Michael Lawless
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michael Lawless has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Chris Hodge
Vision Eye Institute Chatswood, Chatswood New South Wales Australia
5 shared publications Gerard Sutton
Vision Eye Institute, Sydney, New South Wales, Australia
5 shared publicationsChris Hodge
Vision Eye Institute Chatswood Sydney New South Wales Australia
3 shared publicationsTimothy V Roberts
Vision Eye Institute, Sydney, New South Wales, Australia
3 shared publications- Christopher Rogers
Ginzton Laboratory, Stanford University, 348 Via Pueblo, Stanford, California 94305, USA
2 shared publications - Gerard Sutton
Vision Eye Institute, Chatswood, Australia
2 shared publications
Latest Publications
- Open Access
- 1 July 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (7) , 549-556
Visual and participant-reported outcomes of a wavefront-shaping EDOF intraocular lens implanted bilaterally with monovision
Purpose: To report visual and participant-reported outcomes after bilateral implantation of nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof IQ Vivity) with monovision correction during cataract or refractive lens exchange (RLE) surgery. Setting: Europe, Australia, and New Zealand. Design: Subgroup analysis of Vivity registry. Methods: Binocular uncorrected and corrected visual acuities at distance (UDVA/CDVA), intermediate (UIVA/DCIVA), and near (UNVA/DCNVA) were assessed at 3 to 6 months after implantation. Participant-reported outcomes (satisfaction, spectacle independence, and visual disturbances) were evaluated. Data were reported by surgery type and monovision level at low (>−0.75 diopter [D] and ≤−0.50 D), medium (>−1.00 D and ≤−0.75 D), and high (≤−1.00 D). Results: Overall, 200 (of 885) participants met the monovision criteria (cataract, n = 170; RLE, n = 24). Excellent binocular UDVA and UIVA and excellent/good UNVA (mean ± SD logMAR) were noted for cataract (0.031 ± 0.102; 0.081 ± 0.114; 0.217 ± 0.144) and RLE (0.006 ± 0.093; −0.003 ± 0.089; 0.123 ± 0.097) groups, respectively. Most participants were spectacle-independent for distance and intermediate vision and very/fairly satisfied with sight; >87% from each surgery group reported no visual disturbances. Excellent UDVA was preserved at low and medium monovision. Better UNVA was observed for medium and high vs low monovision levels, whereas spectacle independence for distance and intermediate was higher for medium vs low/high monovision. High participant satisfaction and minimal visual disturbances were reported regardless of monovision level. Conclusions: Monovision correction with the nondiffractive EDOF IOL demonstrated excellent-to-good VA at all distances, high levels of spectacle independence and participant satisfaction, and minimal visual disturbances after cataract and RLE surgeries. Overall, medium monovision level performed most favorably, achieving good near VA while preserving excellent distance and intermediate vision.
- 1 July 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (7) , 549-556
Open AccessVisual and participant-reported outcomes of a wavefront-shaping EDOF intraocular lens implanted bilaterally with monovision
Purpose: To report visual and participant-reported outcomes after bilateral implantation of nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof IQ Vivity) with monovision correction during cataract or refractive lens exchange (RLE) surgery. Setting: Europe, Australia, and New Zealand. Design: Subgroup analysis of Vivity registry. Methods: Binocular uncorrected and corrected visual acuities at distance (UDVA/CDVA), intermediate (UIVA/DCIVA), and near (UNVA/DCNVA) were assessed at 3 to 6 months after implantation. Participant-reported outcomes (satisfaction, spectacle independence, and visual disturbances) were evaluated. Data were reported by surgery type and monovision level at low (>−0.75 diopter [D] and ≤−0.50 D), medium (>−1.00 D and ≤−0.75 D), and high (≤−1.00 D). Results: Overall, 200 (of 885) participants met the monovision criteria (cataract, n = 170; RLE, n = 24). Excellent binocular UDVA and UIVA and excellent/good UNVA (mean ± SD logMAR) were noted for cataract (0.031 ± 0.102; 0.081 ± 0.114; 0.217 ± 0.144) and RLE (0.006 ± 0.093; −0.003 ± 0.089; 0.123 ± 0.097) groups, respectively. Most participants were spectacle-independent for distance and intermediate vision and very/fairly satisfied with sight; >87% from each surgery group reported no visual disturbances. Excellent UDVA was preserved at low and medium monovision. Better UNVA was observed for medium and high vs low monovision levels, whereas spectacle independence for distance and intermediate was higher for medium vs low/high monovision. High participant satisfaction and minimal visual disturbances were reported regardless of monovision level. Conclusions: Monovision correction with the nondiffractive EDOF IOL demonstrated excellent-to-good VA at all distances, high levels of spectacle independence and participant satisfaction, and minimal visual disturbances after cataract and RLE surgeries. Overall, medium monovision level performed most favorably, achieving good near VA while preserving excellent distance and intermediate vision.
- 11 November 2024
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 52 (8) , 795-796
Is it time to consider how we approach bilateral same‐day cataract surgery?
- 11 November 2024
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 52 (8) , 795-796
Is it time to consider how we approach bilateral same‐day cataract surgery?
- Open Access
- 18 December 2022
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 16, 4227-4237
Visual and Refractive Efficacy of Panoptix Toric Intraocular Lens in a Clinical Setting
Purpose: Trifocal Intraocular Lenses (IOLs) were developed to provide patients with effective near, intermediate and distance vision, thus minimizing spectacle dependency. Residual astigmatism has previously been shown to impact unaided visual acuity across all distances; therefore, to optimise the expected outcomes, consideration of preoperative corneal astigmatism is essential. The purpose of this study was to provide a real-world, multi-site review of visual and refractive outcomes in eyes undergoing implantation with the Panoptix Trifocal toric IOL platform.Patients and Methods: This study represents a two-fold approach. Patients who had previously undergone routine cataract removal and IOL insertion with the Panoptix Toric IOL were retrospectively analysed for routine efficacy and safety endpoints ("Retrospective Cohort"). Data was retrieved from the preoperative, surgical and postoperative visits (range 2-6 weeks). A further subset of patients undergoing lens removal and bilateral Panoptix Toric IOL insertion were identified at surgery ("Qualitative Cohort"). These patients underwent additional testing inclusive of quality of vision questionnaire and bilateral defocus curve.Results: A total of 466 eyes of 254 patients were included in the retrospective cohort. Between 91% and 98% of eyes, respectively, were within 0.50D and 1.00D of target. Mean absolute difference from Spherical Equivalent (SE) target was 0.22 +/- 0.24Ds. Following surgery, 94% of eyes demonstrated a refractive astigmatism of 0.50D or less. Further, 61% eyes achieved uncorrected distance visual acuity (UDVA) of 20/20 or better, increasing to 94% achieving 20/32 or better. Seventy percent of eyes unilaterally achieved N5 unaided and 66.0% achieved N8 or better at intermediate. In the qualitative cohort, no patient described any symptom as significant or requested explant.Conclusion: In a real-world setting, the PanOptix toric trifocal IOL continues to demonstrate refractive accuracy and good visual performance at all focal distances. This IOL also exhibited good quality of vision, with minimally bothersome visual disturbances or photic phenomena.
- 18 December 2022
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 16, 4227-4237
Open AccessVisual and Refractive Efficacy of Panoptix Toric Intraocular Lens in a Clinical Setting
Purpose: Trifocal Intraocular Lenses (IOLs) were developed to provide patients with effective near, intermediate and distance vision, thus minimizing spectacle dependency. Residual astigmatism has previously been shown to impact unaided visual acuity across all distances; therefore, to optimise the expected outcomes, consideration of preoperative corneal astigmatism is essential. The purpose of this study was to provide a real-world, multi-site review of visual and refractive outcomes in eyes undergoing implantation with the Panoptix Trifocal toric IOL platform.Patients and Methods: This study represents a two-fold approach. Patients who had previously undergone routine cataract removal and IOL insertion with the Panoptix Toric IOL were retrospectively analysed for routine efficacy and safety endpoints ("Retrospective Cohort"). Data was retrieved from the preoperative, surgical and postoperative visits (range 2-6 weeks). A further subset of patients undergoing lens removal and bilateral Panoptix Toric IOL insertion were identified at surgery ("Qualitative Cohort"). These patients underwent additional testing inclusive of quality of vision questionnaire and bilateral defocus curve.Results: A total of 466 eyes of 254 patients were included in the retrospective cohort. Between 91% and 98% of eyes, respectively, were within 0.50D and 1.00D of target. Mean absolute difference from Spherical Equivalent (SE) target was 0.22 +/- 0.24Ds. Following surgery, 94% of eyes demonstrated a refractive astigmatism of 0.50D or less. Further, 61% eyes achieved uncorrected distance visual acuity (UDVA) of 20/20 or better, increasing to 94% achieving 20/32 or better. Seventy percent of eyes unilaterally achieved N5 unaided and 66.0% achieved N8 or better at intermediate. In the qualitative cohort, no patient described any symptom as significant or requested explant.Conclusion: In a real-world setting, the PanOptix toric trifocal IOL continues to demonstrate refractive accuracy and good visual performance at all focal distances. This IOL also exhibited good quality of vision, with minimally bothersome visual disturbances or photic phenomena.
- 9 August 2021
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (4) , 387-392
Prevalence of tear film hyperosmolarity in 1150 patients presenting for refractive surgery assessment
Purpose: To present an analysis of tear film hyperosmolarity in a large, consecutive population and evaluate the correlation of ocular and systemic conditions with tear film osmolarity (TFO). Setting: Private practice, Sydney, Australia. Design: Single-center, retrospective, consecutive cohort. Method: Patients undergoing screening for laser refractive surgery from October 2017 to October 2020 were retrospectively reviewed. 1404 patients (n = 1357 standard, n = 47 postrefractive) undergoing screening for laser refractive surgery from October 2017 to October 2020 were reviewed. Routine examination included TFO and Ocular Surface Disease Index (OSDI) questionnaire. TFO was conducted prior to further tests, and patients refrained from topical eyedrops minimum 2 hours before the appointment. Results: 1404 patients (n = 1357 standards, n = 47 postrefractive) patients were reviewed. Mean highest TFO in the standard population was 299.12 ± 11.94 mOsm/L, with 82.3% of eyes P = .012). Significant correlation was demonstrated between TFO scores and OSDI normal classification in the standard population only (P = .005, r = 0.077). The use of contact lens correlated inversely with TFO and OSDI scores (P = .000, r = −0.136, and P = .000, r = −0.152, respectively). Conclusions: To the authors' knowledge, this study represents the largest available cohort of TFO scores in a standard population presenting for refractive surgery. Although most patients were found to fall within normal ranges, a reasonable percentage were diagnosed with tear hyperosmolarity and therefore at risk for dry eye disease.
- 9 August 2021
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (4) , 387-392
Prevalence of tear film hyperosmolarity in 1150 patients presenting for refractive surgery assessment
Purpose: To present an analysis of tear film hyperosmolarity in a large, consecutive population and evaluate the correlation of ocular and systemic conditions with tear film osmolarity (TFO). Setting: Private practice, Sydney, Australia. Design: Single-center, retrospective, consecutive cohort. Method: Patients undergoing screening for laser refractive surgery from October 2017 to October 2020 were retrospectively reviewed. 1404 patients (n = 1357 standard, n = 47 postrefractive) undergoing screening for laser refractive surgery from October 2017 to October 2020 were reviewed. Routine examination included TFO and Ocular Surface Disease Index (OSDI) questionnaire. TFO was conducted prior to further tests, and patients refrained from topical eyedrops minimum 2 hours before the appointment. Results: 1404 patients (n = 1357 standards, n = 47 postrefractive) patients were reviewed. Mean highest TFO in the standard population was 299.12 ± 11.94 mOsm/L, with 82.3% of eyes P = .012). Significant correlation was demonstrated between TFO scores and OSDI normal classification in the standard population only (P = .005, r = 0.077). The use of contact lens correlated inversely with TFO and OSDI scores (P = .000, r = −0.136, and P = .000, r = −0.152, respectively). Conclusions: To the authors' knowledge, this study represents the largest available cohort of TFO scores in a standard population presenting for refractive surgery. Although most patients were found to fall within normal ranges, a reasonable percentage were diagnosed with tear hyperosmolarity and therefore at risk for dry eye disease.
- 10 January 2021
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 49 (1) , 88-89
Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery: Response
- 10 January 2021
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 49 (1) , 88-89
Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery: Response
- 27 May 2020
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 48 (7) , 998-1001
Understanding chord mu through a large population‐based study
- 27 May 2020
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 48 (7) , 998-1001
Understanding chord mu through a large population‐based study
- 12 April 2020
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 48 (6) , 749-756
Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery
Importance: Intraocular lens (IOL) calculations in post‐refractive cases remain a concern. Our study identifies improved options for surgeons.Background: To evaluate and compare the prediction accuracy of IOL power calculation methods after previous laser refractive surgery using standard keratometry (SK), measured posterior corneal astigmatism (PCA) and total keratometry (TK).Design: Retrospective consecutive cohort.Participants: A total of 50 consecutive patients (72 eyes) at a private institution who underwent cataract surgery with prior laser refractive procedures.Methods: Methods using SK included ASCRS mean, Barrett True‐K no history, Haigis‐L and Shammas IOL formulae. Barrett True‐K using posterior values (True K TK), Haigis and Holladay 1 Double‐K methods using TK were also assessed. Post‐surgery refraction was undertaken at minimum 3 weeks following surgery.Main Outcome Measures: Arithmetic and absolute IOL refractive prediction errors, variances in mean arithmetic IOL prediction error, and percentage of eyes within ±0.25D, ±0.50D, ±0.75D and ±1.00D of refractive prediction errors were compared.Results: The Barrett True‐K (TK) provided the lowest mean refractive prediction error (RPE) and variance for both prior myopes and hyperopes undergoing cataract surgery. The Barrett True‐K (TK) exhibited the highest percentages of eyes within ±0.50D, ±0.75D and ±1.00D of the RPE compared to other formulae for prior myopic patients.Conclusions and Relevance: Accuracy of IOL power calculations in post‐laser eyes can be improved by the addition of posterior corneal values as measured by the IOLMaster 700. The use of total keratometry may supplement outcomes when no prior refraction history is known.
- 12 April 2020
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 48 (6) , 749-756
Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery
Importance: Intraocular lens (IOL) calculations in post‐refractive cases remain a concern. Our study identifies improved options for surgeons.Background: To evaluate and compare the prediction accuracy of IOL power calculation methods after previous laser refractive surgery using standard keratometry (SK), measured posterior corneal astigmatism (PCA) and total keratometry (TK).Design: Retrospective consecutive cohort.Participants: A total of 50 consecutive patients (72 eyes) at a private institution who underwent cataract surgery with prior laser refractive procedures.Methods: Methods using SK included ASCRS mean, Barrett True‐K no history, Haigis‐L and Shammas IOL formulae. Barrett True‐K using posterior values (True K TK), Haigis and Holladay 1 Double‐K methods using TK were also assessed. Post‐surgery refraction was undertaken at minimum 3 weeks following surgery.Main Outcome Measures: Arithmetic and absolute IOL refractive prediction errors, variances in mean arithmetic IOL prediction error, and percentage of eyes within ±0.25D, ±0.50D, ±0.75D and ±1.00D of refractive prediction errors were compared.Results: The Barrett True‐K (TK) provided the lowest mean refractive prediction error (RPE) and variance for both prior myopes and hyperopes undergoing cataract surgery. The Barrett True‐K (TK) exhibited the highest percentages of eyes within ±0.50D, ±0.75D and ±1.00D of the RPE compared to other formulae for prior myopic patients.Conclusions and Relevance: Accuracy of IOL power calculations in post‐laser eyes can be improved by the addition of posterior corneal values as measured by the IOLMaster 700. The use of total keratometry may supplement outcomes when no prior refraction history is known.
- 31 August 2017
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 46 (3) , 240-246
Comparison of Hill‐radial basis function, Barrett Universal and current third generation formulas for the calculation of intraocular lens power during cataract surgery
Importance: This study represents a novel comparison of recently introduced intraocular lens power calculation formulas.Background: To compare current new generation formulas for calculating the intraocular lens power for a standard cohort of patients undergoing cataract and lens replacement surgery in a private group practice in Australia.Design: Retrospective case series comparison.Participants: Postoperative results from 400 consecutive patients undergoing implantation of an SN60WF intraocular lens post cataract removal by 12 surgeons were used.Methods: Refractive outcomes were compared with expected targets to determine the predicted refractive outcomes using the Hill‐radial basis function, Barrett Universal II and readily available third or fourth generation intraocular lens power calculation formulas.Main Outcome Measure: Mean absolute predicted error.Results: The mean absolute predicted difference ranged from 0.30 to 0.34 D. There was no overall significant difference in the predicted difference or variance between formulas. All formulas achieved greater than 78.3% of eyes within ±0.5 D of intended refraction. The Hill‐radial basis function and Barrett formulas provided the lowest mean numerical error compared with existing formulas in short and long eyes, respectively. The Barrett Universal II formula had the lowest percentage of refractive surprises (>1 D from predicted error) across all axial lengths.Conclusions and Relevance: Acceptable outcomes can be achieved with optical biometry, consistent surgical technique and use of current intraocular lens power calculation formulas. The Barrett Universal II formula may provide the lowest risk of refractive surprise compared with other intraocular lens power calculation formulas.
- 31 August 2017
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 46 (3) , 240-246
Comparison of Hill‐radial basis function, Barrett Universal and current third generation formulas for the calculation of intraocular lens power during cataract surgery
Importance: This study represents a novel comparison of recently introduced intraocular lens power calculation formulas.Background: To compare current new generation formulas for calculating the intraocular lens power for a standard cohort of patients undergoing cataract and lens replacement surgery in a private group practice in Australia.Design: Retrospective case series comparison.Participants: Postoperative results from 400 consecutive patients undergoing implantation of an SN60WF intraocular lens post cataract removal by 12 surgeons were used.Methods: Refractive outcomes were compared with expected targets to determine the predicted refractive outcomes using the Hill‐radial basis function, Barrett Universal II and readily available third or fourth generation intraocular lens power calculation formulas.Main Outcome Measure: Mean absolute predicted error.Results: The mean absolute predicted difference ranged from 0.30 to 0.34 D. There was no overall significant difference in the predicted difference or variance between formulas. All formulas achieved greater than 78.3% of eyes within ±0.5 D of intended refraction. The Hill‐radial basis function and Barrett formulas provided the lowest mean numerical error compared with existing formulas in short and long eyes, respectively. The Barrett Universal II formula had the lowest percentage of refractive surprises (>1 D from predicted error) across all axial lengths.Conclusions and Relevance: Acceptable outcomes can be achieved with optical biometry, consistent surgical technique and use of current intraocular lens power calculation formulas. The Barrett Universal II formula may provide the lowest risk of refractive surprise compared with other intraocular lens power calculation formulas.
- Open Access
- 4 April 2017
- Published by Springer Nature in Eye and Vision
- Vol. 4 (1) , 10
Visual and refractive outcomes following implantation of a new trifocal intraocular lens
Independence from all optical aids, and freedom from unwanted symptoms, following cataract and lens surgery remains the ultimate goal of both patient and surgeon. The development of trifocal IOL technology provides an ever-increasing range of options. The purpose of our study is to understand the predictability, safety and efficacy of a new trifocal intraocular lens (IOL) following cataract or refractive lens exchange (RLE) surgery. This was a retrospective consecutive case series of patients undergoing cataract extraction or RLE followed by implantation of the Alcon IQ Panoptix IOL. Pre and postoperative refractive and visual parameters were recorded and evaluated. As the cohort followed a normal distribution, standard parametric tests were used. Paired t-test was used to compare the difference between target and postoperative refractive errors. The incidence of intraoperative and postoperative complications was also reported. The IOL was implanted in 66 eyes of 33 patients. Mean postoperative spherical equivalent (SE) refraction was -0.08 ± 0.25 dioptres (D). This was not significantly different from the target refraction (p = 0.841). Sixty-five percent of patients were within ± 0.25 D of the target SE refraction with 100% within ± 0.50 D of intended correction. Mean postoperative uncorrected distance visual acuity (UDVA) was 0.01 ± 0.10 LogMAR. All patients achieved an unaided distance acuity of 20/40 or better postoperatively. Binocularly, 100% saw 0.20 LogMAR or better at near without correction and 88.9% achieved this level for uncorrected intermediate visual acuity. No intraoperative complications were noted. Five patients complained of moderate haloes in the early postoperative period. The AcrySof IQ Panoptix IOL provides functional uncorrected visual acuity at distance, intermediate and near positions. Our results remain equivalent with existing trifocal IOL outcomes and provide surgeons with a further IOL alternative for the patient motivated to obtain true spectacle independence. Surgeons should consider individual reading and working requirements when counselling patients preoperatively to optimise postoperative patient satisfaction.
- 4 April 2017
- Published by Springer Nature in Eye and Vision
- Vol. 4 (1) , 10
Open AccessVisual and refractive outcomes following implantation of a new trifocal intraocular lens
Independence from all optical aids, and freedom from unwanted symptoms, following cataract and lens surgery remains the ultimate goal of both patient and surgeon. The development of trifocal IOL technology provides an ever-increasing range of options. The purpose of our study is to understand the predictability, safety and efficacy of a new trifocal intraocular lens (IOL) following cataract or refractive lens exchange (RLE) surgery. This was a retrospective consecutive case series of patients undergoing cataract extraction or RLE followed by implantation of the Alcon IQ Panoptix IOL. Pre and postoperative refractive and visual parameters were recorded and evaluated. As the cohort followed a normal distribution, standard parametric tests were used. Paired t-test was used to compare the difference between target and postoperative refractive errors. The incidence of intraoperative and postoperative complications was also reported. The IOL was implanted in 66 eyes of 33 patients. Mean postoperative spherical equivalent (SE) refraction was -0.08 ± 0.25 dioptres (D). This was not significantly different from the target refraction (p = 0.841). Sixty-five percent of patients were within ± 0.25 D of the target SE refraction with 100% within ± 0.50 D of intended correction. Mean postoperative uncorrected distance visual acuity (UDVA) was 0.01 ± 0.10 LogMAR. All patients achieved an unaided distance acuity of 20/40 or better postoperatively. Binocularly, 100% saw 0.20 LogMAR or better at near without correction and 88.9% achieved this level for uncorrected intermediate visual acuity. No intraoperative complications were noted. Five patients complained of moderate haloes in the early postoperative period. The AcrySof IQ Panoptix IOL provides functional uncorrected visual acuity at distance, intermediate and near positions. Our results remain equivalent with existing trifocal IOL outcomes and provide surgeons with a further IOL alternative for the patient motivated to obtain true spectacle independence. Surgeons should consider individual reading and working requirements when counselling patients preoperatively to optimise postoperative patient satisfaction.
- Open Access
- 1 January 2017
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 65 (12) , 1314-1322
Reviewing the visual benefits of femtosecond laser-assisted cataract surgery: Can we improve our outcomes?
Femtosecond laser-assisted cataract surgery (FLACS) was introduced in 2009 and has increasingly been incorporated into surgical practice. The automation of three key aspects of cataract surgery was expected to deliver a significant improvement in both refractive and safety outcomes. The published literature has not yet shown consistent refractive improvement above conventional techniques. The purpose of this paper is to review current FLACS refractive outcomes and explore factors that may have contributed to the current findings and whether future improvements are possible.
- 1 January 2017
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 65 (12) , 1314-1322
Open AccessReviewing the visual benefits of femtosecond laser-assisted cataract surgery: Can we improve our outcomes?
Femtosecond laser-assisted cataract surgery (FLACS) was introduced in 2009 and has increasingly been incorporated into surgical practice. The automation of three key aspects of cataract surgery was expected to deliver a significant improvement in both refractive and safety outcomes. The published literature has not yet shown consistent refractive improvement above conventional techniques. The purpose of this paper is to review current FLACS refractive outcomes and explore factors that may have contributed to the current findings and whether future improvements are possible.