The Failure Index as marker of cochlear health in MED-EL CI users: Anatomy, demographics, and speech correlations
Preprint
Abstract
Cochlear implants (CIs) enable hearing with the deafened ear, via direct, electrical stimulation of the spiral ganglion neurons (SGN). Thus, the outcome depends on the number and excitability of the SGNs. We recently established the electrically-evoked compound action potential (eCAP)-derived Failure Index (FI) as cochlear-health marker in the animal model. The FI informs about the presence, site, and size of a SGN lesion. Here, we translated the FI to clinical recordings of MED-EL CI users. For the retrospective study, we selected patient data from the database of the German Hearing Center Hannover recorded 2017 to 2024. We included 199 post-lingually and 79 pre-lingually deafened ears. Averaged FIs over all contacts of a CI were stable within the analysis period (3 rd month to 1 st year postoperatively). The FI increased with age and was elevated for etiologies associated with higher SGN loss. Utilizing 3D information from cone beam-computed tomography scans, we confirmed that the FI was independent of distance (0.1-2.5 mm) to the modiolus. The FI showed individual patterns along the array with maxima usually at basal contacts, corresponding to elevated SGN loss at high frequencies. In a selected group of post-lingually deaf ears, we confirmed the correlation of the FI with speech perception in quiet and in noise (n=28, r 2 =0.12-0.55). Thus, we propose the FI as promising clinical tool to identify CI-implanted ears with reduced neural health and contacts close to areas of SGN loss. Thereby, it can serve to guide speech-processor fitting to optimize CI outcomes.Keywords
This publication has 53 references indexed in Scilit:
- Contributions of Auditory Nerve Density and Synchrony to Speech Understanding in Older Cochlear Implant UsersJournal of the Association for Research in Otolaryngology, 2025
- Comparing Patient-Specific Variations in Intra-Cochlear Neural Health Estimated Using Psychophysical Thresholds and Panoramic Electrically Evoked Compound Action Potentials (PECAPs)Journal of the Association for Research in Otolaryngology, 2025
- Cochlear Health and Cochlear-implant FunctionJournal of the Association for Research in Otolaryngology, 2023
- Cochlear Implant Research and Development in the Twenty-first Century: A Critical UpdateJournal of the Association for Research in Otolaryngology, 2021
- Association of Patient-Related Factors With Adult Cochlear Implant Speech Recognition OutcomesJAMA Otolaryngology–Head & Neck Surgery, 2020
- Polarity Sensitivity as a Potential Correlate of Neural Degeneration in Cochlear Implant UsersJournal of the Association for Research in Otolaryngology, 2020
- Assessing the Electrode-Neuron Interface with the Electrically Evoked Compound Action Potential, Electrode Position, and Behavioral ThresholdsJournal of the Association for Research in Otolaryngology, 2016
- Cochlear length determination using Cone Beam Computed Tomography in a clinical settingHearing Research, 2014
- Examining the Electro-Neural Interface of Cochlear Implant Users Using Psychophysics, CT Scans, and Speech UnderstandingJournal of the Association for Research in Otolaryngology, 2014
- Über Sprachaudiometrie und neue Wörterteste1953