Clinical Evaluation of the Air Removal Characteristics of an Oxygenator with Integrated Arterial Filter in a Minimized Extracorporeal Circuit
- 21 April 2011
- journal article
- research article
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 34 (4) , 374-382
Abstract
The use of minimized extracorporeal circuits (MECC) in cardiac surgery is an important measure to increase the biocompatibility of cardiopulmonary bypass during coronary artery bypass grafting (CABG). These circuits eliminate volume storage reservoirs and bubble traps to minimize the circuit. However, the reduction in volume may increase the risk of gaseous microemboli (GME). The MECC system as used by our group consists of a venous bubble trap, centrifugal pump, and an oxygenator. To further reduce the risk of introducing GME, an oxygenator with an integrated arterial filter was developed based on the concept of minimal volume and foreign surface. We studied the air removal characteristics of this oxygenator with and without integrated arterial filter. The quantity and volume of GME were measured with precision at both the inlet and outlet of the devices. Our results showed that integration of an arterial filter into this oxygenator increased GME reducing capacity from 69.2% to 92%. Moreover, we were able to obtain data on the impact of an arterial filter on the exact size-distribution of GME entering the arterial line. The present study demonstrates that an MECC system and oxygenator with integrated arterial filter significantly reduces the volume and size of GME. The use of an integrated arterial filter in an MECC system may protect the patient from the deleterious effects of CPB and may further improve patient safety.Keywords
This publication has 28 references indexed in Scilit:
- Protecting the brain from gaseous and solid micro-emboli during coronary artery bypass grafting: a randomized controlled trialEuropean Heart Journal, 2009
- Dynamic bubble trap can replace an arterial filter during cardiopulmonary bypass surgeryPerfusion, 2006
- MicrobubblesChest, 2005
- Effect of perfusionist technique on cerebral embolization during cardiopulmonary bypassPerfusion, 2005
- Clinical experience with the mini-extracorporeal circulation system: an evolution or a revolution?The Annals of Thoracic Surgery, 2004
- Neuropsychologic impairment after coronary bypass surgery: Effect of gaseous microemboli during perfusionist interventionsThe Journal of Thoracic and Cardiovascular Surgery, 2001
- Gas EmbolismNew England Journal of Medicine, 2000
- Ex vivo testing of the Quart® arterial line filterPerfusion, 1999
- Cerebral microemboli during cardiopulmonary bypass: increased emboli during perfusionist interventionsThe Annals of Thoracic Surgery, 1999
- Intermittent antegrade warm blood cardioplegiaThe Annals of Thoracic Surgery, 1995