Determination of Platelet Estimate Factor of Sysmex DI-60 Digital Morphology Analyzer for Platelet Count Estimation
Open Access
- 7 December 2023
- journal article
- research article
- Published by Archives of Pathology and Laboratory Medicine in Archives of Pathology & Laboratory Medicine
- Vol. 148 (9) , 1046-1051
Abstract
Context.—: In the Sysmex DI-60 digital morphology system, a platelet estimate factor (PEF) is used to calculate the estimated platelet count (PLT). Objective.—: To determine the most accurate PEF by analyzing various specimens, including those with abnormal flag alerts, using both impedance (PLT-I) and optical fluorescent (PLT-F) PLT methods. A validation study was then conducted using random specimens to evaluate the accuracy of the PEF. Design.—: This study included 120 blood specimens without flag alerts, and 120 blood specimens with flag alerts related to platelet abnormalities to determine the PEF. Each group was equally divided into thrombocytopenia, normal count, and thrombocytosis specimens. The PEF values obtained from the PLT-I and PLT-F methods were analyzed. An additional 120 specimens were used to compare the estimated PLT from PEF with the PLT-F count. Unadjusted PEF disregarded platelet ranges and flag alerts, whereas adjusted PEF incorporated them. Results.—: The mean PEF values ranged within 9.95 to 12.99 for PLT-I–obtained values (PEF-I) and within 10.32 to 11.69 for PLT-F–obtained values (PEF-F) across different PLT ranges. The mean PEF values were significantly higher in specimens with flags compared with those without flags. The values were 12.43 compared with 10.19 for PEF-I and 11.45 compared with 10.4 for PEF-F. A significant difference was found between PEF-I and PEF-F in flagged specimens, with respective values of 12.43 and 11.45. There was excellent agreement between estimated PLTs using adjusted PEF and PLT-F. However, proportional biases were observed between estimated PLT using unadjusted PEF and PLT-F. Conclusions.—: Adjustment of PEF values according to specific platelet ranges and flag alert presence was shown to enhance the accuracy of PLT estimation using the Sysmex DI-60 system.Keywords
This publication has 9 references indexed in Scilit:
- Red and white blood cell morphology characterization and hands-on time analysis by the digital cell imaging analyzer DI-60PLOS ONE, 2022
- Clinical and laboratory diagnosis of heritable platelet disorders in adults and children: a British Society for Haematology GuidelineBritish Journal of Haematology, 2021
- Compare the accuracy and precision of Coulter LH780, Mindray BC-6000 Plus, and Sysmex XN-9000 with the international reference flow cytometric method in platelet countingPLOS ONE, 2019
- Digital morphology analyzers in hematology: ICSH review and recommendationsInternational Journal of Laboratory Hematology, 2019
- Analytical performance of automated platelet counts and impact on platelet transfusion guidance in patients with acute leukemiaScandinavian Journal of Clinical and Laboratory Investigation, 2019
- Essential thrombocythemia treatment algorithm 2018Blood Cancer Journal, 2018
- Performance of automated digital cell imaging analyzer Sysmex DI-60Clinical Chemistry and Laboratory Medicine (CCLM), 2017
- Accuracy of a New Platelet Count System (PLT-F) Depends on the Staining Property of Its ReagentsPLOS ONE, 2015
- Performance evaluation of the digital cell imaging analyzer DI-60 integrated into the fully automated Sysmex XN hematology analyzer systemClinical Chemistry and Laboratory Medicine (CCLM), 2015