Selection of Reversed-Phase C18 Separation Media for Bottom-Up Proteomics: Multifactor Comparison of Fully Porous Sorbents Including Separation Selectivity and Carryover Characteristics
- 21 April 2026
- journal article
- Published by American Chemical Society (ACS) in Journal of Proteome Research
Abstract
Seven popular C18 stationary phases for peptide separation in bottom-up proteomics have been evaluated based on overall peptide retention, column backpressure, separation selectivity and efficiency, number of peptide identifications, and carryover statistics. Under standard 0.1% formic acid water-acetonitrile elution conditions, peptide retention varies within an elution range of ∼3.4% acetonitrile and increases in the following order: XSelect CSH C18 2.5 μm, 130 Å < Luna C18(2) 3 μm, 100 Å < PepMap RSLC C18 2 μm, 100 Å ≪ Reprosil-Pur ODS-3 3 μm, 120 Å < Reprosil-Pur C18 AQ 3 μm, 120 Å < Magic C18 AQ 3 μm, 200 Å < XBridge BEH C18 2.5 μm, 130 Å. While the lower retention on the XSelect was expected due to the embedded positively charged groups, the behavior of Luna C18(2) and PepMap C18 can be explained by the reduction of surface accessibility for small pore size matrices. Pore size was a major contributor to varying separation selectivity. The number of unique peptide identifications is driven by peptide separation efficiency and retentivity. These factors favor sorbents with smaller particle sizes and higher retentivity, such as XBridge BEH C18. Low peptide retentivity and average separation efficiency diminish identification output for Luna C18(2) and PepMap RSLC with 100 Å pore size.Keywords
Funding Information
- University of Manitoba
- Common Fund (R01 GM132129)
- Common Fund (R35 GM156406)
- Natural Sciences and Engineering Research Council of Canada (RGPIN-2022-05015)
This publication has 31 references indexed in Scilit:
- Evaluating C18 stationary phases with a positively charged surface for proteomic LC-MS applications using mobile phase acidified with reduced formic acid concentrationJournal of Chromatography A, 2024
- Retention time prediction for post-translationally modified peptides: Ser, Thr, Tyr-phosphorylationJournal of Chromatography A, 2024
- Nano‐LC: An updated reviewBiomedical Chromatography, 2022
- Now, More Than Ever, Proteomics Needs Better ChromatographyCell Systems, 2016
- Peptide retention time predictionMass Spectrometry Reviews, 2016
- Strategies to reduce aspecific adsorption of peptides and proteins in liquid chromatography–mass spectrometry based bioanalyses: An overviewJournal of Chromatography A, 2014
- High‐resolution peptide separations using nano‐LC at ultra‐high pressureJournal of Separation Science, 2013
- Highly multiplexed targeted proteomics using precise control of peptide retention timeProteomics, 2012
- Effects of column length, particle size, gradient length and flow rate on peak capacity of nano-scale liquid chromatography for peptide separationsJournal of Chromatography A, 2007
- Proteomic LC–MS systems using nanoscale liquid chromatography with tandem mass spectrometryJournal of Chromatography A, 2005