Distal Radius Fractures and the Volar Lunate Facet Fragment: Kirschner Wire Fixation in Addition to Volar-Locked Plating
- 24 December 2013
- journal article
- research article
- Published by SAGE Publications in HAND
- Vol. 9 (2) , 230-236
Abstract
Background: The volar lunate facet fragment of a distal radius fracture may not be stabilized with volar-locked plating alone due to the small size and distal location of the fragment. Identification and stabilization of this small fragment is critical as unstable fixation may result in radiocarpal and radioulnar joint subluxation. The addition of spring wire fixation with volar plating can provide stable internal fixation of this critical fracture fragment. Methods: A retrospective review (2006–2011) identified nine patients with distal radius fractures with an associated volar lunate facet fragment that were treated with volar-locked plating and spring wire fixation of the volar lunate facet fragment. Radiographic indices, range of motion, grip strength, and postoperative Patient-related wrist evaluation (PRWE) scores were obtained to assess pain and function. Results: All distal radius fractures healed, and the volar lunate facet fragment reduction was maintained. The mean follow-up was 54 weeks. Mean active range of motion was 46° wrist flexion, 51° wrist extension, 80° pronation, and 68° supination. The mean grip strength was 21 Kg, achieving 66 % of the uninjured limb. The average PRWE score was 17. No patient required removal of hardware or had evidence of tendon irritation. Conclusions: The addition of spring wire fixation to volar-locked plating provided stable fixation of the volar lunate facet fragment of distal radius fractures without complication. This technique addresses a limitation of volar-locked plating to control the small volar lunate facet fragment in distal radius fractures otherwise amenable to volar plating. Level of Evidence: A retrospective case series, Level IV.Keywords
This publication has 23 references indexed in Scilit:
- Complications of Low-Profile Dorsal Versus Volar Locking Plates in the Distal Radius: A Comparative StudyThe Journal of Hand Surgery, 2011
- EARLY EXPERIENCE WITH THE TRIMED FRAGMENT-SPECIFIC FRACTURE FIXATION SYSTEM IN INTRAARTICULAR DISTAL RADIUS FRACTURESJournal of Hand Surgery (European Volume), 2008
- Trimed Fixation System for Displaced Fractures of the Distal RadiusJournal of Trauma: Injury, Infection & Critical Care, 2007
- Functional Outcome and Complications After Volar Plating for Dorsally Displaced, Unstable Fractures of the Distal RadiusThe Journal of Hand Surgery, 2006
- Biomechanics and Biology of Plate Fixation of Distal Radius FracturesHand Clinics, 2005
- Volar Plate Fixation of Distal Radius FracturesHand Clinics, 2005
- Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixationThe Journal of Hand Surgery, 2005
- Beware of the Ulno-Palmar Distal Radial FragmentJournal of Hand Surgery (European Volume), 2002
- Comminuted Intra-articular Fracture of the Distal Radius with Rotation of the Palmar Medial Articular Fragment: Case Reports1992
- The palmar radiocarpal ligaments: A study of adult and fetal human wrist jointsThe Journal of Hand Surgery, 1990