Yanzhe Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yanzhe Xu has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Teresa Wu
Arizona State University
8 shared publications - Hyunsoo Yoon
Department of Industrial Engineering, Yonsei University, Seoul, Republic of Korea
4 shared publications Kevin M. Bennett
Department of Radiology, Washington University, USA
4 shared publicationsTeresa Wu
ASU-Mayo Center for Innovative Imaging, School of Computing, Informatics, Decision Systems Engineering, Arizona State University, Tempe, Arizona, USA
4 shared publicationsFei Gao
School of Computing, Informatics, and Decision Systems Engineering, Arizona State University, 699S Mill Ave, Tempe, AZ, 85281, USA
3 shared publications- Fei Gao
Informatics and Decision Systems Engineering and ASU-Mayo Center for Innovative Imaging, School of Computing, Arizona State University, USA
3 shared publications
Latest Publications
- Open Access
- 29 November 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (12) , 1372
BlobCUT: A Contrastive Learning Method to Support Small Blob Detection in Medical Imaging
Medical imaging-based biomarkers derived from small objects (e.g., cell nuclei) play a crucial role in medical applications. However, detecting and segmenting small objects (a.k.a. blobs) remains a challenging task. In this research, we propose a novel 3D small blob detector called BlobCUT. BlobCUT is an unpaired image-to-image (I2I) translation model that falls under the Contrastive Unpaired Translation paradigm. It employs a blob synthesis module to generate synthetic 3D blobs with corresponding masks. This is incorporated into the iterative model training as the ground truth. The I2I translation process is designed with two constraints: (1) a convexity consistency constraint that relies on Hessian analysis to preserve the geometric properties and (2) an intensity distribution consistency constraint based on Kullback-Leibler divergence to preserve the intensity distribution of blobs. BlobCUT learns the inherent noise distribution from the target noisy blob images and performs image translation from the noisy domain to the clean domain, effectively functioning as a denoising process to support blob identification. To validate the performance of BlobCUT, we evaluate it on a 3D simulated dataset of blobs and a 3D MRI dataset of mouse kidneys. We conduct a comparative analysis involving six state-of-the-art methods. Our findings reveal that BlobCUT exhibits superior performance and training efficiency, utilizing only 56.6% of the training time required by the state-of-the-art BlobDetGAN. This underscores the effectiveness of BlobCUT in accurately segmenting small blobs while achieving notable gains in training efficiency.
- 29 November 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (12) , 1372
Open AccessBlobCUT: A Contrastive Learning Method to Support Small Blob Detection in Medical Imaging
Medical imaging-based biomarkers derived from small objects (e.g., cell nuclei) play a crucial role in medical applications. However, detecting and segmenting small objects (a.k.a. blobs) remains a challenging task. In this research, we propose a novel 3D small blob detector called BlobCUT. BlobCUT is an unpaired image-to-image (I2I) translation model that falls under the Contrastive Unpaired Translation paradigm. It employs a blob synthesis module to generate synthetic 3D blobs with corresponding masks. This is incorporated into the iterative model training as the ground truth. The I2I translation process is designed with two constraints: (1) a convexity consistency constraint that relies on Hessian analysis to preserve the geometric properties and (2) an intensity distribution consistency constraint based on Kullback-Leibler divergence to preserve the intensity distribution of blobs. BlobCUT learns the inherent noise distribution from the target noisy blob images and performs image translation from the noisy domain to the clean domain, effectively functioning as a denoising process to support blob identification. To validate the performance of BlobCUT, we evaluate it on a 3D simulated dataset of blobs and a 3D MRI dataset of mouse kidneys. We conduct a comparative analysis involving six state-of-the-art methods. Our findings reveal that BlobCUT exhibits superior performance and training efficiency, utilizing only 56.6% of the training time required by the state-of-the-art BlobDetGAN. This underscores the effectiveness of BlobCUT in accurately segmenting small blobs while achieving notable gains in training efficiency.
- Open Access
- 28 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (15) , 7599
GAN Training Acceleration Using Fréchet Descriptor-Based Coreset
Generative Adversarial Networks (GANs) are a class of deep learning models being applied to image processing. GANs have demonstrated state-of-the-art performance in applications such as image generation and image-to-image translation, just to name a few. However, with this success comes the realization that the training of GANs takes a long time and is often limited by available computing resources. In this research, we propose to construct a Coreset using Fréchet Descriptor Distances (FDD-Coreset) to accelerate the training of GAN for blob identification. We first propose a Fréchet Descriptor Distance (FDD) to measure the difference between each pair of blob images based on the statistics derived from blob distribution. The Coreset is then employed using our proposed FDD metric to select samples from the entire dataset for GAN training. A 3D-simulated dataset of blobs and a 3D MRI dataset of human kidneys are studied. Using computation time and eight performance metrics, the GAN trained on the FDD-Coreset is compared against the model trained on the entire dataset and an Inception and Euclidean Distance-based Coreset (IED-Coreset). We conclude that the FDD-Coreset not only significantly reduces the training time, but also achieves higher denoising performance and maintains approximate performance of blob identification compared with training on the entire dataset.
- 28 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (15) , 7599
Open AccessGAN Training Acceleration Using Fréchet Descriptor-Based Coreset
Generative Adversarial Networks (GANs) are a class of deep learning models being applied to image processing. GANs have demonstrated state-of-the-art performance in applications such as image generation and image-to-image translation, just to name a few. However, with this success comes the realization that the training of GANs takes a long time and is often limited by available computing resources. In this research, we propose to construct a Coreset using Fréchet Descriptor Distances (FDD-Coreset) to accelerate the training of GAN for blob identification. We first propose a Fréchet Descriptor Distance (FDD) to measure the difference between each pair of blob images based on the statistics derived from blob distribution. The Coreset is then employed using our proposed FDD metric to select samples from the entire dataset for GAN training. A 3D-simulated dataset of blobs and a 3D MRI dataset of human kidneys are studied. Using computation time and eight performance metrics, the GAN trained on the FDD-Coreset is compared against the model trained on the entire dataset and an Inception and Euclidean Distance-based Coreset (IED-Coreset). We conclude that the FDD-Coreset not only significantly reduces the training time, but also achieves higher denoising performance and maintains approximate performance of blob identification compared with training on the entire dataset.
- 23 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (9) , 2654-2665
Small Blob Detector Using Bi-Threshold Constrained Adaptive Scales
Recent advances in medical imaging technology bring great promises for medicine practices. Imaging biomarkers are discovered to inform disease diagnosis, prognosis, and treatment assessment. Detecting and segmenting objects from images are often the first steps in quantitative measurement of these biomarkers. The challenges of detecting objects in images, particularly small objects known as blobs, include low image resolution, image noise and overlap among the blobs. This research proposes a Bi-Threshold Constrained Adaptive Scale (BTCAS) blob detector to uncover the relationship between the U-Net threshold and the Difference of Gaussian (DoG) scale to derive a multi-threshold, multi-scale small blob detector. With lower and upper bounds on the probability thresholds from U-Net, two binarized maps of the distance are rendered between blob centers. Each blob is transformed to a DoG space with an adaptively identified local optimum scale. A Hessian convexity map is rendered using the adaptive scale, and the under-segmentation typical of the U-Net is resolved. To validate the performance of the proposed BTCAS, a 3D simulated dataset (n = 20) of blobs, a 3D MRI dataset of human kidneys and a 3D MRI dataset of mouse kidneys, are studied. BTCAS is compared against four state-of-the-art methods: HDoG, U-Net with standard thresholding, U-Net with optimal thresholding, and UH-DoG using precision, recall, F-score, Dice and IoU. We conclude that BTCAS statistically outperforms the compared detectors.
- 23 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (9) , 2654-2665
Small Blob Detector Using Bi-Threshold Constrained Adaptive Scales
Recent advances in medical imaging technology bring great promises for medicine practices. Imaging biomarkers are discovered to inform disease diagnosis, prognosis, and treatment assessment. Detecting and segmenting objects from images are often the first steps in quantitative measurement of these biomarkers. The challenges of detecting objects in images, particularly small objects known as blobs, include low image resolution, image noise and overlap among the blobs. This research proposes a Bi-Threshold Constrained Adaptive Scale (BTCAS) blob detector to uncover the relationship between the U-Net threshold and the Difference of Gaussian (DoG) scale to derive a multi-threshold, multi-scale small blob detector. With lower and upper bounds on the probability thresholds from U-Net, two binarized maps of the distance are rendered between blob centers. Each blob is transformed to a DoG space with an adaptively identified local optimum scale. A Hessian convexity map is rendered using the adaptive scale, and the under-segmentation typical of the U-Net is resolved. To validate the performance of the proposed BTCAS, a 3D simulated dataset (n = 20) of blobs, a 3D MRI dataset of human kidneys and a 3D MRI dataset of mouse kidneys, are studied. BTCAS is compared against four state-of-the-art methods: HDoG, U-Net with standard thresholding, U-Net with optimal thresholding, and UH-DoG using precision, recall, F-score, Dice and IoU. We conclude that BTCAS statistically outperforms the compared detectors.
- 8 September 2020
- Published by Elsevier in Kidney International
- Vol. 99 (1) , 173-185
Magnetic resonance imaging accurately tracks kidney pathology and heterogeneity in the transition from acute kidney injury to chronic kidney disease
- 8 September 2020
- Published by Elsevier in Kidney International
- Vol. 99 (1) , 173-185
Magnetic resonance imaging accurately tracks kidney pathology and heterogeneity in the transition from acute kidney injury to chronic kidney disease
- Open Access
AD-NET: Age-adjust neural network for improved MCI to AD conversion prediction
A bstract: The prediction of Mild Cognitive Impairment (MCI) patients who are at higher risk converting to Alzheimer’s Disease (AD) is critical for effective intervention and patient selection in clinical trials. Different biomarkers including neuroimaging have been developed to serve the purpose. With extensive methodology development efforts on neuroimaging, an emerging field is deep learning research. One great challenge facing deep learning is the limited medical imaging data available. To address the issue, researchers explore the use of transfer learning to extend the applicability of deep models on neuroimaging research for AD diagnosis and prognosis. Existing transfer learning models mostly focus on transferring the features from the pre-training into the fine-tuning stage. Recognizing the advantages of the knowledge gained during the pre-training, we propose an AD-NET (Age-adjust neural network) with the pre-training model serving two purposes: extracting and transferring features; and obtaining and transferring knowledge. Specifically, the knowledge being transferred in this research is an age-related surrogate biomarker. To evaluate the effectiveness of the proposed approach, AD-NET is compared with 8 classification models from literature using the same public neuroimaging dataset. Experimental results show that the proposed AD-NET outperforms the competing models in predicting the MCI patients at risk for conversion to the AD stage.
Open AccessAD-NET: Age-adjust neural network for improved MCI to AD conversion prediction
A bstract: The prediction of Mild Cognitive Impairment (MCI) patients who are at higher risk converting to Alzheimer’s Disease (AD) is critical for effective intervention and patient selection in clinical trials. Different biomarkers including neuroimaging have been developed to serve the purpose. With extensive methodology development efforts on neuroimaging, an emerging field is deep learning research. One great challenge facing deep learning is the limited medical imaging data available. To address the issue, researchers explore the use of transfer learning to extend the applicability of deep models on neuroimaging research for AD diagnosis and prognosis. Existing transfer learning models mostly focus on transferring the features from the pre-training into the fine-tuning stage. Recognizing the advantages of the knowledge gained during the pre-training, we propose an AD-NET (Age-adjust neural network) with the pre-training model serving two purposes: extracting and transferring features; and obtaining and transferring knowledge. Specifically, the knowledge being transferred in this research is an age-related surrogate biomarker. To evaluate the effectiveness of the proposed approach, AD-NET is compared with 8 classification models from literature using the same public neuroimaging dataset. Experimental results show that the proposed AD-NET outperforms the competing models in predicting the MCI patients at risk for conversion to the AD stage.
- Open Access
- 15 January 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-12
Improved small blob detection in 3D images using jointly constrained deep learning and Hessian analysis
Imaging biomarkers are being rapidly developed for early diagnosis and staging of disease. The development of these biomarkers requires advances in both image acquisition and analysis. Detecting and segmenting objects from images are often the first steps in quantitative measurement of these biomarkers. The challenges of detecting objects in images, particularly small objects known as blobs, include low image resolution, image noise and overlap between the blobs. The Difference of Gaussian (DoG) detector has been used to overcome these challenges in blob detection. However, the DoG detector is susceptible to over-detection and must be refined for robust, reproducible detection in a wide range of medical images. In this research, we propose a joint constraint blob detector from U-Net, a deep learning model, and Hessian analysis, to overcome these problems and identify true blobs from noisy medical images. We evaluate this approach, UH-DoG, using a public 2D fluorescent dataset for cell nucleus detection and a 3D kidney magnetic resonance imaging dataset for glomerulus detection. We then compare this approach to methods in the literature. While comparable to the other four comparing methods on recall, the UH-DoG outperforms them on both precision and F-score.
- 15 January 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-12
Open AccessImproved small blob detection in 3D images using jointly constrained deep learning and Hessian analysis
Imaging biomarkers are being rapidly developed for early diagnosis and staging of disease. The development of these biomarkers requires advances in both image acquisition and analysis. Detecting and segmenting objects from images are often the first steps in quantitative measurement of these biomarkers. The challenges of detecting objects in images, particularly small objects known as blobs, include low image resolution, image noise and overlap between the blobs. The Difference of Gaussian (DoG) detector has been used to overcome these challenges in blob detection. However, the DoG detector is susceptible to over-detection and must be refined for robust, reproducible detection in a wide range of medical images. In this research, we propose a joint constraint blob detector from U-Net, a deep learning model, and Hessian analysis, to overcome these problems and identify true blobs from noisy medical images. We evaluate this approach, UH-DoG, using a public 2D fluorescent dataset for cell nucleus detection and a 3D kidney magnetic resonance imaging dataset for glomerulus detection. We then compare this approach to methods in the literature. While comparable to the other four comparing methods on recall, the UH-DoG outperforms them on both precision and F-score.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1761-1767
U-Net with optimal thresholding for small blob detection in medical images
Biomarkers identified from medical images are valuable for disease diagnosis and staging. Object detection and segmentation are important for improving the accuracy of biomarker identification. It can be challenging to detect objects, especially small objects or “blobs,” from 3D images secondary to low image resolution, noise, and overlap. Traditional small blob filters generate significant false positives as noise components can be misidentified as regions of interest. Recent advancements in U-Net–a deep learning model–have yielded more effective denoising capabilities that make it more suitable for small blob detection. However, unless the intensity threshold is appropriately established, U-Net tends to “under-segment To address under-segmentation, we propose a combination of U-Net paired with optimal threshold detection via Otsu’s thresholding. Two sets of experiments have been performed to compare this approach with both Hessian-based blob detection and U-Net with standard thresholding. The first experiment evaluated 20 simulated 3D images–comprising gloms with a varied size distribution, and noise. The second experiment examined MR images from 11 mouse kidneys with the objective of detecting all glomeruli. Our results support the conclusion that the proposed U-Net with optimal thresholding outperforms the Hessian-based detection and U-Net with standard thresholding approaches.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1761-1767
U-Net with optimal thresholding for small blob detection in medical images
Biomarkers identified from medical images are valuable for disease diagnosis and staging. Object detection and segmentation are important for improving the accuracy of biomarker identification. It can be challenging to detect objects, especially small objects or “blobs,” from 3D images secondary to low image resolution, noise, and overlap. Traditional small blob filters generate significant false positives as noise components can be misidentified as regions of interest. Recent advancements in U-Net–a deep learning model–have yielded more effective denoising capabilities that make it more suitable for small blob detection. However, unless the intensity threshold is appropriately established, U-Net tends to “under-segment To address under-segmentation, we propose a combination of U-Net paired with optimal threshold detection via Otsu’s thresholding. Two sets of experiments have been performed to compare this approach with both Hessian-based blob detection and U-Net with standard thresholding. The first experiment evaluated 20 simulated 3D images–comprising gloms with a varied size distribution, and noise. The second experiment examined MR images from 11 mouse kidneys with the objective of detecting all glomeruli. Our results support the conclusion that the proposed U-Net with optimal thresholding outperforms the Hessian-based detection and U-Net with standard thresholding approaches.
- Open Access
- 11 July 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Integration of machine learning and mechanistic models accurately predicts variation in cell density of glioblastoma using multiparametric MRI
Glioblastoma (GBM) is a heterogeneous and lethal brain cancer. These tumors are followed using magnetic resonance imaging (MRI), which is unable to precisely identify tumor cell invasion, impairing effective surgery and radiation planning. We present a novel hybrid model, based on multiparametric intensities, which combines machine learning (ML) with a mechanistic model of tumor growth to provide spatially resolved tumor cell density predictions. The ML component is an imaging data-driven graph-based semi-supervised learning model and we use the Proliferation-Invasion (PI) mechanistic tumor growth model. We thus refer to the hybrid model as the ML-PI model. The hybrid model was trained using 82 image-localized biopsies from 18 primary GBM patients with pre-operative MRI using a leave-one-patient-out cross validation framework. A Relief algorithm was developed to quantify relative contributions from the data sources. The ML-PI model statistically significantly outperformed (p < 0.001) both individual models, ML and PI, achieving a mean absolute predicted error (MAPE) of 0.106 ± 0.125 versus 0.199 ± 0.186 (ML) and 0.227 ± 0.215 (PI), respectively. Associated Pearson correlation coefficients for ML-PI, ML, and PI were 0.838, 0.518, and 0.437, respectively. The Relief algorithm showed the PI model had the greatest contribution to the result, emphasizing the importance of the hybrid model in achieving the high accuracy.
- 11 July 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Open AccessIntegration of machine learning and mechanistic models accurately predicts variation in cell density of glioblastoma using multiparametric MRI
Glioblastoma (GBM) is a heterogeneous and lethal brain cancer. These tumors are followed using magnetic resonance imaging (MRI), which is unable to precisely identify tumor cell invasion, impairing effective surgery and radiation planning. We present a novel hybrid model, based on multiparametric intensities, which combines machine learning (ML) with a mechanistic model of tumor growth to provide spatially resolved tumor cell density predictions. The ML component is an imaging data-driven graph-based semi-supervised learning model and we use the Proliferation-Invasion (PI) mechanistic tumor growth model. We thus refer to the hybrid model as the ML-PI model. The hybrid model was trained using 82 image-localized biopsies from 18 primary GBM patients with pre-operative MRI using a leave-one-patient-out cross validation framework. A Relief algorithm was developed to quantify relative contributions from the data sources. The ML-PI model statistically significantly outperformed (p < 0.001) both individual models, ML and PI, achieving a mean absolute predicted error (MAPE) of 0.106 ± 0.125 versus 0.199 ± 0.186 (ML) and 0.227 ± 0.215 (PI), respectively. Associated Pearson correlation coefficients for ML-PI, ML, and PI were 0.838, 0.518, and 0.437, respectively. The Relief algorithm showed the PI model had the greatest contribution to the result, emphasizing the importance of the hybrid model in achieving the high accuracy.
- 22 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (1) , 39-49
Deep Residual Inception Encoder–Decoder Network for Medical Imaging Synthesis
Image synthesis is a novel solution in precision medicine for scenarios where important medical imaging is not otherwise available. Convolutional neural network is an ideal model for this task because of its powerful learning capabilities through the large number of layers and trainable parameters. In this research, we propose a new architecture of Residual Inception Encoder-Decoder Neural Network (RIED-Net) to learn the nonlinear mapping between the input images and targeting output images. To evaluate the validity of the proposed approach, it is compared with 2 models from the literature: sCT-DCNN and Shallow CNN, using both an institutional mammogram dataset from Mayo Clinic Arizona and a public neuroimaging dataset from the Alzheimer's Disease Neuroimaging Initiative (ADNI). Experimental results show that the proposed RIED-Net outperforms the two models on both datasets significantly in terms of structural similarity index (SSIM), mean absolute percent error (MAPE), and peak signal to noise ratio (PSNR).
- 22 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (1) , 39-49
Deep Residual Inception Encoder–Decoder Network for Medical Imaging Synthesis
Image synthesis is a novel solution in precision medicine for scenarios where important medical imaging is not otherwise available. Convolutional neural network is an ideal model for this task because of its powerful learning capabilities through the large number of layers and trainable parameters. In this research, we propose a new architecture of Residual Inception Encoder-Decoder Neural Network (RIED-Net) to learn the nonlinear mapping between the input images and targeting output images. To evaluate the validity of the proposed approach, it is compared with 2 models from the literature: sCT-DCNN and Shallow CNN, using both an institutional mammogram dataset from Mayo Clinic Arizona and a public neuroimaging dataset from the Alzheimer's Disease Neuroimaging Initiative (ADNI). Experimental results show that the proposed RIED-Net outperforms the two models on both datasets significantly in terms of structural similarity index (SSIM), mean absolute percent error (MAPE), and peak signal to noise ratio (PSNR).
- Open Access
- 28 February 2019
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (3) , 418-425
Accurate Patient-Specific Machine Learning Models of Glioblastoma Invasion Using Transfer Learning
BACKGROUND AND PURPOSE: MR imaging–based modeling of tumor cell density can substantially improve targeted treatment of glioblastoma. Unfortunately, interpatient variability limits the predictive ability of many modeling approaches. We present a transfer learning method that generates individualized patient models, grounded in the wealth of population data, while also detecting and adjusting for interpatient variabilities based on each patient9s own histologic data. MATERIALS AND METHODS: We recruited patients with primary glioblastoma undergoing image-guided biopsies and preoperative imaging, including contrast-enhanced MR imaging, dynamic susceptibility contrast MR imaging, and diffusion tensor imaging. We calculated relative cerebral blood volume from DSC-MR imaging and mean diffusivity and fractional anisotropy from DTI. Following image coregistration, we assessed tumor cell density for each biopsy and identified corresponding localized MR imaging measurements. We then explored a range of univariate and multivariate predictive models of tumor cell density based on MR imaging measurements in a generalized one-model-fits-all approach. We then implemented both univariate and multivariate individualized transfer learning predictive models, which harness the available population-level data but allow individual variability in their predictions. Finally, we compared Pearson correlation coefficients and mean absolute error between the individualized transfer learning and generalized one-model-fits-all models. RESULTS: Tumor cell density significantly correlated with relative CBV (r = 0.33, P < .001), and T1-weighted postcontrast (r = 0.36, P < .001) on univariate analysis after correcting for multiple comparisons. With single-variable modeling (using relative CBV), transfer learning increased predictive performance (r = 0.53, mean absolute error = 15.19%) compared with one-model-fits-all (r = 0.27, mean absolute error = 17.79%). With multivariate modeling, transfer learning further improved performance (r = 0.88, mean absolute error = 5.66%) compared with one-model-fits-all (r = 0.39, mean absolute error = 16.55%). CONCLUSIONS: Transfer learning significantly improves predictive modeling performance for quantifying tumor cell density in glioblastoma.
- 28 February 2019
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (3) , 418-425
Open AccessAccurate Patient-Specific Machine Learning Models of Glioblastoma Invasion Using Transfer Learning
BACKGROUND AND PURPOSE: MR imaging–based modeling of tumor cell density can substantially improve targeted treatment of glioblastoma. Unfortunately, interpatient variability limits the predictive ability of many modeling approaches. We present a transfer learning method that generates individualized patient models, grounded in the wealth of population data, while also detecting and adjusting for interpatient variabilities based on each patient9s own histologic data. MATERIALS AND METHODS: We recruited patients with primary glioblastoma undergoing image-guided biopsies and preoperative imaging, including contrast-enhanced MR imaging, dynamic susceptibility contrast MR imaging, and diffusion tensor imaging. We calculated relative cerebral blood volume from DSC-MR imaging and mean diffusivity and fractional anisotropy from DTI. Following image coregistration, we assessed tumor cell density for each biopsy and identified corresponding localized MR imaging measurements. We then explored a range of univariate and multivariate predictive models of tumor cell density based on MR imaging measurements in a generalized one-model-fits-all approach. We then implemented both univariate and multivariate individualized transfer learning predictive models, which harness the available population-level data but allow individual variability in their predictions. Finally, we compared Pearson correlation coefficients and mean absolute error between the individualized transfer learning and generalized one-model-fits-all models. RESULTS: Tumor cell density significantly correlated with relative CBV (r = 0.33, P < .001), and T1-weighted postcontrast (r = 0.36, P < .001) on univariate analysis after correcting for multiple comparisons. With single-variable modeling (using relative CBV), transfer learning increased predictive performance (r = 0.53, mean absolute error = 15.19%) compared with one-model-fits-all (r = 0.27, mean absolute error = 17.79%). With multivariate modeling, transfer learning further improved performance (r = 0.88, mean absolute error = 5.66%) compared with one-model-fits-all (r = 0.39, mean absolute error = 16.55%). CONCLUSIONS: Transfer learning significantly improves predictive modeling performance for quantifying tumor cell density in glioblastoma.