Mechanical analysis of percutaneous sacroplasty using CT image based finite element models
- 24 May 2006
- journal article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 29 (3) , 316-325
Abstract
Sacral insufficiency fractures are an under-diagnosed source of acute lower back pain. A polymethylmethacrylate (PMMA) cement injection procedure called sacroplasty has recently been utilized as a treatment for sacral insufficiency fractures. It is believed that injection of cement reduces fracture micromotion, thus relieving pain. In this study, finite element models were used to examine the mechanical effects of sacroplasty. Finite element models were constructed from CT images of two cadavers on which sacroplasties were performed. The images were used to create the mesh geometry, and to apply non-homogeneous material properties to the models. Models were created representing the case with and without cement, thus simulating the pre- and post-sacroplasty situation. The results indicate that the sacrum has a 3D multi-axial state of strain. While compressive strains were the largest, tensile and shear strains were significant as well. Cement in the sacrum reduced strains 40-60% locally around the cement. However, overall model stiffness only increased 1-4%. This indicates that the effects of sacroplasty are primarily local.Keywords
This publication has 32 references indexed in Scilit:
- Vertebroplasty and Kyphoplasty Affect Vertebral Motion Segment Stiffness and Stress DistributionsSpine, 2005
- Augmentation of mechanical properties in osteoporotic vertebral bones – a biomechanical investigation of vertebroplasty efficacy with different bone cementsEuropean Spine Journal, 2001
- Percutaneous cementoplasty for pelvic bone metastasisSupportive Care in Cancer, 2000
- The Controversy Surrounding Sacral Insufficiency FracturesAmerican Journal of Physical Medicine & Rehabilitation, 2000
- Three-Dimensional Finite Element Analysis of Several Internal and External Pelvis FixationsJournal of Biomechanical Engineering, 2000
- Internal Fixation for the Transforaminal Sacral FractureClinical Orthopaedics and Related Research, 1996
- Insufficiency Fractures of the SacrumSpine, 1993
- Mechanical Properties of Bone CementClinical Orthopaedics and Related Research, 1991
- Computer aided stress analysis of long bones utilizing computed tomographyJournal of Biomechanics, 1990
- The mechanical properties of trabecular bone: Dependence on anatomic location and functionJournal of Biomechanics, 1987