In-vitro comparison of LC-DCP- and LCP-constructs in the femur of newborn calves – a pilot study
Open Access
- 21 August 2012
- journal article
- research article
- Published by Springer Nature in BMC Veterinary Research
- Vol. 8 (1) , 139
Abstract
Background: To compare the biomechanical in-vitro characteristics of limited-contact dynamic compression plate (LC-DCP) and locking compression plate (LCP) constructs in an osteotomy gap model of femoral fracture in neonatal calves. Pairs of intact femurs from 10 calves that had died for reasons unrelated to the study were tested. A 7-hole LC-DCP with six 4.5 mm cortical screws was used in one femur and a 7-hole LCP with four 5.0 mm locking and two 4.5 mm cortical screws was used in the corresponding femur. The constructs were tested to failure by cyclic compression at a speed of 2 mm/s within six increasing force levels.Results: The bone-thread interface was stripped in 21 of 80 cortical screws (26.3%) before a pre-set insertion torque of 3 Nm was achieved. Only 3 corresponding intact pairs of constructs could be statistically compared for relative structural stiffness, actuator excursion and width of the osteotomy gap. Relative structural stiffness was significantly greater, actuator excursion and width of the osteotomy gap were significantly smaller in the LCP constructs. While failure occurred by loosening of the screws in the LC-DCP constructs, locking constructs failed by cutting large holes in the soft distal metaphyseal bone.Conclusions: An insertion torque sufficient to provide adequate stability in femurs of newborn calves could not be achieved reliably with 4.5 mm cortical screws. Another limiting factor for both constructs was the weak cancellous bone of the distal fracture fragment. LCP constructs were significantly more resistant to compression than LC-DCP constructs.Keywords
This publication has 31 references indexed in Scilit:
- Use of a novel intramedullary nail for femoral fracture repair in calves: 25 cases (2008–2009)Journal of the American Veterinary Medical Association, 2011
- Femoral diaphysis fractures in cattle: 26 cases (1994–2005)Australian Veterinary Journal, 2010
- Far Cortical Locking Can Reduce Stiffness of Locked Plating Constructs While Retaining Construct StrengthJournal of Bone and Joint Surgery, 2009
- Distal Femoral Fixation: A Biomechanical Comparison of Trigen Retrograde Intramedullary (I.M.) Nail, Dynamic Condylar Screw (DCS), and Locking Compression Plate (LCP) Condylar PlateJournal of Trauma: Injury, Infection & Critical Care, 2009
- Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysisClinical Biomechanics, 2009
- A Mechanical Comparison of the Locking Compression Plate (LCP) and the Low Contact-Dynamic Compression Plate (DCP) in an Osteoporotic Bone ModelJournal of Orthopaedic Trauma, 2008
- Assessment of Stiffness and Strength of 4 Different Implants Available for Equine Fracture Treatment: A Study on a 20° Oblique Long‐Bone Fracture Model Using a Bone SubstituteVeterinary Surgery, 2005
- Locking Compression Plate Loosening and Plate BreakageJournal of Orthopaedic Trauma, 2004
- Femoral and tibial fractures in a newborn calf after transplacental infection with bovine viral diarrhoea virusVeterinary Record, 1993
- Long Bone Fractures in Large Animals A Retrospective StudyVeterinary Surgery, 1985