Accuracy of percutaneous pedicle screw placement with 3-dimensional fluoroscopy-based navigation: Lateral decubitus position versus prone position
Open Access
- 7 April 2023
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine
- Vol. 102 (14) , e33451
Abstract
The accuracy of percutaneous pedicle screw (PSS) placement in the lateral decubitus position has seldom been reported. This study aimed to retrospectively compare the accuracy of PPS placement with 3-dimensional (3D) fluoroscopy-based navigation in 2 cohorts of patients who underwent surgery in the lateral decubitus or prone positions at our single institute. A total of 265 consecutive patients underwent spinal surgery with PPS from T1 (thoracic 1) to S (sacrum) under the 3D fluoroscopy-based navigation system at our institute. Patients were divided into 2 groups based on their intraoperative patient positioning: lateral decubitus (Group L) or prone (Group P). A total of 1816 PPSs were placed from T1 to S, and 76 (4.18%) PPSs were assessed as deviated PPS. Twenty-one of 453 (4.64%) PPSs in Group L deviation and 55 of 1363 (4.04%) PPSs in Group P had deviated PPS, but with not significant difference (P = .580). In Group L, although the PPS deviation rate was not significantly different between the upside and downside PPS, the downside PPS significantly deviated toward the lateral side compared with the upside PPS. The safety and efficacy of PPS insertion in the lateral decubitus position were similar to those in the conventional prone position.Keywords
This publication has 16 references indexed in Scilit:
- Accuracy of pedicle screw placement in the thoracic and lumbosacral spines using O-arm-based navigation versus conventional freehand techniqueChinese Neurosurgical Journal, 2019
- MIS Single-position Lateral and Oblique Lateral Lumbar Interbody Fusion and Bilateral Pedicle Screw FixationSpine, 2018
- Clinical outcomes following spinal fusion using an intraoperative computed tomographic 3D imaging systemJournal of Neurosurgery: Spine, 2017
- Are pedicle screw perforation rates influenced by distance from the reference frame in multilevel registration using a computed tomography-based navigation system in the setting of scoliosis?The Spine Journal, 2017
- Thoracolumbar instrumentation with CT-guided navigation (O-arm) in 270 consecutive patients: accuracy rates and lessons learnedNeurosurgical Focus, 2014
- Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniquesEuropean Spine Journal, 2011
- Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: comparison between free-hand and O-arm based navigation techniquesEuropean Spine Journal, 2011
- Clinical Accuracy of Computer-Assisted Two-Dimensional Fluoroscopy for the Percutaneous Placement of Lumbosacral Pedicle ScrewsSpine, 2011
- Biomechanical Analysis and Review of Lateral Lumbar Fusion ConstructsSpine, 2010
- Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screwsEuropean Spine Journal, 2010