Accuracy and sensitivity of three-dimensional echocardiography to detect changes in right ventricular volumes: comparison study with cardiac magnetic resonance
Authors:
- 10 September 2020
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 37 (2) , 493-502
Abstract
We aimed to investigate the ability of three-dimensional transthoracic echocardiography (3DE) to detect changes in RV volumes compared to cardiac magnetic resonance (CMR). Eighty-five subjects including 45 with no known cardiac disease and 40 patients with a variety of cardiac diseases were included. Two- and three-dimensional echocardiography as well as CMR of the RV was performed before and after infusion of on average two litres of saline. Examinations were analysed with estimation of RV dimensions, volumes and ejection fraction (RVEF). Intra- and inter-examiner variability was evaluated in 25 patients randomly selected from the cohort. Three-dimensional echocardiography underestimated volumes and RVEF compared to CMR with mean differences and 95% limits of agreement of 110.3 ± 59 mL for RV end-diastolic volume (RVEDV), 43.3 ± 32 mL for RV end-systolic volume (RVESV) and 3.5 ± 10.7% for RVEF. CMR was more reproducible than 3DE, with intra-observer coefficient of variation (CV) of 4% vs. 14.2% for RVEDV, 9.7% vs. 16.7% for RVESV and 6.3% vs. 8.6% for RVEF. The RVEDV, RVESV and RV stroke volume (RVSV) by CMR significantly increased after saline infusion by 15.3 ± 16.2 mL, 3.5 ± 14.2 mL and 11.8 ± 12.6 mL, respectively, as well as RVEF by 1.5 ± 4.6% (p < 0.05). However, 3DE was not able to detect any of these changes in RV volumes (p ≥ 0.05). Compared to CMR imaging of the RV, three-dimensional echocardiography appears unable and unreliable in detecting RV volume changes of less than 15%, highlighting the need for cautious utility of 3DE in these circumstances.Keywords
This publication has 27 references indexed in Scilit:
- A Randomized, Controlled, Double-Blind Crossover Study on the Effects of 2-L Infusions of 0.9% Saline and Plasma-Lyte® 148 on Renal Blood Flow Velocity and Renal Cortical Tissue Perfusion in Healthy VolunteersAnnals of Surgery, 2012
- Manual correction of semi-automatic three-dimensional echocardiography is needed for right ventricular assessment in adults; validation with cardiac magnetic resonanceCardiovascular Ultrasound, 2012
- 3D Echo systematically underestimates right ventricular volumes compared to cardiovascular magnetic resonance in adult congenital heart disease patients with moderate or severe RV dilatationJournal of Cardiovascular Magnetic Resonance, 2011
- Accuracy of Right Ventricular Volumes and Function Determined by Three-Dimensional Echocardiography in Comparison with Magnetic Resonance Imaging: A Meta-Analysis StudyJournal of the American Society of Echocardiography, 2010
- ESC Guidelines for the management of grown-up congenital heart disease (new version 2010): The Task Force on the Management of Grown-up Congenital Heart Disease of the European Society of Cardiology (ESC)European Heart Journal, 2010
- Prognostic Value of Right Ventricular Function in Patients After Acute Myocardial Infarction Treated With Primary Percutaneous Coronary InterventionCirculation: Cardiovascular Imaging, 2010
- Diagnosis of arrhythmogenic right ventricular cardiomyopathy/dysplasia: Proposed Modification of the Task Force CriteriaEuropean Heart Journal, 2010
- Multimodality Noninvasive Imaging for Assessment of Congenital Heart DiseaseCirculation: Cardiovascular Imaging, 2010
- Accuracy of guideline recommendations for two-dimensional quantification of the right ventricle by echocardiographyThe International Journal of Cardiovascular Imaging, 2008
- Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonanceEuropean Heart Journal, 2006