Objective: To assess the reliability of radiographic measurement of angle of lateral opening (ALO) and angle of version of BFX acetabular cups.Study Design: In vitro radiographic study.Sample Population: BFX cups (24, 28, and 32 mm).Methods: Total hip replacement constructs (cups, 17 mm femoral head and a #7 CFX stem) were mounted on an inclinometer. Ventrodorsal radiographs were obtained with ALO varying between 21° and 70° and inclination set at 0°, 10°, 20°, and 30°. Radiographs were randomized using a random sequence generator. Three observers blinded to the radiograph order assessed ALO using 3 methods: (1) an ellipse method based on trigonometry; (2) using a measurement from the center of the femoral head to the truncated surface of the cup; (3) by visual estimation using a reference chart. Version was measured by assessing the ventral edge of the truncated surface.Results: ALO methods 2 and 3 were accurate and precise to within 10° and were significantly more accurate and precise than method 1 (P<.001). All methods were significantly less accurate with increasing inclination. Version measurement was accurate and precise to within 7° with 0–20° of inclination, but significantly less accurate with 30° of inclination.Conclusions: Methods 2 and 3, but not method 1, were sufficiently accurate and precise to be clinically useful. Version measurement was clinically useful when inclination was ≤20°.Keywords
This publication has 9 references indexed in Scilit:
- Evaluation of Functional Outcome After BFX®Total Hip Replacement Using a Pressure Sensitive WalkwayVeterinary Surgery, 2010
- Initial experience with a newly developed cementless hip endoprosthesisVeterinary and Comparative Orthopaedics and Traumatology, 2009
- Risk Factors for Ventral Luxation in Canine Total Hip ReplacementVeterinary Surgery, 2007
- Misinterpretation of cup anteversion in total hip arthroplasty using planar radiographyArchives of orthopaedic and trauma surgery, 2006
- Radiographic Evaluation of Acetabular Component Position in DogsVeterinary Surgery, 2001
- Definition and Determination of Acetabular Component Orientation in Cemented Total Hip ArthroplastyVeterinary Surgery, 2000
- Acetabular Component Orientation as an Indicator of Implant Luxation in Cemented Total Hip ArthroplastyVeterinary Surgery, 2000
- Evaluation of Risk Factors for Luxation After Total Hip Replacement in DogsVeterinary Surgery, 2000
- The canine cemented modular total hip prosthesisJournal of the American Animal Hospital Association, 1995