FMs visualization with positive contrast directly at the MR console, allowing RT technicians to obtain immediate feedback on the anticipated feasibility of accurate FMs localization while the patient is being scanned.
- 25 July 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (18) , 185001
Open AccessVisualization of gold fiducial markers in the prostate using phase-cycled bSSFP imaging for MRI-only radiotherapy
In this work, we present a new method for visualization of fiducial markers (FMs) in the prostate for MRI-only radiotherapy with a positive contrast directly at the MR console. The method is based on high bandwidth phase-cycled balanced steady-state free precession (bSSFP) sequence, which is available on many clinical scanners, does not require any additional post-processing or software, and has a higher signal-to-noise (SNR) compared to conventional gradient-echo (GE) imaging. Complex phase-cycled bSSFP data is acquired with different RF phase increment settings such that the manifestation of the artifacts around FMs in the acquired complex images is different for each dynamic acquisition and depends on the RF phase increment used. First, we performed numerical simulations to investigate the complex-valued phase-cycled bSSFP signal in the presence of a gold FM, and to investigate the relation of the true physical location of the FM with the geometrical manifestation of the artifacts. Next, to validate the simulations, we performed phantoms and in vivo studies and compared the experimentally obtained artifacts with those predicted in simulations. The accuracy of the method was assessed by comparing the distances between the FM’s centers and the center of mass of FMs system measured using phase-cycled bSSFP MR images and using reference CT (or MRI-only) images. The results show accurate (within 1 mm) matching of FMs localization between CT and MR images on five patients, proving the feasibility of in vivo FMs detection on MR images only. The FMs show a positive contrast with respect to the prostate background on real/imaginary phase-cycled bSSFP images, which was confirmed by simulations. The proposed method facilitates robust FMs visualization with positive contrast directly at the MR console, allowing RT technicians to obtain immediate feedback on the anticipated feasibility of accurate FMs localization while the patient is being scanned.
- 26 April 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (9) , 095006
MRI artifact simulation for clinically relevant MRI sequences for guidance of prostate HDR brachytherapy
For the purpose of magnetic resonance imaging (MRI) guidance of prostate high-dose-rate (HDR) brachytherapy, this paper presents a study on the potential of clinically relevant MRI sequences to facilitate tracking or localization of brachytherapy devices (HDR source/titanium needle), and which could simultaneously be used to visualize the anatomy. The tracking or localization involves simulation of the MRI artifact in combination with a template matching algorithm. Simulations of the MRI artifacts induced by an HDR brachytherapy source and a titanium needle were implemented for four types of sequences: spoiled gradient echo, spin echo, balanced steady-state free precession (bSSFP) and bSSFP with spectral attenuated inversion recovery (SPAIR) fat suppression. A phantom study was conducted in which mentioned sequences (in 2D) as well as the volumetric MRI sequences of the current clinical scan protocol were applied to obtain the induced MRI artifacts for an HDR source and a titanium needle. Localization of the objects was performed by a phase correlation based template matching algorithm. The simulated images demonstrated high correspondences with the acquired MR images, and allowed localization of the objects. A comparison between the object positions obtained for all applied MRI sequences showed deviations (from the average position) of 0.2–0.3 mm, proving that all MRI sequences were suitable for localization of the objects, irrespective of their 2D or volumetric nature. This study demonstrated that the MRI artifact induced by an HDR source or a titanium needle could be simulated for the four investigated types of MRI sequences (spoiled gradient echo, spin echo, bSSFP and bSSFP-SPAIR), valuable for real-time object localization in clinical practice. This leads to more flexibility in the choice of MRI sequences for guidance of HDR brachytherapy, as they are suitable for both object localization and anatomy visualization.
- 26 April 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (9) , 095006
MRI artifact simulation for clinically relevant MRI sequences for guidance of prostate HDR brachytherapy
For the purpose of magnetic resonance imaging (MRI) guidance of prostate high-dose-rate (HDR) brachytherapy, this paper presents a study on the potential of clinically relevant MRI sequences to facilitate tracking or localization of brachytherapy devices (HDR source/titanium needle), and which could simultaneously be used to visualize the anatomy. The tracking or localization involves simulation of the MRI artifact in combination with a template matching algorithm. Simulations of the MRI artifacts induced by an HDR brachytherapy source and a titanium needle were implemented for four types of sequences: spoiled gradient echo, spin echo, balanced steady-state free precession (bSSFP) and bSSFP with spectral attenuated inversion recovery (SPAIR) fat suppression. A phantom study was conducted in which mentioned sequences (in 2D) as well as the volumetric MRI sequences of the current clinical scan protocol were applied to obtain the induced MRI artifacts for an HDR source and a titanium needle. Localization of the objects was performed by a phase correlation based template matching algorithm. The simulated images demonstrated high correspondences with the acquired MR images, and allowed localization of the objects. A comparison between the object positions obtained for all applied MRI sequences showed deviations (from the average position) of 0.2–0.3 mm, proving that all MRI sequences were suitable for localization of the objects, irrespective of their 2D or volumetric nature. This study demonstrated that the MRI artifact induced by an HDR source or a titanium needle could be simulated for the four investigated types of MRI sequences (spoiled gradient echo, spin echo, bSSFP and bSSFP-SPAIR), valuable for real-time object localization in clinical practice. This leads to more flexibility in the choice of MRI sequences for guidance of HDR brachytherapy, as they are suitable for both object localization and anatomy visualization.
- 1 November 2018
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 102 (4) , 960-968
Development and Testing of a Magnetic Resonance (MR) Conditional Afterloader for Source Tracking in Magnetic Resonance Imaging-Guided High-Dose-Rate (HDR) Brachytherapy
- 1 November 2018
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 102 (4) , 960-968
Development and Testing of a Magnetic Resonance (MR) Conditional Afterloader for Source Tracking in Magnetic Resonance Imaging-Guided High-Dose-Rate (HDR) Brachytherapy
- Open Access
- 1 April 2018
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 127, S87-S88
OC-0169: Accuracy and precision of high frame rate MR-based HDR brachytherapy source localization
- 1 April 2018
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 127, S87-S88
Open AccessOC-0169: Accuracy and precision of high frame rate MR-based HDR brachytherapy source localization
- 1 April 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (8) , 085002
MR-based source localization for MR-guided HDR brachytherapy
For the purpose of MR-guided high-dose-rate (HDR) brachytherapy, a method for real-time localization of an HDR brachytherapy source was developed, which requires high spatial and temporal resolutions. MR-based localization of an HDR source serves two main aims. First, it enables real-time treatment verification by determination of the HDR source positions during treatment. Second, when using a dummy source, MR-based source localization provides an automatic detection of the source dwell positions after catheter insertion, allowing elimination of the catheter reconstruction procedure. Localization of the HDR source was conducted by simulation of the MR artifacts, followed by a phase correlation localization algorithm applied to the MR images and the simulated images, to determine the position of the HDR source in the MR images. To increase the temporal resolution of the MR acquisition, the spatial resolution was decreased, and a subpixel localization operation was introduced. Furthermore, parallel imaging (sensitivity encoding) was applied to further decrease the MR scan time. The localization method was validated by a comparison with CT, and the accuracy and precision were investigated. The results demonstrated that the described method could be used to determine the HDR source position with a high accuracy (0.4–0.6 mm) and a high precision (⩽0.1 mm), at high temporal resolutions (0.15–1.2 s per slice). This would enable real-time treatment verification as well as an automatic detection of the source dwell positions.
- 1 April 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (8) , 085002
MR-based source localization for MR-guided HDR brachytherapy
For the purpose of MR-guided high-dose-rate (HDR) brachytherapy, a method for real-time localization of an HDR brachytherapy source was developed, which requires high spatial and temporal resolutions. MR-based localization of an HDR source serves two main aims. First, it enables real-time treatment verification by determination of the HDR source positions during treatment. Second, when using a dummy source, MR-based source localization provides an automatic detection of the source dwell positions after catheter insertion, allowing elimination of the catheter reconstruction procedure. Localization of the HDR source was conducted by simulation of the MR artifacts, followed by a phase correlation localization algorithm applied to the MR images and the simulated images, to determine the position of the HDR source in the MR images. To increase the temporal resolution of the MR acquisition, the spatial resolution was decreased, and a subpixel localization operation was introduced. Furthermore, parallel imaging (sensitivity encoding) was applied to further decrease the MR scan time. The localization method was validated by a comparison with CT, and the accuracy and precision were investigated. The results demonstrated that the described method could be used to determine the HDR source position with a high accuracy (0.4–0.6 mm) and a high precision (⩽0.1 mm), at high temporal resolutions (0.15–1.2 s per slice). This would enable real-time treatment verification as well as an automatic detection of the source dwell positions.
- Open Access
- 1 May 2017
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 123, S141-S142
OC-0275: Testing an MR-compatible afterloader for MR-based source tracking in MRI guided HDR brachytherapy
- 1 May 2017
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 123, S141-S142
Open AccessOC-0275: Testing an MR-compatible afterloader for MR-based source tracking in MRI guided HDR brachytherapy
- 31 August 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (18) , 6791-6807
Monte Carlo study of the impact of a magnetic field on the dose distribution in MRI-guided HDR brachytherapy using Ir-192
In the process of developing a robotic MRI-guided high-dose-rate (HDR) prostate brachytherapy treatment, the influence of the MRI scanner's magnetic field on the dose distribution needs to be investigated. A magnetic field causes a deflection of electrons in the plane perpendicular to the magnetic field, and it leads to less lateral scattering along the direction parallel with the magnetic field. Monte Carlo simulations were carried out to determine the influence of the magnetic field on the electron behavior and on the total dose distribution around an Ir-192 source. Furthermore, the influence of air pockets being present near the source was studied. The Monte Carlo package Geant4 was utilized for the simulations. The simulated geometries consisted of a simplified point source inside a water phantom. Magnetic field strengths of 0 T, 1.5 T, 3 T, and 7 T were considered. The simulation results demonstrated that the dose distribution was nearly unaffected by the magnetic field for all investigated magnetic field strengths. Evidence was found that, from a dose perspective, the HDR prostate brachytherapy treatment using Ir-192 can be performed safely inside the MRI scanner. No need was found to account for the magnetic field during treatment planning. Nevertheless, the presence of air pockets in close vicinity to the source, particularly along the direction parallel with the magnetic field, appeared to be an important point for consideration.
- 31 August 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (18) , 6791-6807
Monte Carlo study of the impact of a magnetic field on the dose distribution in MRI-guided HDR brachytherapy using Ir-192
In the process of developing a robotic MRI-guided high-dose-rate (HDR) prostate brachytherapy treatment, the influence of the MRI scanner's magnetic field on the dose distribution needs to be investigated. A magnetic field causes a deflection of electrons in the plane perpendicular to the magnetic field, and it leads to less lateral scattering along the direction parallel with the magnetic field. Monte Carlo simulations were carried out to determine the influence of the magnetic field on the electron behavior and on the total dose distribution around an Ir-192 source. Furthermore, the influence of air pockets being present near the source was studied. The Monte Carlo package Geant4 was utilized for the simulations. The simulated geometries consisted of a simplified point source inside a water phantom. Magnetic field strengths of 0 T, 1.5 T, 3 T, and 7 T were considered. The simulation results demonstrated that the dose distribution was nearly unaffected by the magnetic field for all investigated magnetic field strengths. Evidence was found that, from a dose perspective, the HDR prostate brachytherapy treatment using Ir-192 can be performed safely inside the MRI scanner. No need was found to account for the magnetic field during treatment planning. Nevertheless, the presence of air pockets in close vicinity to the source, particularly along the direction parallel with the magnetic field, appeared to be an important point for consideration.
- 13 January 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (3) , N50-N59
Minimizing the magnetic field effect in MR-linac specific QA-tests: the use of electron dense materials
To address the quality assurance (QA) of a MR-linac which is an MRI combined with a linear accelerator (linac), the traditional linac QA-tests need to be redesigned, since the presence of the static magnetic field in the MR-linac alters the electron trajectory. The latter causes the asymmetry in the dose kernel which is introduced by the magnetic field and hinders accurate geometrical QA-tests for the MR-linac. We introduced the use of electron dense materials (e.g. copper) to reduce the size of the dose kernel and thereby the magnetic field effect on the dose deposition. Two examples of QA-tests are presented in which the geometrical accuracy of the MR-linac was addressed; beam profile and star-shot measurements. The introduced setup was compared with a reference setup and both were tested on a conventional and the MR-linac. The results showed that the symmetry of the recorded beam profile was restored in presence of the copper material and that the isocenter size of the MR-linac can be determined accurately with the introduced star-shot setup. The use of electron dense materials is not limited to the presented QA-tests but has a broad application for beam-specific QA-tests in presence of a magnetic field.
- 13 January 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (3) , N50-N59
Minimizing the magnetic field effect in MR-linac specific QA-tests: the use of electron dense materials
To address the quality assurance (QA) of a MR-linac which is an MRI combined with a linear accelerator (linac), the traditional linac QA-tests need to be redesigned, since the presence of the static magnetic field in the MR-linac alters the electron trajectory. The latter causes the asymmetry in the dose kernel which is introduced by the magnetic field and hinders accurate geometrical QA-tests for the MR-linac. We introduced the use of electron dense materials (e.g. copper) to reduce the size of the dose kernel and thereby the magnetic field effect on the dose deposition. Two examples of QA-tests are presented in which the geometrical accuracy of the MR-linac was addressed; beam profile and star-shot measurements. The introduced setup was compared with a reference setup and both were tested on a conventional and the MR-linac. The results showed that the symmetry of the recorded beam profile was restored in presence of the copper material and that the isocenter size of the MR-linac can be determined accurately with the introduced star-shot setup. The use of electron dense materials is not limited to the presented QA-tests but has a broad application for beam-specific QA-tests in presence of a magnetic field.
- 3 November 2015
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 76 (4) , 1236-1245
Improving the arterial input function in dynamic contrast enhanced MRI by fitting the signal in the complex plane
Purpose: Dynamic contrast enhanced (DCE) imaging is a widely used technique in oncologic imaging. An essential prerequisite for obtaining quantitative values from DCE‐MRI is the determination of the arterial input function (AIF). However, it is very challenging to accurately estimate the AIF using MR. A comprehensive model, which uses complex data instead of either magnitude or phase, was developed to improve AIF estimation.Theory and Methods: The model was first applied to simulated data. Subsequently, the accuracy of the estimated contrast agent concentration was validated in a phantom. Finally the method was applied to existing DCE scans of 13 prostate cancer patients.Results: The complex signal method combines the complementary strengths of the magnitude and phase method, increasing the precision and accuracy of concentration estimation in simulated and phantom data. The in vivo AIFs show a good agreement between arterial voxels (standard deviation in the peak and tail equal 0.4 mM and 0.12 mM, respectively). Furthermore, the dynamic behavior closely followed the AIF obtained with DCE‐CT in the same patients (mean correlation coefficient: 0.92).Conclusion: By using the complex signal, the AIF estimation becomes more accurate and precise. This might enable patient specific AIFs, thereby improving the quantitative values obtained from DCE‐MRI. Magn Reson Med 76:1236–1245, 2016.
- 3 November 2015
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 76 (4) , 1236-1245
Improving the arterial input function in dynamic contrast enhanced MRI by fitting the signal in the complex plane
Purpose: Dynamic contrast enhanced (DCE) imaging is a widely used technique in oncologic imaging. An essential prerequisite for obtaining quantitative values from DCE‐MRI is the determination of the arterial input function (AIF). However, it is very challenging to accurately estimate the AIF using MR. A comprehensive model, which uses complex data instead of either magnitude or phase, was developed to improve AIF estimation.Theory and Methods: The model was first applied to simulated data. Subsequently, the accuracy of the estimated contrast agent concentration was validated in a phantom. Finally the method was applied to existing DCE scans of 13 prostate cancer patients.Results: The complex signal method combines the complementary strengths of the magnitude and phase method, increasing the precision and accuracy of concentration estimation in simulated and phantom data. The in vivo AIFs show a good agreement between arterial voxels (standard deviation in the peak and tail equal 0.4 mM and 0.12 mM, respectively). Furthermore, the dynamic behavior closely followed the AIF obtained with DCE‐CT in the same patients (mean correlation coefficient: 0.92).Conclusion: By using the complex signal, the AIF estimation becomes more accurate and precise. This might enable patient specific AIFs, thereby improving the quantitative values obtained from DCE‐MRI. Magn Reson Med 76:1236–1245, 2016.