Comparing Patient-Specific Variations in Intra-Cochlear Neural Health Estimated Using Psychophysical Thresholds and Panoramic Electrically Evoked Compound Action Potentials (PECAPs)
Authors:
- 8 January 2025
- journal article
- research article
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 26 (1) , 77-91
Abstract
Purpose Variations in neural survival along the cochlear implant electrode array leads to off-place listening, resulting in poorer speech understanding outcomes for recipients. Therefore, it is important to develop and compare clinically viable tests to identify these patient-specific intra-cochlear neural differences. Methods Nineteen experienced cochlear implant recipients (9 males and 10 females) were recruited for this study. We estimated the neural health along the electrode array for a group of experienced adult implant recipients using two methods: the difference between psychophysical detection thresholds in bipolar vs. monopolar mode and the panoramic electrically evoked compound action potential method (PECAP). We hypothesised that: neural health estimated using both methods at single electrodes will be correlated at the participant level and the group level; and participants with larger variations in neural health along the electrode array will have poorer speech outcomes. Results At the individual level, the two neural measures correlated significantly across electrodes (p < 0.05) for 5 out of 15 participants. At the group level, we observed a weak but significant across-electrode correlation (R2 = 0.111, p < 0.001). While a larger variation in neural measures estimated from psychophysical thresholds was associated with lower phoneme speech scores (R2 = 0.499, p < 0.01), no significant association was found between variations in PECAP’s neural health estimates and phoneme speech scores (R2 = 0.082, p = 0.366). Conclusion Our evidence suggests that both methods likely quantify a shared underlying neural basis, hypothesised to be the neural health along the cochlear implant array. The differences between the two measures may be attributed to differences in stimulus rate or loudness used to elicit responses and/or the influence of factors arising more centrally than the auditory nerve.Keywords
All Related Versions
Funding Information
- Garnett Passe and Rodney Williams Memorial Foundation (Junior Fellowship, Conjoint Grant)
- Wellcome Trust (RG91976)
This publication has 23 references indexed in Scilit:
- Within-Subject Comparison of Word Recognition and Spiral Ganglion Cell Count in Bilateral Cochlear Implant RecipientsOtology & Neurotology, 2014
- Examining the Electro-Neural Interface of Cochlear Implant Users Using Psychophysics, CT Scans, and Speech UnderstandingJournal of the Association for Research in Otolaryngology, 2014
- Auditory-Nerve Responses to Varied Inter-Phase Gap and Phase Duration of the Electric Pulse Stimulus as Predictors for Neuronal DegenerationJournal of the Association for Research in Otolaryngology, 2014
- Threshold and channel interaction in cochlear implant users: Evaluation of the tripolar electrode configurationThe Journal of the Acoustical Society of America, 2007
- Relationships among Speech Perception, Self-Rated Tinnitus Loudness and Disability in Tinnitus Patients with Normal Pure-Tone Thresholds of HearingORL, 2006
- Across-Site Variation in Detection Thresholds and Maximum Comfortable Loudness Levels for Cochlear ImplantsJournal of the Association for Research in Otolaryngology, 2004
- Summary of Results Using the Nucleus CI24M Implant to Record the Electrically Evoked Compound Action PotentialEar & Hearing, 1999
- Loudness perception with pulsatile electrical stimulation: The effect of interpulse intervalsThe Journal of the Acoustical Society of America, 1998
- Electrically evoked whole-nerve action potentials: Data from human cochlear implant usersThe Journal of the Acoustical Society of America, 1990
- A "Rationalized" Arcsine TransformJournal of Speech, Language, and Hearing Research, 1985