Intraocular lens power calculation following laser refractive surgery
Open Access
- 2 April 2015
- journal article
- review article
- Published by Springer Nature in Eye and Vision
- Vol. 2 (1) , 1-8
Abstract
Refractive outcomes following cataract surgery in patients that have previously undergone laser refractive surgery have traditionally been underwhelming. This is related to several key issues including the preoperative assessment (keratometry) and intraocular lens power calculations. Peer-reviewed literature is overwhelmed by the influx of methodology to manipulate the corneal or intraocular lens (IOL) powers following refractive surgery. This would suggest that the optimal derivative formula has yet been introduced. This review discusses the problems facing surgeons approaching IOL calculations in these post-refractive laser patients, the existing formulae and programs to address these concerns. Prior published outcomes will be reviewed.Keywords
This publication has 78 references indexed in Scilit:
- Comparison of intraocular lens power calculation methods after myopic laser refractive surgery without previous refractive surgery dataJournal of Cataract & Refractive Surgery, 2013
- Intraocular Lens Power Adjustment After Myopic Excimer Laser SurgeryCornea, 2013
- A new central–peripheral corneal curvature method for intraocular lens power calculation after excimer laser refractive surgeryActa Ophthalmologica, 2013
- Accuracy of Intraocular Lens Calculation With Ray TracingJournal of Refractive Surgery, 2012
- Intraocular lens power calculation after previous myopic laser vision correction based on corneal power measured by Fourier-domain optical coherence tomographyJournal of Cataract & Refractive Surgery, 2012
- A Comparison of the American Society of Cataract and Refractive Surgery post-myopic LASIK/PRK Intraocular Lens (IOL) calculator and the Ocular MD IOL calculatorClinical Ophthalmology, 2011
- Intraocular Lens Power Calculations after Myopic Laser Refractive Surgery: A Comparison of Methods in 173 EyesOphthalmology, 2011
- Theoretical evaluation of the cataract extraction‐refraction‐implantation techniques for intraocular lens power calculationOphthalmic and Physiological Optics, 2008
- Measuring total corneal power before and after laser in situ keratomileusis with high-speed optical coherence tomographyJournal of Cataract & Refractive Surgery, 2006
- Calculation of intraocular lens power after corneal refractive surgeryClinical & Experimental Ophthalmology, 2006