Novel Force Measurement System for Soft Tissue Balance in Total Knee Arthroplasty Based on Flexible Pressure Sensor Arrays
Open Access
- 7 January 2022
- journal article
- research article
- Published by Wiley in Advanced Intelligent Systems
- Vol. 4 (4) , 2100156
Abstract
Total knee arthroplasty (TKA) is a common treatment for terminal knee arthropathy. Soft tissue balance is one of the key factors affecting the success rate of TKA. However, current measurement systems still face great challenges in terms of accuracy and timeliness. Herein, a novel force measurement system based on a smart spacer is proposed to measure soft tissue balance in a timely and accurate manner. The smart spacer is designed according to the simulated results, where six flexible pressure sensors with a high sensitivity of 99.56 N−1 and a wide detection range of 50 N are attached to the spacer base to directly detect the soft tissue balance force. Moreover, a soft tissue balance measurement system is constructed, which can measure the force at different positions, such as the extension position (0°), the middle position (45°), and the flexion position (90°), and display them on the computer in a timely manner. This novel real‐time knee soft tissue balance measurement system provides a way for surgeons or knee joint replacement surgery robots to accurately evaluate soft tissue balance and paves the way for improving the success rate of TKA and the patient's postoperative rehabilitation.Keywords
Funding Information
- National Natural Science Foundation of China (61773372, 62173240, 62073229, U1713218)
This publication has 43 references indexed in Scilit:
- Effect of intraoperative soft tissue balance on postoperative recovery of ambulatory and balancing function in posterior-stabilized total knee arthroplastyJournal of Orthopaedic Science, 2019
- The Learning Curve by Operative Time for Soft Tissue Balancing in Total Knee Arthroplasty Using Electronic Sensor TechnologyThe Journal of Arthroplasty, 2019
- How Accurately Can Soft Tissue Balance Be Determined in Total Knee Arthroplasty?The Journal of Arthroplasty, 2019
- Analysis of differences in laxities and neutral positions from native after kinematically aligned TKA using cruciate retaining implantsJournal of Orthopaedic Research, 2018
- Stretchable capacitive fabric electronic skin woven by electrospun nanofiber coated yarns for detecting tactile and multimodal mechanical stimuliJournal of Materials Chemistry C, 2018
- Contact forces in the tibiofemoral joint from soft tissue tensions: Implications to soft tissue balancing in total knee arthroplastyJournal of Biomechanics, 2017
- Design and evaluation of an actuated knee implant for postoperative ligament imbalance correctionMedical Engineering & Physics, 2016
- Design and test of a MEMS strain-sensing device for monitoring artificial knee implantsBiomedical Microdevices, 2013
- Design and test of an autonomous sensor for force measurements in human knee implantsSensors and Actuators A: Physical, 2010
- 1-Dimensional structures of poly(3,4-ethylenedioxythiophene)(PEDOT): a chemical route to tubes, rods, thimbles, and beltsChemical Communications, 2005