Single-Step Response and Determination of Power Components Mean Values of PES Using p-q Method during Transients
Open Access
- 16 November 2022
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 12 (22) , 11659
Abstract
This paper deals with the quasi-instantaneous determination of an apparent-, active-, and reactive (i.e., blind and distortion) power mean values, including total power factor, total harmonic distortion, and phase shift of fundamentals of power electronic system (PES) using the p-q method. The power components’ mean values are investigated both during transients and steady states. Using an integral calculus over one period and the moving average method (or digital filtering), the power components’ mean values can be determined within the next calculation step directly from phase current and voltage quantities. Consequently, with known values of a phase shift of fundamentals (using Fourier analysis), the power factor can be evaluated. The results of this study show how a distortion power component during transients is generated even under harmonic supplying and linear resistive-inductive load. The paper contains a theoretical base, modeling, and simulation for the 5-, 3-, and 2-phases of PES transients. A system compensated by switched capacitors as well as an active power filter shows a possibility to compensate for distortion and reactive power components in the next calculation step. Worked-out results can be used for the right determination and sizing of any PES. The presented approach brings the detailed time-waveform and improved quality of electrical quantities (time-waveforms), and through quasi-instantaneous (single step) response time of compensation, minimizes nascent overvoltage of the system.Keywords
This publication has 18 references indexed in Scilit:
- Instantaneous Power Theory and Applications to Power Conditioning2017
- What is wrong with the conservative power theory (CPT)2016
- Analytic Method for the Computation of the Total Harmonic Distortion by the Cauchy Method of ResiduesIEEE Transactions on Communications, 2011
- Effect of supply voltage asymmetry on IRP p – q -based switching compensator controlIET Power Electronics, 2010
- Instantaneous Reactive Power Theory: A Reference in the Nonlinear Loads CompensationIEEE Transactions on Industrial Electronics, 2009
- Sliding DFT Control Algorithm for Three-Phase Active Power Filter2006
- Control techniques for active power filtersIEE Proceedings - Electric Power Applications, 2005
- Power Electronic Control in Electrical Systems2002
- An instantaneous active and reactive current component method for active filtersIEEE Transactions on Power Electronics, 2000