Mona Hoerdemann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mona Hoerdemann has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Carola Sauter-Louis
Clinic for Ruminants with Ambulatory and Herd Health Services at the Centre for Clinical Veterinary Medicine, Ludwig-Maximilians-Universitaet Muenchen, Oberschleissheim, Germany
1 shared publication - Karl Nuss
Department of Farm Animals, Vetsuisse Faculty, University of Zurich, 8057 Zurich, Switzerland
1 shared publication - Philippe Gédet
Institute for Surgical Technology and Biomechanics, University of Berne, Berne, Switzerland
1 shared publication - Stephen J. Ferguson
Future Health Technologies, Singapore-ETH Centre, Campus for Research Excellence And Technological Enterprise (CREATE)
1 shared publication
Latest Publications
- Open Access
- 21 August 2012
- Published by Springer Nature in BMC Veterinary Research
- Vol. 8 (1) , 139
In-vitro comparison of LC-DCP- and LCP-constructs in the femur of newborn calves – a pilot study
Background: To compare the biomechanical in-vitro characteristics of limited-contact dynamic compression plate (LC-DCP) and locking compression plate (LCP) constructs in an osteotomy gap model of femoral fracture in neonatal calves. Pairs of intact femurs from 10 calves that had died for reasons unrelated to the study were tested. A 7-hole LC-DCP with six 4.5 mm cortical screws was used in one femur and a 7-hole LCP with four 5.0 mm locking and two 4.5 mm cortical screws was used in the corresponding femur. The constructs were tested to failure by cyclic compression at a speed of 2 mm/s within six increasing force levels.Results: The bone-thread interface was stripped in 21 of 80 cortical screws (26.3%) before a pre-set insertion torque of 3 Nm was achieved. Only 3 corresponding intact pairs of constructs could be statistically compared for relative structural stiffness, actuator excursion and width of the osteotomy gap. Relative structural stiffness was significantly greater, actuator excursion and width of the osteotomy gap were significantly smaller in the LCP constructs. While failure occurred by loosening of the screws in the LC-DCP constructs, locking constructs failed by cutting large holes in the soft distal metaphyseal bone.Conclusions: An insertion torque sufficient to provide adequate stability in femurs of newborn calves could not be achieved reliably with 4.5 mm cortical screws. Another limiting factor for both constructs was the weak cancellous bone of the distal fracture fragment. LCP constructs were significantly more resistant to compression than LC-DCP constructs.
- 21 August 2012
- Published by Springer Nature in BMC Veterinary Research
- Vol. 8 (1) , 139
Open AccessIn-vitro comparison of LC-DCP- and LCP-constructs in the femur of newborn calves – a pilot study
Background: To compare the biomechanical in-vitro characteristics of limited-contact dynamic compression plate (LC-DCP) and locking compression plate (LCP) constructs in an osteotomy gap model of femoral fracture in neonatal calves. Pairs of intact femurs from 10 calves that had died for reasons unrelated to the study were tested. A 7-hole LC-DCP with six 4.5 mm cortical screws was used in one femur and a 7-hole LCP with four 5.0 mm locking and two 4.5 mm cortical screws was used in the corresponding femur. The constructs were tested to failure by cyclic compression at a speed of 2 mm/s within six increasing force levels.Results: The bone-thread interface was stripped in 21 of 80 cortical screws (26.3%) before a pre-set insertion torque of 3 Nm was achieved. Only 3 corresponding intact pairs of constructs could be statistically compared for relative structural stiffness, actuator excursion and width of the osteotomy gap. Relative structural stiffness was significantly greater, actuator excursion and width of the osteotomy gap were significantly smaller in the LCP constructs. While failure occurred by loosening of the screws in the LC-DCP constructs, locking constructs failed by cutting large holes in the soft distal metaphyseal bone.Conclusions: An insertion torque sufficient to provide adequate stability in femurs of newborn calves could not be achieved reliably with 4.5 mm cortical screws. Another limiting factor for both constructs was the weak cancellous bone of the distal fracture fragment. LCP constructs were significantly more resistant to compression than LC-DCP constructs.