Abstract
Unbalanced phase inductance due to Stator Inter-Turn Faults (SITF) significantly affects the accuracy of sensorless rotor position estimation in Synchronous Reluctance Motors (SynRMs). Traditional sensorless estimation schemes assume balanced inductance and often fail under fault conditions. This paper presents a modified inductance-based position estimation method that accounts for unbalanced inductance variations. The proposed method introduces an Adaptive Fault-Tolerant Inductance Segmentation (AFTIS) approach to identify and compensate for phase inductance deviations. Theoretical analysis is provided to quantify the position estimation error introduced by inductance imbalance. The method is validated through finite element simulations and experimental results on a SynRM prototype, demonstrating significant effectiveness under faulty conditions. The proposed scheme enhances the fault tolerance of sensorless SynRM drives without requiring additional sensors or complex computational resources.

This publication has 19 references indexed in Scilit: