VBVijay. B. Borghate

Vijay. B. Borghate

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Vijay. B. Borghate has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Fault-Tolerant Sensorless Position Estimation for Synchronous Reluctance Motor Under Stator Inter-Turn Faults

    by Sonalika Singh, Ritesh Kumar Keshri, Vijay B. Borghate

    Unbalanced phase inductance due to Stator Inter-Turn Faults (SITF) significantly affects the accuracy of sensorless rotor position estimation in Synchronous Reluctance Motors (SynRMs). Traditional sensorless estimation schemes assume balanced inductance and often fail under fault conditions. This paper presents a modified inductance-based position estimation method that accounts for unbalanced inductance variations. The proposed method introduces an Adaptive Fault-Tolerant Inductance Segmentation (AFTIS) approach to identify and compensate for phase inductance deviations. Theoretical analysis is provided to quantify the position estimation error introduced by inductance imbalance. The method is validated through finite element simulations and experimental results on a SynRM prototype, demonstrating significant effectiveness under faulty conditions. The proposed scheme enhances the fault tolerance of sensorless SynRM drives without requiring additional sensors or complex computational resources.

  • Hybrid Sensorless Speed Control of SynRM Based on Dynamic and Reluctance Equivalent Back EMF Models for Wide‐Speed–Range Operation

    by Sonalika Singh, Ritesh Kumar Keshri, Suman Saurav, Vijay B. Borghate

    This paper proposes a hybrid sensorless speed control strategy for synchronous reluctance motors (SynRMs) that operates over a wide‐speed range without requiring mechanical sensors to estimate rotor position. The work proposes a two‐region estimation framework: A dynamic inductance (DYI) model is employed in the low‐speed region to estimate rotor position. In contrast, a Reluctance Equivalent Back (REB) EMF model is utilized in the high‐speed region. A smooth transition between the two estimation modes is achieved with a speed‐based switching strategy. A full FEM simulation and experimental results on a lab prototype demonstrate that the method operates properly. The results show that the estimation is accurate, and that the dynamic performance is smooth across the entire operating speed range. The nomenclature used throughout this paper is provided after the Conclusion section.

  • Enhanced Protection of Grid-Connected Solid-State Transformers Against Sympathetic Inrush Current

    by Saurabh Kamble, Pradyumn Chaturvedi, Ching-Jan Chen, V. B. Borghate

    The transition from line frequency transformers (LFT) to solid-state transformers (SST) in modern distribution systems introduces new challenges, particularly in managing sympathetic inrush current (SIC). This current, often ranging from 1.5 to 10 times the rated current, induces overcurrent stresses on the SST's semiconductor switches, potentially compromising the system's reliability. However, the existing body of research offers limited insight into the effects of SIC on SST performance, leaving a critical gap in the understanding of these phenomena during grid events. This paper addresses this gap by analyzing the impact of SIC on SSTs and developing a mathematical model to simulate SIC events in grid-connected SSTs. Through this model, the relationship between the peak value of the SST input current and the phase shift angle ($\phi$) of high-frequency transformer (HFT) voltages is established, providing key insights into the root causes of overcurrent stresses. To mitigate these stresses, a novel Phase Shift Angle Control (PSAC) algorithm is proposed. This technique dynamically calculates the second harmonic during SIC events on a per-cycle basis, enabling precise control and effective mitigation of the current surge. The PSAC algorithm's effectiveness is demonstrated through both MATLAB simulations and experimental validation. Results show a significant reduction in SIC from 12.96 A to 8.1 A in simulations, and from 25 A to 2.5 A in experimental tests, aligning the current with rated levels. The findings suggest that the proposed PSAC technique is a robust solution for protecting SSTs from the adverse effects of SIC, thereby enhancing their operational resilience and reliability in modern power distribution systems.


  • Open Access

    Pole-Phase Modulation of Symmetrical 6-Phase Induction Motor Drive for Electric Vehicle With 1:2 Speed Control

    by S. V. Umredkar, R. Keshri, V. B. Borghate, M. M. Renge

    The symmetrical 6-terminal pole-phase modulation (S6TPPM) induction motor drive (IMDrive) has proven to be a viable alternative to other drives in electrical vehicles (EVs). The advantages of IMDrive combined with pole-phase modulation (PPM) provide the flexibility to expand the torque-speed range, enabling such drives to work efficiently under different driving conditions for EVs. An earlier study proposed a new winding pattern with three slots per pole per phase (3SPP) coupled with a preconfigured excitation pattern to help achieve high-pole and low-pole operations. However, there is a need to better control the pole-phase switching and acceleration of the drive. This study focuses on acceleration control over the 4-pole/1500 rpm and 2-pole/ 3000 rpm modes to achieve fast acceleration with high-torque and high-speed with low-torque required for the initial start and cruising respectively. Mathematical modeling based on the space vector theory to control S6TPPM IMDrive is presented. The dsPIC (digital signal controller) microcontroller-based voltage to frequency (V/f) control technique was employed to obtain manual control over the speed and torque of the drive and to keep the experimental setup simple as precision control is beyond the scope of the current study. The observations and results from the experiment show control of the speed of the IMDrive from 300 rpm to 3000 rpm and vice-versa.


  • Improving DC-Bus Voltage Regulation in Grid Fed EV Fast Charging Station Using MLI Based DVR

    by S. Manmadha Rao, R. J. Satputaley, R. K. Keshri, V. B. Borghate, Anurag Khergade

    This article presents a T-type 5-level inverter based dynamic voltage restorer (DVR) as a power quality (PQ) solution to enhance DC-bus voltage regulation in grid fed electric vehicle fast charging stations (EVFCS). The designing of DVR connected EVFCS is carried out in this work. There is a noticeable impact of EV loading on EVFCS performance. To observe the effect of EVs loading on DC-bus, three Li-ion battery packs are used. The performance of closed loop current regulated buck converters is examined for various loading scenarios. Further, the impact of EVs loading on several EVFCS parameters, including DC-bus voltage, charging current, battery SOC and battery voltage is examined in simulation. A closed loop voltage controller based on the αβ to dq transformation is constructed for 1-φ DVR in order to reduce the loading effect of EVs. This DVR maintains the rated DC-bus voltage (110 V), guaranteeing proper voltage regulation and the rated current of each battery under all three loading scenarios. Additionally, the DVR protects the point of common coupling (PCC) from voltage harmonics generated by EVFCS and maintains it within the IEEE 519 limit. Finally, to validate the simulation results, an experimental study is also carried out on reduced scale with a T-type 5-level DVR to observe the improved performance of EVFCS.


  • Design and Implementation of Three Phase TCHB-Based DVR

    by Rajshri Satputaley, V. B. Borghate, Anurag Khergade, Ashwin Dhabale, S. K. Patro


  • A Level Enhanced Nearest Level Control for Modular Multilevel Converter Without Using Sensors

    by Hari Babu Gobburi, Vijay. B. Borghate, Prafullachandra M. Meshram

    Modular Multilevel Converters (MMCs) have gained popularity in high and medium power applications. The nearest level control (NLC) is the suitable modulation technique as it offers low switching loss and easier implementation compared to the carrier-based pulse width modulation techniques. However, the harmonic performance is poor in case of MMC with low number of submodules (SMs). Apart from this, the SM capacitor voltage balance control is crucial, which demands expensive voltage and current measurement boards with conventional balancing approaches. This article presents a level enhanced NLC method for MMC. The proposed method derives the necessary switching patterns using simple logical operations based on the inherent property of NLC reference waveform. By which, equal insertion and bypass periods are ensured for the SM capacitors and eliminated the voltage and current sensors needed for the capacitor voltage balance control. Also, the output voltage level number increases to 2 N +1 (where N is the number of SMs per arm) with reduced half step size. Hence, the quality of ac output waveform can be improved with low number of SMs. The proposed method is verified by simulations in MATLAB/SIMULINK software, and for the validation, experimental results are presented.


  • Reliable Multilevel Inverter Topology using two DC Sources.

    by Shubham T. Kamble, Hari Babu Gobburi, V. B. Borghate

    The proposed reliable multi-level inverter with the fault tolerant operation. The topology is with an asymmetrical source combination and the source ratio is 3:1. Under normal conditions, the topology develops a nine-level output voltage waveform with eight switches in which seven switches are unidirectional and one switch is bidirectional. The open-circuit fault is the most common fault which occurs due to the fault in the gate drive circuit. The magnitude of output voltage and level fall from nine to the five level when the fault occurs in the unidirectional switches and output voltage falls to three level when the fault is in the bi-directional switch. To maintain rated output voltage, the tap-changing transformer is placed between the inverter output and load. The presented multilevel inverter topology is simulated in MATLAB Simulink.

  • Sensorless voltage balancing method for modular multilevel converter

    by Hari Babu Gobburi, Vijay B. Borghate, Prafullachandra M. Meshram

    Modular multilevel converters (MMCs) have become prominent for high and medium power applications. The phase‐disposition pulse width modulation (PDPWM) technique is a carrier‐based method that generates good quality output. However, it has the inherent problem of uneven power distribution. Conventionally, this is solved by expensive voltage and current measurements. In this paper, a capacitor voltage balancing method is presented for MMC, which eliminates the need for voltage and current sensors. It also ensures uniform power distribution among the submodules (SMs). In addition, it needs only one carrier per phase, and one PWM reference, for either upper arm or lower arm to produceN + 1 level withNSMs per arm. The capacitor voltage balancing method is analyzed mathematically and verified for the MMC with two‐level half‐bridge SMs. The same method is also extended to the MMC with three‐level flying capacitor SMs. MATLAB/SIMULINK simulations and experimental results on a laboratory prototype are presented to verify the theoretical concepts.


  • A Review on Strategies to Control Frequency Variation in Deviation Settlement Mechanism

    by Srikant R. Sabbanwar, Rajshri J. Satputaley, Vijay B. Borghate

    Availability based tariff (ABT) came into power in India to overcome stability issues of grid. The grid was undisciplined due to large variation of power frequency due to unscheduled over injection and under injection of power without worrying about the frequency. However, the ABT was introduced to increase the generation capacity of grid but it has been slowly adopted as profit making system. Now, (Deviation Settlement Mechanism) DSM has been introduced in India as a frequency-based technique and does not depends on any real world market conditions. The frequency deviation describes the over/ under injection of power that feeds to DSM penalty. This review paper deals with the recent studies carried out in drawing down the strategies to discourage deviation (frequency) from schedule, operation within frequency band and by ensuring grid security. In addition to this, a basic control strategy has also been reviewed that can be adopted in implementing a topology for control over frequency variation from generation end. This paper deals with the basic discussions over implementation of DSM as per guidelines of CERC and MERC and few possible power devices and its methods to control frequency variation based on some past researches.