Darien Yeung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Darien Yeung has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Oleg V. Krokhin
University of Manitoba
12 shared publications Victor Spicer
Manitoba Centre for Proteomics and Systems Biology, University of Manitoba, 799 JBRC, 715 McDermot Avenue, Winnipeg, Manitoba R3E 3P4, Canada
9 shared publicationsBenilde Mizero
Department of Chemistry, University of Manitoba, 360 Parker Building, Winnipeg R3T 2N2, Manitoba, Canada
3 shared publicationsYing Lao
Manitoba Centre for Proteomics and Systems Biology, University of Manitoba, 799 JBRC, 715 McDermot Avenue, Winnipeg, Manitoba R3E 3P4, Canada
3 shared publications- Chih-Hsiang Chang
Department of Molecular and Cellular BioAnalysis, Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto 606-8501, Japan
2 shared publications - Jason Scott McIndoe
Department of Chemistry, University of Victoria, Victoria, BC, Canada
2 shared publications
Latest Publications
- 21 April 2026
- Published by American Chemical Society (ACS) in Journal of Proteome Research
Selection of Reversed-Phase C18 Separation Media for Bottom-Up Proteomics: Multifactor Comparison of Fully Porous Sorbents Including Separation Selectivity and Carryover Characteristics
Seven popular C18 stationary phases for peptide separation in bottom-up proteomics have been evaluated based on overall peptide retention, column backpressure, separation selectivity and efficiency, number of peptide identifications, and carryover statistics. Under standard 0.1% formic acid water-acetonitrile elution conditions, peptide retention varies within an elution range of ∼3.4% acetonitrile and increases in the following order: XSelect CSH C18 2.5 μm, 130 Å < Luna C18(2) 3 μm, 100 Å < PepMap RSLC C18 2 μm, 100 Å ≪ Reprosil-Pur ODS-3 3 μm, 120 Å < Reprosil-Pur C18 AQ 3 μm, 120 Å < Magic C18 AQ 3 μm, 200 Å < XBridge BEH C18 2.5 μm, 130 Å. While the lower retention on the XSelect was expected due to the embedded positively charged groups, the behavior of Luna C18(2) and PepMap C18 can be explained by the reduction of surface accessibility for small pore size matrices. Pore size was a major contributor to varying separation selectivity. The number of unique peptide identifications is driven by peptide separation efficiency and retentivity. These factors favor sorbents with smaller particle sizes and higher retentivity, such as XBridge BEH C18. Low peptide retentivity and average separation efficiency diminish identification output for Luna C18(2) and PepMap RSLC with 100 Å pore size.
- 21 April 2026
- Published by American Chemical Society (ACS) in Journal of Proteome Research
Selection of Reversed-Phase C18 Separation Media for Bottom-Up Proteomics: Multifactor Comparison of Fully Porous Sorbents Including Separation Selectivity and Carryover Characteristics
Seven popular C18 stationary phases for peptide separation in bottom-up proteomics have been evaluated based on overall peptide retention, column backpressure, separation selectivity and efficiency, number of peptide identifications, and carryover statistics. Under standard 0.1% formic acid water-acetonitrile elution conditions, peptide retention varies within an elution range of ∼3.4% acetonitrile and increases in the following order: XSelect CSH C18 2.5 μm, 130 Å < Luna C18(2) 3 μm, 100 Å < PepMap RSLC C18 2 μm, 100 Å ≪ Reprosil-Pur ODS-3 3 μm, 120 Å < Reprosil-Pur C18 AQ 3 μm, 120 Å < Magic C18 AQ 3 μm, 200 Å < XBridge BEH C18 2.5 μm, 130 Å. While the lower retention on the XSelect was expected due to the embedded positively charged groups, the behavior of Luna C18(2) and PepMap C18 can be explained by the reduction of surface accessibility for small pore size matrices. Pore size was a major contributor to varying separation selectivity. The number of unique peptide identifications is driven by peptide separation efficiency and retentivity. These factors favor sorbents with smaller particle sizes and higher retentivity, such as XBridge BEH C18. Low peptide retentivity and average separation efficiency diminish identification output for Luna C18(2) and PepMap RSLC with 100 Å pore size.
- Open Access
Zero-shot retention time prediction for unseen post-translational modifications with molecular structure encodings
Mass spectrometry-based proteomics relies on accurate peptide property prediction models to enhance peptide identification and characterization, especially when dealing with peptidoforms. However, current approaches are limited in their ability to generalize to peptides with novel post-translational modifications (PTMs) due to insufficient training data. To address this challenge, we introduce MoSTERT (Molecular Structure Transformer Encoder for Retention Time prediction) and its enhanced variant, MoSTERT-2S, two transformer-based models designed for zero-shot prediction of retention times of peptides with unseen PTMs. Unlike conventional models, MoSTERT encodes peptide residues at the molecular structure level, allowing it to handle diverse PTMs. MoSTERT-2S further improves accuracy by employing a two-step strategy: first predicting the retention time of the unmodified peptide, then estimating the retention time shift induced by the PTMs. Evaluation on an external dataset demonstrates that MoSTERT-2S achieves state-of-the-art performance, reducing prediction errors compared to existing methods. Its ability to accurately predict retention times for peptides with a wide variety of PTMs not seen during training highlights its potential for advancing proteomic workflows analyzing proteoforms and protein modifications.
Open AccessZero-shot retention time prediction for unseen post-translational modifications with molecular structure encodings
Mass spectrometry-based proteomics relies on accurate peptide property prediction models to enhance peptide identification and characterization, especially when dealing with peptidoforms. However, current approaches are limited in their ability to generalize to peptides with novel post-translational modifications (PTMs) due to insufficient training data. To address this challenge, we introduce MoSTERT (Molecular Structure Transformer Encoder for Retention Time prediction) and its enhanced variant, MoSTERT-2S, two transformer-based models designed for zero-shot prediction of retention times of peptides with unseen PTMs. Unlike conventional models, MoSTERT encodes peptide residues at the molecular structure level, allowing it to handle diverse PTMs. MoSTERT-2S further improves accuracy by employing a two-step strategy: first predicting the retention time of the unmodified peptide, then estimating the retention time shift induced by the PTMs. Evaluation on an external dataset demonstrates that MoSTERT-2S achieves state-of-the-art performance, reducing prediction errors compared to existing methods. Its ability to accurately predict retention times for peptides with a wide variety of PTMs not seen during training highlights its potential for advancing proteomic workflows analyzing proteoforms and protein modifications.
- 7 September 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1736, 465355
Peptide retention time prediction for hydrophilic interaction liquid chromatography at acidic pH in formic-acid based eluents
- 7 September 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1736, 465355
Peptide retention time prediction for hydrophilic interaction liquid chromatography at acidic pH in formic-acid based eluents
- 29 May 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (23) , 9721-9728
Paradigm Shift: Major Role of Ion-Pairing-Dependent Size Exclusion Effects in Bottom-Up Proteomics Reversed-Phase Peptide Separations
Can reversed-phase peptide retention be the same for C8 and C18 columns? or increase for otherwise identical columns with a smaller surface area? Can replacing trifluoroacetic acid (TFA) with formic acid (FA) improve the peak shape? According to our common understanding of peptide chromatography, absolutely not. Surprisingly, a thorough comparison of the peptide separation selectivity of 100 and 120 angstrom fully porous C18 sorbents to maximize the performance of our in-house proteomics LC-MS/MS setup revealed an unexpectedly higher peptide retentivity for a wider pore packing material, despite it having a smaller surface area. Concurrently, the observed increase in peptide retention-which drives variation in separation selectivity between 100 and 120 angstrom pore size materials-was more pronounced for smaller peptides. These findings contradict the central dogmas that underlie the development of all peptide RP-HPLC applications: (i) a larger surface area leads to higher retention and (ii) increasing the pore size should benefit the retention of larger analytes. Based on our intriguing findings, we compared reversed-phase high-performance liquid chromatography peptide retention for a total of 20 columns with pore sizes between 60 and 300 angstrom using FA- and TFA-based eluents. Our results unequivocally attest that the larger size of ion pairs in FA- vs TFA-based eluents leads to the observed impact on selectivity and peptide retention. For FA, peptide retention peaks at 200 angstrom pore size, compared to between 120 and 200 angstrom for TFA. However, the decrease in retention for narrow-pore particles is more profound in FA. Our findings suggest that common assumptions about analyte size and accessible surface area should be revisited for ion-pair RP separation of small peptides, typical for proteomic applications that are predominantly applying FA eluents. Hybrid silica-based materials with pore sizes of 130-200 angstrom should be specifically targeted for bottom-up proteomic applications to obtain both superior peak shape and peptide retentivity. This challenging task of attaining the best RPLC column for proteomics calls for closer collaboration between LC column manufacturers and proteomic LC specialists.
- 29 May 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (23) , 9721-9728
Paradigm Shift: Major Role of Ion-Pairing-Dependent Size Exclusion Effects in Bottom-Up Proteomics Reversed-Phase Peptide Separations
Can reversed-phase peptide retention be the same for C8 and C18 columns? or increase for otherwise identical columns with a smaller surface area? Can replacing trifluoroacetic acid (TFA) with formic acid (FA) improve the peak shape? According to our common understanding of peptide chromatography, absolutely not. Surprisingly, a thorough comparison of the peptide separation selectivity of 100 and 120 angstrom fully porous C18 sorbents to maximize the performance of our in-house proteomics LC-MS/MS setup revealed an unexpectedly higher peptide retentivity for a wider pore packing material, despite it having a smaller surface area. Concurrently, the observed increase in peptide retention-which drives variation in separation selectivity between 100 and 120 angstrom pore size materials-was more pronounced for smaller peptides. These findings contradict the central dogmas that underlie the development of all peptide RP-HPLC applications: (i) a larger surface area leads to higher retention and (ii) increasing the pore size should benefit the retention of larger analytes. Based on our intriguing findings, we compared reversed-phase high-performance liquid chromatography peptide retention for a total of 20 columns with pore sizes between 60 and 300 angstrom using FA- and TFA-based eluents. Our results unequivocally attest that the larger size of ion pairs in FA- vs TFA-based eluents leads to the observed impact on selectivity and peptide retention. For FA, peptide retention peaks at 200 angstrom pore size, compared to between 120 and 200 angstrom for TFA. However, the decrease in retention for narrow-pore particles is more profound in FA. Our findings suggest that common assumptions about analyte size and accessible surface area should be revisited for ion-pair RP separation of small peptides, typical for proteomic applications that are predominantly applying FA eluents. Hybrid silica-based materials with pore sizes of 130-200 angstrom should be specifically targeted for bottom-up proteomic applications to obtain both superior peak shape and peptide retentivity. This challenging task of attaining the best RPLC column for proteomics calls for closer collaboration between LC column manufacturers and proteomic LC specialists.
- 8 March 2024
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 23 (4) , 1360-1369
Accelerating Proteomics Using Broad Specificity Proteases
Trypsin is the gold-standard protease in bottom-up proteomics, but many sequence stretches of the proteome are inaccessible to trypsin and standard LC-MS approaches. Thus, multienzyme strategies are used to maximize sequence coverage in post-translational modification profiling. We present fast and robust SP3- and STRAP-based protocols for the broad-specificity proteases subtilisin, proteinase K, and thermolysin. All three enzymes are remarkably fast, producing near-complete digests in 1-5 min, and cost 200-1000× less than proteomics-grade trypsin. Using FragPipe resolved a major challenge by drastically reducing the duration of the required "unspecific" searches. In-depth analyses of proteinase K, subtilisin, and thermolysin Jurkat digests identified 7374, 8178, and 8753 unique proteins with average sequence coverages of 21, 29, and 37%, including 10,000s of amino acids not reported in PeptideAtlas' >2400 experiments. While we could not identify distinct cleavage patterns, machine learning could distinguish true protease products from random cleavages, potentially enabling the prediction of cleavage products. Finally, proteinase K, subtilisin, and thermolysin enabled label-free quantitation of 3111, 3659, and 4196 unique Jurkat proteins, which in our hands is comparable to trypsin. Our data demonstrate that broad-specificity proteases enable quantitative proteomics of uncharted areas of the proteome. Their fast kinetics may allow "on-the-fly" digestion of samples in the future.
- 8 March 2024
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 23 (4) , 1360-1369
Accelerating Proteomics Using Broad Specificity Proteases
Trypsin is the gold-standard protease in bottom-up proteomics, but many sequence stretches of the proteome are inaccessible to trypsin and standard LC-MS approaches. Thus, multienzyme strategies are used to maximize sequence coverage in post-translational modification profiling. We present fast and robust SP3- and STRAP-based protocols for the broad-specificity proteases subtilisin, proteinase K, and thermolysin. All three enzymes are remarkably fast, producing near-complete digests in 1-5 min, and cost 200-1000× less than proteomics-grade trypsin. Using FragPipe resolved a major challenge by drastically reducing the duration of the required "unspecific" searches. In-depth analyses of proteinase K, subtilisin, and thermolysin Jurkat digests identified 7374, 8178, and 8753 unique proteins with average sequence coverages of 21, 29, and 37%, including 10,000s of amino acids not reported in PeptideAtlas' >2400 experiments. While we could not identify distinct cleavage patterns, machine learning could distinguish true protease products from random cleavages, potentially enabling the prediction of cleavage products. Finally, proteinase K, subtilisin, and thermolysin enabled label-free quantitation of 3111, 3659, and 4196 unique Jurkat proteins, which in our hands is comparable to trypsin. Our data demonstrate that broad-specificity proteases enable quantitative proteomics of uncharted areas of the proteome. Their fast kinetics may allow "on-the-fly" digestion of samples in the future.
- 9 February 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1718, 464714
Retention time prediction for post-translationally modified peptides: Ser, Thr, Tyr-phosphorylation
- 9 February 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1718, 464714
Retention time prediction for post-translationally modified peptides: Ser, Thr, Tyr-phosphorylation
- 22 September 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (39) , 14634-14642
Compendium of Chromatographic Behavior of Post-translationally and Chemically Modified Peptides in Bottom-Up Proteomic Experiments
We have systematically evaluated the chromatographic behavior of post-translationally/chemically modified peptides using data spanning over 70 of the most relevant modifications. These retention properties were measured for standard bottom-up proteomic settings (fully porous C18 separation media, 0.1% formic acid as ion-pairing modifier) using collections of modified/nonmodified peptide pairs. These pairs were generated by spontaneous degradation, chemical or enzymatic treatment, analysis of synthetic peptides, or the cotranslational incorporation of noncanonical proline analogues. In addition, these measurements were validated using external data acquired for synthetic peptides and enzymatically induced citrullination. Working in units of hydrophobicity index (HI, % ACN) and evaluating the average retention shifts (?HI) represent the simplest approach to describe the effect of modifications from a didactic point of view. Plotting HI values for modified (y-axis) vs nonmodified (x-axis) counterparts generates unique slope and intercept values for each modification defined by the chemistry of the modifying moiety: its hydrophobicity, size, pK(a) of ionizable groups, and position of the altered residue. These composition-dependent correlations can be used for coarse incorporation of PTMs into models for prediction of peptide retention. More accurate predictions would require the development of specific sequence-dependent algorithms to predict ?HI values.
- 22 September 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (39) , 14634-14642
Compendium of Chromatographic Behavior of Post-translationally and Chemically Modified Peptides in Bottom-Up Proteomic Experiments
We have systematically evaluated the chromatographic behavior of post-translationally/chemically modified peptides using data spanning over 70 of the most relevant modifications. These retention properties were measured for standard bottom-up proteomic settings (fully porous C18 separation media, 0.1% formic acid as ion-pairing modifier) using collections of modified/nonmodified peptide pairs. These pairs were generated by spontaneous degradation, chemical or enzymatic treatment, analysis of synthetic peptides, or the cotranslational incorporation of noncanonical proline analogues. In addition, these measurements were validated using external data acquired for synthetic peptides and enzymatically induced citrullination. Working in units of hydrophobicity index (HI, % ACN) and evaluating the average retention shifts (?HI) represent the simplest approach to describe the effect of modifications from a didactic point of view. Plotting HI values for modified (y-axis) vs nonmodified (x-axis) counterparts generates unique slope and intercept values for each modification defined by the chemistry of the modifying moiety: its hydrophobicity, size, pK(a) of ionizable groups, and position of the altered residue. These composition-dependent correlations can be used for coarse incorporation of PTMs into models for prediction of peptide retention. More accurate predictions would require the development of specific sequence-dependent algorithms to predict ?HI values.
- Open Access
Deep learning from harmonized peptide libraries enables retention time prediction of diverse post translational modifications
In proteomics experiments, peptide retention time (RT) is an orthogonal property to fragmentation when assessing detection confidence. Advances in deep learning enable accurate RT prediction for any peptide from sequence alone, including those yet to be experimentally observed. Here we present Chronologer, an open-source software tool for rapid and accurate peptide RT prediction. Using new approaches to harmonize and false-discovery correct across independently collected datasets, Chronologer is built on a massive database with >2.2 million peptides including 10 common post-translational modification (PTM) types. By linking knowledge learned across diverse peptide chemistries, Chronologer predicts RTs with less than two-thirds the error of other deep learning tools. We show how RT for rare PTMs, such as OGlcNAc, can be learned with high accuracy using as few as 10-100 example peptides in newly harmonized datasets. This iteratively updatable workflow enables Chronologer to comprehensively predict RTs for PTM-marked peptides across entire proteomes.
Open AccessDeep learning from harmonized peptide libraries enables retention time prediction of diverse post translational modifications
In proteomics experiments, peptide retention time (RT) is an orthogonal property to fragmentation when assessing detection confidence. Advances in deep learning enable accurate RT prediction for any peptide from sequence alone, including those yet to be experimentally observed. Here we present Chronologer, an open-source software tool for rapid and accurate peptide RT prediction. Using new approaches to harmonize and false-discovery correct across independently collected datasets, Chronologer is built on a massive database with >2.2 million peptides including 10 common post-translational modification (PTM) types. By linking knowledge learned across diverse peptide chemistries, Chronologer predicts RTs with less than two-thirds the error of other deep learning tools. We show how RT for rare PTMs, such as OGlcNAc, can be learned with high accuracy using as few as 10-100 example peptides in newly harmonized datasets. This iteratively updatable workflow enables Chronologer to comprehensively predict RTs for PTM-marked peptides across entire proteomes.
- 16 June 2021
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 20 (7) , 3600-3610
Sequence-Specific Model for Predicting Peptide Collision Cross Section Values in Proteomic Ion Mobility Spectrometry
The contribution of peptide amino acid sequence to collision cross section values (CCS) has been investigated using a dataset of ∼134 000 peptides of four different charge states (1+ to 4+). The migration data were acquired using a two-dimensional liquid chromatography (LC)/trapped ion mobility spectrometry/quadrupole/time-of-flight mass spectrometry (MS) analysis of HeLa cell digests created using seven different proteases and was converted to CCS values. Following the previously reported modeling approaches using intrinsic size parameters (ISP), we extended this methodology to encode the position of individual residues within a peptide sequence. A generalized prediction model was built by dividing the dataset into eight groups (four charges for both tryptic/nontryptic peptides). Position-dependent ISPs were independently optimized for the eight subsets of peptides, resulting in prediction accuracy of ∼0.981 for the entire population of peptides. We find that ion mobility is strongly affected by the peptide’s ability to solvate the positively charged sites. Internal positioning of polar residues and proline leads to decreased CCS values as they improve charge solvation; conversely, this ability decreases with increasing peptide charge due to electrostatic repulsion. Furthermore, higher helical propensity and peptide hydrophobicity result in a preferential formation of extended structures with higher than predicted CCS values. Finally, acidic/basic residues exhibit position-dependent ISP behavior consistent with electrostatic interaction with the peptide macrodipole, which affects the peptide helicity. The MS raw data files have been deposited with the ProteomeXchange Consortium via the jPOST partner repository (http://jpostdb.org) with the dataset identifiers PXD021440/JPST000959, PXD022800/JPST001017, and PXD026087/ JPST001176.
- 16 June 2021
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 20 (7) , 3600-3610
Sequence-Specific Model for Predicting Peptide Collision Cross Section Values in Proteomic Ion Mobility Spectrometry
The contribution of peptide amino acid sequence to collision cross section values (CCS) has been investigated using a dataset of ∼134 000 peptides of four different charge states (1+ to 4+). The migration data were acquired using a two-dimensional liquid chromatography (LC)/trapped ion mobility spectrometry/quadrupole/time-of-flight mass spectrometry (MS) analysis of HeLa cell digests created using seven different proteases and was converted to CCS values. Following the previously reported modeling approaches using intrinsic size parameters (ISP), we extended this methodology to encode the position of individual residues within a peptide sequence. A generalized prediction model was built by dividing the dataset into eight groups (four charges for both tryptic/nontryptic peptides). Position-dependent ISPs were independently optimized for the eight subsets of peptides, resulting in prediction accuracy of ∼0.981 for the entire population of peptides. We find that ion mobility is strongly affected by the peptide’s ability to solvate the positively charged sites. Internal positioning of polar residues and proline leads to decreased CCS values as they improve charge solvation; conversely, this ability decreases with increasing peptide charge due to electrostatic repulsion. Furthermore, higher helical propensity and peptide hydrophobicity result in a preferential formation of extended structures with higher than predicted CCS values. Finally, acidic/basic residues exhibit position-dependent ISP behavior consistent with electrostatic interaction with the peptide macrodipole, which affects the peptide helicity. The MS raw data files have been deposited with the ProteomeXchange Consortium via the jPOST partner repository (http://jpostdb.org) with the dataset identifiers PXD021440/JPST000959, PXD022800/JPST001017, and PXD026087/ JPST001176.
- Open Access
Sequence-specific model for predicting peptide collision cross-section values in proteomic ion mobility spectrometry
The contribution of peptide amino-acid sequence to collision cross-section values (CCS) has been investigated using a dataset of ∼134,000 peptides of four different charge states (1+ to 4+). The migration data was acquired using a two-dimensional LC/trapped ion mobility spectrometry/quadrupole/time-of-flight MS analysis of HeLa cell digests created using 7 different proteases and was converted to CCS values. Following the previously reported modeling approaches using intrinsic size parameters (ISP), we extended this methodology to encode the position of individual residues within a peptide sequence. A generalized prediction model was built by dividing the dataset into 8 groups (four charges for both tryptic/non-tryptic peptides). Position dependent ISPs were independently optimized for the eight subsets of peptides, resulting in prediction accuracy of ∼0.981 for the entire population of peptides. We find that ion mobility is strongly affected by the peptide’s ability to solvate the positively charged sites. Internal positioning of polar residues and proline leads to decreased CCS values as they improve charge solvation; conversely, this ability decreases with increasing peptide charge due to electrostatic repulsion. Furthermore, higher helical propensity and peptide hydrophobicity result in preferential formation of extended structures with higher than predicted CCS values. Finally, acidic/basic residues exhibit position dependent ISP behaviour consistent with electrostatic interaction with the peptide macro-dipole, which affects the peptide helicity.
Open AccessSequence-specific model for predicting peptide collision cross-section values in proteomic ion mobility spectrometry
The contribution of peptide amino-acid sequence to collision cross-section values (CCS) has been investigated using a dataset of ∼134,000 peptides of four different charge states (1+ to 4+). The migration data was acquired using a two-dimensional LC/trapped ion mobility spectrometry/quadrupole/time-of-flight MS analysis of HeLa cell digests created using 7 different proteases and was converted to CCS values. Following the previously reported modeling approaches using intrinsic size parameters (ISP), we extended this methodology to encode the position of individual residues within a peptide sequence. A generalized prediction model was built by dividing the dataset into 8 groups (four charges for both tryptic/non-tryptic peptides). Position dependent ISPs were independently optimized for the eight subsets of peptides, resulting in prediction accuracy of ∼0.981 for the entire population of peptides. We find that ion mobility is strongly affected by the peptide’s ability to solvate the positively charged sites. Internal positioning of polar residues and proline leads to decreased CCS values as they improve charge solvation; conversely, this ability decreases with increasing peptide charge due to electrostatic repulsion. Furthermore, higher helical propensity and peptide hydrophobicity result in preferential formation of extended structures with higher than predicted CCS values. Finally, acidic/basic residues exhibit position dependent ISP behaviour consistent with electrostatic interaction with the peptide macro-dipole, which affects the peptide helicity.