Surface Engineering of Poly(ethylene terephthalate) for Durable Hemocompatibility via a Surface Interpenetrating Network Technique
- 7 September 2012
- journal article
- research article
- Published by Wiley in Macromolecular Chemistry and Physics
- Vol. 213 (20) , 2120-2129
Abstract
Heparin was covalently bonded on chemically inert PET substrate using a surface modification technique–surface interpenetrating network with the purpose of fabricating long‐lasting biocompatible materials as vascular grafts. FTIR and XPS spectra confirmed the successful heparinization of PET (PET‐Hep). The density of surface‐immobilized heparin as quantified by a colorimetric method could reach 2.4 μg cm−2 (in the reported optimal range: 1.5–3.0 μg cm−2). The hemocompatibility of the heparin‐immobilized PET was improved as evidenced by a platelet adhesion test: significantly less platelet adhesion on PET‐Hep (11.60%) than on untreated PET (48.91%). An MTT assay indicated PET‐Hep was nontoxic to human dermal fibroblast cells. After an initial 5.24% loss of heparin from PET‐Hep in the first 14 h immersion in PBS buffer solution, no further leaching of heparin was found.Keywords
This publication has 44 references indexed in Scilit:
- In Vitro Haemocompatibility Evaluation of PET Surfaces Using the Quartz Crystal Microbalance TechniqueJournal of Biomaterials Science, Polymer Edition, 2012
- Heart Disease and Stroke Statistics—2011 UpdateCirculation, 2011
- Imidazole/Poly(Ethylene Glycol)-Substituted Poly(N-(8-Aminooctyl)Acrylamide) as Biocompatible and Efficient Gene CarrierJournal of Biomaterials Science, Polymer Edition, 2011
- Measurement of Protein−Ligand Binding Constants from Reaction-Diffusion Concentration ProfilesAnalytical Chemistry, 2010
- Biocompatibility and antibacterial activity of chitosan and hyaluronic acid immobilized polyester fibersJournal of Applied Polymer Science, 2007
- Modulation of Angiogenic Potential of Collagen Matrices by Covalent Incorporation of Heparin and Loading with Vascular Endothelial Growth FactorTissue Engineering, 2004
- Comparison of outcomes up to six months of Heparin-Coated with noncoated stents after percutaneous coronary intervention for acute myocardial infarctionThe American Journal of Cardiology, 2004
- Thermoresponsive Heparin Coating: Heparin Conjugated with Poly(N-isopropylacrylamide) at One TerminusLangmuir, 2002
- Surface modification of the biomedical polymer poly(ethylene terephthalate)The Analyst, 1993
- Physical properties of polyester fibers degraded by aminolysis and by alkalin hydrolysisJournal of Applied Polymer Science, 1982