Small Blob Detector Using Bi-Threshold Constrained Adaptive Scales
- 23 August 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (9) , 2654-2665
Abstract
Recent advances in medical imaging technology bring great promises for medicine practices. Imaging biomarkers are discovered to inform disease diagnosis, prognosis, and treatment assessment. Detecting and segmenting objects from images are often the first steps in quantitative measurement of these biomarkers. The challenges of detecting objects in images, particularly small objects known as blobs, include low image resolution, image noise and overlap among the blobs. This research proposes a Bi-Threshold Constrained Adaptive Scale (BTCAS) blob detector to uncover the relationship between the U-Net threshold and the Difference of Gaussian (DoG) scale to derive a multi-threshold, multi-scale small blob detector. With lower and upper bounds on the probability thresholds from U-Net, two binarized maps of the distance are rendered between blob centers. Each blob is transformed to a DoG space with an adaptively identified local optimum scale. A Hessian convexity map is rendered using the adaptive scale, and the under-segmentation typical of the U-Net is resolved. To validate the performance of the proposed BTCAS, a 3D simulated dataset (n = 20) of blobs, a 3D MRI dataset of human kidneys and a 3D MRI dataset of mouse kidneys, are studied. BTCAS is compared against four state-of-the-art methods: HDoG, U-Net with standard thresholding, U-Net with optimal thresholding, and UH-DoG using precision, recall, F-score, Dice and IoU. We conclude that BTCAS statistically outperforms the compared detectors.Keywords
Funding Information
- National Institute of Health (R01DK110622, R01DK111861)
- Bruker ClinScan 7T MRI
- Molecular Imaging Core
- NIH (1S10RR019911-01)
- School of Medicine, University of Virginia
This publication has 47 references indexed in Scilit:
- Phenotyping by magnetic resonance imaging nondestructively measures glomerular number and volume distribution in mice with and without nephron reductionKidney International, 2016
- Benign and malignant breast tumors classification based on region growing and CNN segmentationExpert Systems with Applications, 2015
- Methods and Challenges in Quantitative Imaging Biomarker DevelopmentAcademic Radiology, 2015
- Multimodal Neuroimaging Feature Learning for Multiclass Diagnosis of Alzheimer's DiseaseIEEE Transactions on Biomedical Engineering, 2014
- Small Blob Identification in Medical Images Using Regional Features From Optimum ScaleIEEE Transactions on Biomedical Engineering, 2014
- MRI-based glomerular morphology and pathology in whole human kidneysAmerican Journal of Physiology-Renal Physiology, 2014
- Computer-Aided Detection of Prostate Cancer in MRIIEEE Transactions on Medical Imaging, 2014
- Mitosis Detection in Breast Cancer Histology Images with Deep Neural Networks2013
- Measuring glomerular number and size in perfused kidneys using MRIAmerican Journal of Physiology-Renal Physiology, 2011
- MRI of the basement membrane using charged nanoparticles as contrast agentsMagnetic Resonance in Medicine, 2008