Comparing a Fully Automated Cephalometric Tracing Method to a Manual Tracing Method for Orthodontic Diagnosis
Open Access
- 20 November 2022
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (22) , 6854
Abstract
Background: This study aims to compare an automated cephalometric analysis based on the latest deep learning method of automatically identifying cephalometric landmarks with a manual tracing method using broadly accepted cephalometric software. Methods: A total of 100 cephalometric X-rays taken using a CS8100SC cephalostat were collected from a private practice. The X-rays were taken in maximum image size (18 × 24 cm lateral image). All cephalometric X-rays were first manually traced using the Dolphin 3D Imaging program version 11.0 and then automatically, using the Artificial Intelligence CS imaging V8 software. The American Board of Orthodontics analysis and the European Board of Orthodontics analysis were used for the cephalometric measurements. This resulted in the identification of 16 cephalometric landmarks, used for 16 angular and 2 linear measurements. Results: All measurements showed great reproducibility with high intra-class reliability (>0.97). The two methods showed great agreement, with an ICC range of 0.70–0.92. Mean values of SNA, SNB, ANB, SN-MP, U1-SN, L1-NB, SNPg, ANPg, SN/ANS-PNS, SN/GoGn, U1/ANS-PNS, L1-APg, U1-NA, and L1-GoGn landmarks had no significant differences between the two methods (p > 0.0027), while the mean values of FMA, L1-MP, ANS-PNS/GoGn, and U1-L1 were statistically significantly different (p < 0.0027). Conclusions: The automatic cephalometric tracing method using CS imaging V8 software is reliable and accurate for all cephalometric measurements.Keywords
This publication has 33 references indexed in Scilit:
- Ror2 signaling regulates Golgi structure and transport through IFT20 for tumor invasivenessScientific Reports, 2017
- Fully automated quantitative cephalometry using convolutional neural networksJournal of Medical Imaging, 2017
- Fully Automatic System for Accurate Localisation and Analysis of Cephalometric Landmarks in Lateral CephalogramsScientific Reports, 2016
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Evaluation and Comparison of Anatomical Landmark Detection Methods for Cephalometric X-Ray Images: A Grand ChallengeIEEE Transactions on Medical Imaging, 2015
- 3D Microendoscopic Electrical Impedance Tomography for Margin Assessment During Robot-Assisted Laparoscopic ProstatectomyIEEE Transactions on Medical Imaging, 2015
- Reliability of four different computerized cephalometric analysis programsEuropean Journal of Orthodontics, 2011
- Evaluation of speed, repeatability, and reproducibility of digital radiography with manual versus computer-assisted cephalometric analysesEuropean Journal of Orthodontics, 2009
- A comparison of manual traced images and corresponding scanned radiographs digitally tracedEuropean Journal of Orthodontics, 2009
- Enhanced speed and precision of measurement in a computer-assisted digital cephalometric analysis system.The Angle Orthodontist, 2004