Supplement 2 for the 2004 update of theAAPMTask Group No. 43 Report: Joint recommendations by theAAPMandGEC‐ESTRO

Authors:

Abstract
Since the publication of the 2004 update to the American Association of Physicists in Medicine (AAPM) Task Group No. 43 Report (TG‐43U1) and its 2007 supplement (TG‐43U1S1), several new low‐energy photon‐emitting brachytherapy sources have become available. Many of these sources have satisfied theAAPMprerequisites for routine clinical purposes and are posted on the Brachytherapy Source Registry managed jointly by theAAPMand the Imaging and Radiation Oncology Core Houston Quality Assurance Center (IROCHouston). Given increasingly closer interactions among physicists in North America and Europe, theAAPMand the Groupe Européen de Curiethérapie‐European Society for Radiotherapy & Oncology (GEC‐ESTRO) have prepared another supplement containing recommended brachytherapy dosimetry parameters for eleven low‐energy photon‐emitting brachytherapy sources. The current report presents consensus datasets approved by theAAPMandGEC‐ESTRO. The following sources are included:125I sources (BEBIGmodel I25.S17,BEBIGmodel I25.S17plus,BEBIGmodel I25.S18, Elekta model 130.002, Oncura model 9011, and Theragenics model AgX100);103Pd sources (CivaTech Oncology modelCS10,IBt model 1031L,IBt model 1032P, and IsoAid modelIAPd‐103A); and131Cs (IsoRay Medical modelCS‐1 Rev2). Observations are included on the behavior of these dosimetry parameters as a function of radionuclide.Recommendations are presented on the selection of dosimetry parameters, such as from societal reports issuing consensus datasets (e.g.,TG‐43U1,AAPMReport #229), the jointAAPM/IROCHouston Registry, theGEC‐ESTROwebsite, the Carleton University website, and those included in software releases from vendors of treatment planning systems. Aspects such as timeliness, maintenance, and rigor of these resources are discussed.Links to reference data are provided for radionuclides (radiation spectra and half‐lives) and dose scoring materials (compositions and mass densities). The recent literature is examined on photon energy response corrections for thermoluminescent dosimetry of low‐energy photon‐emitting brachytherapy sources. Depending upon the dosimetry parameters currently used by individual physicists, use of these recommended consensus datasets may result in changes to patient dose calculations. These changes must be carefully evaluated and reviewed with the radiation oncologist prior to their implementation.

This publication has 86 references indexed in Scilit: