DDDavid G. Dennison

David G. Dennison

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David G. Dennison has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Early Versus Late Motion Following Volar Plating of Distal Radius Fractures

    by David G. Dennison, Charlene L. Blanchard, Bassem Elhassan, Steven L. Moran, Alexander Y. Shin

    Background: Distal radius fractures are common, and the trend in fixation has included the use of locked volar plating. The duration of splinting required after surgery and the effect splinting has upon outcome of the wrist are not clear. Our aim was to compare outcome of patients treated with early versus late motion protocol after volar plating. Methods: Thirty-three patients with distal radius fractures were prospectively and randomly enrolled into an early versus late motion study including volar plating of the distal radius fracture. Early motion included an active and passive wrist motion protocol by 14 days after surgery and delayed motion was initiated at 5 weeks. Fractures were defined as intra-articular and extra-articular, and those with, and without, ulnar styloid fracture. Motion and outcome scores (Disabilities of the Arm, Shoulder and Hand [DASH]/patient-rated wrist evaluation [PRWE]), and strength were measured through 1 year. Results: Wrist motion, DASH, and PRWE scores were only significantly different at 6 weeks with no significant differences at any later time points up to 1 year. One patient had complex regional pain syndrome (CRPS) and one had adhesive capsulitis in the late motion group. Conclusions: Following locked volar plating of distal radius fractures, early motion favored earlier return of motion along with lower DASH, PRWE, and pain scores within first 6 weeks. Although the late motion group had delayed recovery, there were no long-term significant differences in motion, strength, outcome, or pain scores. The 2 cases with complications (CRPS and adhesive capsulitis) did occur in the late motion group and may implicate late motion with these problems.


  • Dreaded Ulnar Wrist Pain: Long-term Results of Pisiformectomy for Painful Pisotriquetral Arthritis or Instability

    by Maureen A. O'Shaughnessy, Marco Rizzo, Steven L. Moran, Alexander Y. Shin, David G. Dennison, Bassem T. Elhassan

  • Outcome following Distally Locked Volar Plating for Distal Radius Fractures with Metadiaphyseal Involvement

    by Kristofer S. Matullo, David G. Dennison

    Background: The surgical treatment of metadiaphyseal distal radius fractures may be difficult due to the associated articular or periarticular extension that limits standard fixation techniques. Longer distal radius volar locking plates allow stable fixation of the distal fragments while providing standard plate fixation in the proximal radius. We hypothesize that this plating technique allows adequate fixation to both the distal radius and metadiaphyseal fragments. The purpose of the study is to describe the outcomes, radiographic parameters, secondary surgeries, and complication rate with this device. Methods: A retrospective chart review was conducted on adult patients with a distal radius fracture and metadiaphyseal involvement treated with a volar, distally locked plate. All patients were followed up for radiographic union, with a mean time of 219 days (range 38–575). Fracture patterns, outcomes of range of motion, grip strength, and complications, as well as injury, post open reduction and internal fixation (ORIF), and finally, healed radiographic parameters were recorded. Results: Twenty patients with 21 fractures were included. At union, mean radiographic parameters were the following: volar tilt of 8°, radial inclination of 27°, radial height of 14 mm, and ulnar variance of −1 mm. The mean final range of motion was 52° flexion, 50° extension, 68° pronation, and 66° supination. Complications included one infection and one plate removal. Four patients developed a nonunion requiring secondary procedures. There were no incidents of hardware failure or adhesions requiring tenolysis. Conclusion: Distally locked long volar plating for metadiaphyseal distal radius fractures is a safe and effective treatment option for these complex fracture patterns allowing anatomic restoration of the radial shaft and distal radius.


  • Distal Radius Fractures and the Volar Lunate Facet Fragment: Kirschner Wire Fixation in Addition to Volar-Locked Plating

    by Amy M. Moore, David G. Dennison

    Background: The volar lunate facet fragment of a distal radius fracture may not be stabilized with volar-locked plating alone due to the small size and distal location of the fragment. Identification and stabilization of this small fragment is critical as unstable fixation may result in radiocarpal and radioulnar joint subluxation. The addition of spring wire fixation with volar plating can provide stable internal fixation of this critical fracture fragment. Methods: A retrospective review (2006–2011) identified nine patients with distal radius fractures with an associated volar lunate facet fragment that were treated with volar-locked plating and spring wire fixation of the volar lunate facet fragment. Radiographic indices, range of motion, grip strength, and postoperative Patient-related wrist evaluation (PRWE) scores were obtained to assess pain and function. Results: All distal radius fractures healed, and the volar lunate facet fragment reduction was maintained. The mean follow-up was 54 weeks. Mean active range of motion was 46° wrist flexion, 51° wrist extension, 80° pronation, and 68° supination. The mean grip strength was 21 Kg, achieving 66 % of the uninjured limb. The average PRWE score was 17. No patient required removal of hardware or had evidence of tendon irritation. Conclusions: The addition of spring wire fixation to volar-locked plating provided stable fixation of the volar lunate facet fragment of distal radius fractures without complication. This technique addresses a limitation of volar-locked plating to control the small volar lunate facet fragment in distal radius fractures otherwise amenable to volar plating. Level of Evidence: A retrospective case series, Level IV.


    • 1 January 2010
      • Vol. 59, 525-38

    Acute trauma to the upper extremity: what to do and when to do it.

    by Jennifer Moriatis Wolf, George S Athwal, Alexander Y Shin, David G Dennison

    The management of acute trauma to the upper extremity includes the urgent treatment of injuries and the timing and choice of surgical stabilization and reconstruction. To evaluate and treat severe upper extremity trauma, the orthopaedic surgeon should understand the principles of emergency department and operating theater management of commonly seen traumatic injuries to the distal humerus, elbow, forearm, wrist, and hand. A review of the principles for treating these complex injuries, including principles of soft-tissue coverage, will aid surgeons in achieving the goal of providing optimal treatment for their patients.


    • 1 May 2009
      • Vol. 91  (5) , 1240-52

    Acute trauma to the upper extremity: what to do and when to do it.

    by Jennifer Moriatis Wolf, George S Athwal, Alexander Y Shin, David G Dennison


  • Fixed-Angle Volar Plate Fixation for Distal Radius Fractures in Immunosuppressed Patients

    by Erik D. Peterson, David G. Dennison

    The aim of this study was to define the outcome and complications following open reduction and internal fixed-angle plating of distal radius fractures for patients on chronic immunosuppression medications. A retrospective study identified 11 patients with distal radius fractures that had been on chronic immunosuppressive medication. The mean patient age was 59.9 years (40–82 years). According to the Orthopedic Trauma Association classification, there was one 23A3, one 23B3, and nine 23C type fractures. There were two open fractures. All patients received preoperative antibiotics and underwent reduction and fixation with a volar, fixed-angle plate. Postoperative measurements included postoperative and final radiographic indices, wrist flexion and extension, forearm rotation, and grip strength. Clinical follow-up averaged 13 months, and radiographic follow-up averaged 14.9 months. Statistical analysis was performed comparing means of various parameters with a two-sided t test with an alpha value ≤0.05. All fractures healed, and there were no infections. The final mean ulnar variance, volar tilt, and radial inclination were –0.1 mm (ulnar negative; –2.0 to +2.5 mm), 13° (5–23°), and 21° (15–27°), respectively. The mean articular gap or step was 0.4 mm. There was a small but significant decrease between the final and postoperative mean ulnar variance ( p=0.03). Mean wrist flexion was 47°, extension 47°, pronation 77°, and supination was 76°. Grip strength averaged 16.3 kg versus 25.1 kg for the opposite extremity. The one major complication included a postoperative carpal tunnel syndrome. Fixed-angle volar plate fixation for distal radius fractures in patients with chronic immunosuppression was associated with union (with acceptable radiographic alignment), no wound-healing problems or infections, and with functional wrist and forearm motion and grip strength.