Tomohiro Inoue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tomohiro Inoue has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Ryuichiro Okuda
Department of Orthopaedic Surgery, Section of Medicine, Division of Medicine, Dentistry and Pharmaceutical Sciences, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan
4 shared publications - Kazuki Yamada
Department of Orthopaedic Surgery, Faculty of Medical Development Field, Okayama University, Okayama, Japan
3 shared publications - Tomonori Tetsunaga
Okayama University
3 shared publications - Toshifumi Ozaki
Department of Orthopaedic Surgery, Okayama University Hospital, Okayama, Japan
3 shared publications - Hisanori Ikuma
Department of Orthopaedic Surgery, Kagawa Prefectural Central Hospital, Kagawa, Japan
2 shared publications - Takashi Koura
Department of Orthopaedic Surgery, Dentistry and Pharmaceutical Sciences, Okayama University Graduate School of Medicine, Okayama, Japan
2 shared publications
Latest Publications
- Open Access
- 6 August 2026
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1) , 285
Accuracy of iliac crest reference pin placement in total hip arthroplasty: a CT-based analysis of risk factors for cortical perforation
- 6 August 2026
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1) , 285
Open AccessAccuracy of iliac crest reference pin placement in total hip arthroplasty: a CT-based analysis of risk factors for cortical perforation
- Open Access
- 15 July 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-8
Changes in the anatomical positions of the femoral nerve and artery in the lateral and supine positions: a multicenter retrospective study
Introduction: Femoral nerve palsy and femoral artery injury are serious complications of total hip arthroplasty. However, few studies have compared the anatomical positions of these structures in different patient positions. This study aimed to compare the anatomical positions of the femoral nerve and artery in the lateral and supine positions. Materials and methods: This multicenter retrospective study included 111 patients who underwent lateral and supine computed tomography (CT) from 2016 to 2023. CT images were reconstructed in the anterior pelvic plane. The horizontal distance from the anterior margin of the acetabulum to the femoral nerve (Distance N) and femoral artery (Distance A) was measured. The difference in Distance N between the two positions (ΔLateral–supine Distance N) was calculated by subtracting the supine value from the lateral value. Results: The average Distance N was 26.5 ± 5.1 mm in the lateral position and 21.1 ± 4.4 mm in the supine position, with the nerve located significantly closer to the acetabulum in the supine position (P < 0.001). Similarly, the average Distance A was 26.8 ± 5.4 mm in the lateral position and 20.4 ± 4.9 mm in the supine position (P < 0.001). Multiple regression analysis showed that Distance N in the lateral position was significantly shorter in female patients and those with low body weight. In addition, low body weight correlated with a smaller ΔLateral–supine Distance N. Conclusions: The femoral nerve and artery are located closer to the anterior margin of the acetabulum in the supine position than in the lateral position. Low body weight was an independent predictor of shorter Distance N in both positions and a smaller ΔLateral–supine Distance N. These findings underscore the importance of considering patient positioning during total hip arthroplasty, particularly in patients with low body weight, to reduce neurovascular risks.
- 15 July 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-8
Open AccessChanges in the anatomical positions of the femoral nerve and artery in the lateral and supine positions: a multicenter retrospective study
Introduction: Femoral nerve palsy and femoral artery injury are serious complications of total hip arthroplasty. However, few studies have compared the anatomical positions of these structures in different patient positions. This study aimed to compare the anatomical positions of the femoral nerve and artery in the lateral and supine positions. Materials and methods: This multicenter retrospective study included 111 patients who underwent lateral and supine computed tomography (CT) from 2016 to 2023. CT images were reconstructed in the anterior pelvic plane. The horizontal distance from the anterior margin of the acetabulum to the femoral nerve (Distance N) and femoral artery (Distance A) was measured. The difference in Distance N between the two positions (ΔLateral–supine Distance N) was calculated by subtracting the supine value from the lateral value. Results: The average Distance N was 26.5 ± 5.1 mm in the lateral position and 21.1 ± 4.4 mm in the supine position, with the nerve located significantly closer to the acetabulum in the supine position (P < 0.001). Similarly, the average Distance A was 26.8 ± 5.4 mm in the lateral position and 20.4 ± 4.9 mm in the supine position (P < 0.001). Multiple regression analysis showed that Distance N in the lateral position was significantly shorter in female patients and those with low body weight. In addition, low body weight correlated with a smaller ΔLateral–supine Distance N. Conclusions: The femoral nerve and artery are located closer to the anterior margin of the acetabulum in the supine position than in the lateral position. Low body weight was an independent predictor of shorter Distance N in both positions and a smaller ΔLateral–supine Distance N. These findings underscore the importance of considering patient positioning during total hip arthroplasty, particularly in patients with low body weight, to reduce neurovascular risks.
- Open Access
Accuracy Verification of a Computed Tomography-Based Navigation System for Total Hip Arthroplasty in Severe Hip Dysplasia: A Simulation Study Using 3D-Printed Bone Models of Crowe Types II, III, and IV
Background and Objective: The use of computed tomography (CT)-based navigation systems has been shown to improve surgical accuracy in total hip arthroplasty. However, there is limited literature available about the application of CT-based navigation systems in severe hip dysplasia. This study aimed to evaluate the accuracy of a CT-based navigation system in patients with severe hip dysplasia using three-dimensional (3D)-printed bone models. Methods: 3D-printed bone models were generated from CT data of patients with severe hip dysplasia (Crowe type II, 10 hips; type III, 10 hips; and type IV, 10 hips). The accuracy of automatic segmentation, success rate, point-matching accuracy across different registration methods, and deviation values at reference points after registration were assessed. Results: For the combined cohort of Crowe II, III, and IV cases (n = 30), the Dice Similarity Coefficient and Jaccard Index were 0.99 ± 0.01 and 0.98 ± 0.02, respectively. These values indicate a high level of segmentation accuracy. The “Matching with true and false acetabulum + iliac crest” method achieved a 100% success rate across all groups, with mean deviations of 0.08 ± 0.28 mm in the Crowe II group, 0.12 ± 0.33 mm in the Crowe III group, and 0.14 ± 0.50 mm in the Crowe IV group (p = 0.572). In the Crowe IV group, the anterior superior iliac spine deviation was significantly lower using the “Matching with true and false acetabulum + iliac crest” method compared to the “Matching with true and false acetabulum” method (0.28 ± 0.49 mm vs. 3.29 ± 2.56 mm, p < 0.05). Conclusions: This study demonstrated the high accuracy of automatic AI-based segmentation, with a Dice Similarity Coefficient of 0.99 ± 0.01 and a Jaccard Index of 0.98 ± 0.02 in the combined cohort of Crowe type II, III, and IV cases (n = 30). The matching success rate was 100%, with additional points on the iliac crest, which improved matching accuracy and reduced deviations, depending on the case.
Open AccessAccuracy Verification of a Computed Tomography-Based Navigation System for Total Hip Arthroplasty in Severe Hip Dysplasia: A Simulation Study Using 3D-Printed Bone Models of Crowe Types II, III, and IV
Background and Objective: The use of computed tomography (CT)-based navigation systems has been shown to improve surgical accuracy in total hip arthroplasty. However, there is limited literature available about the application of CT-based navigation systems in severe hip dysplasia. This study aimed to evaluate the accuracy of a CT-based navigation system in patients with severe hip dysplasia using three-dimensional (3D)-printed bone models. Methods: 3D-printed bone models were generated from CT data of patients with severe hip dysplasia (Crowe type II, 10 hips; type III, 10 hips; and type IV, 10 hips). The accuracy of automatic segmentation, success rate, point-matching accuracy across different registration methods, and deviation values at reference points after registration were assessed. Results: For the combined cohort of Crowe II, III, and IV cases (n = 30), the Dice Similarity Coefficient and Jaccard Index were 0.99 ± 0.01 and 0.98 ± 0.02, respectively. These values indicate a high level of segmentation accuracy. The “Matching with true and false acetabulum + iliac crest” method achieved a 100% success rate across all groups, with mean deviations of 0.08 ± 0.28 mm in the Crowe II group, 0.12 ± 0.33 mm in the Crowe III group, and 0.14 ± 0.50 mm in the Crowe IV group (p = 0.572). In the Crowe IV group, the anterior superior iliac spine deviation was significantly lower using the “Matching with true and false acetabulum + iliac crest” method compared to the “Matching with true and false acetabulum” method (0.28 ± 0.49 mm vs. 3.29 ± 2.56 mm, p < 0.05). Conclusions: This study demonstrated the high accuracy of automatic AI-based segmentation, with a Dice Similarity Coefficient of 0.99 ± 0.01 and a Jaccard Index of 0.98 ± 0.02 in the combined cohort of Crowe type II, III, and IV cases (n = 30). The matching success rate was 100%, with additional points on the iliac crest, which improved matching accuracy and reduced deviations, depending on the case.
- Open Access
- 7 April 2023
- Published by Wolters Kluwer Health in Medicine
- Vol. 102 (14) , e33451
Accuracy of percutaneous pedicle screw placement with 3-dimensional fluoroscopy-based navigation: Lateral decubitus position versus prone position
The accuracy of percutaneous pedicle screw (PSS) placement in the lateral decubitus position has seldom been reported. This study aimed to retrospectively compare the accuracy of PPS placement with 3-dimensional (3D) fluoroscopy-based navigation in 2 cohorts of patients who underwent surgery in the lateral decubitus or prone positions at our single institute. A total of 265 consecutive patients underwent spinal surgery with PPS from T1 (thoracic 1) to S (sacrum) under the 3D fluoroscopy-based navigation system at our institute. Patients were divided into 2 groups based on their intraoperative patient positioning: lateral decubitus (Group L) or prone (Group P). A total of 1816 PPSs were placed from T1 to S, and 76 (4.18%) PPSs were assessed as deviated PPS. Twenty-one of 453 (4.64%) PPSs in Group L deviation and 55 of 1363 (4.04%) PPSs in Group P had deviated PPS, but with not significant difference (P = .580). In Group L, although the PPS deviation rate was not significantly different between the upside and downside PPS, the downside PPS significantly deviated toward the lateral side compared with the upside PPS. The safety and efficacy of PPS insertion in the lateral decubitus position were similar to those in the conventional prone position.
- 7 April 2023
- Published by Wolters Kluwer Health in Medicine
- Vol. 102 (14) , e33451
Open AccessAccuracy of percutaneous pedicle screw placement with 3-dimensional fluoroscopy-based navigation: Lateral decubitus position versus prone position
The accuracy of percutaneous pedicle screw (PSS) placement in the lateral decubitus position has seldom been reported. This study aimed to retrospectively compare the accuracy of PPS placement with 3-dimensional (3D) fluoroscopy-based navigation in 2 cohorts of patients who underwent surgery in the lateral decubitus or prone positions at our single institute. A total of 265 consecutive patients underwent spinal surgery with PPS from T1 (thoracic 1) to S (sacrum) under the 3D fluoroscopy-based navigation system at our institute. Patients were divided into 2 groups based on their intraoperative patient positioning: lateral decubitus (Group L) or prone (Group P). A total of 1816 PPSs were placed from T1 to S, and 76 (4.18%) PPSs were assessed as deviated PPS. Twenty-one of 453 (4.64%) PPSs in Group L deviation and 55 of 1363 (4.04%) PPSs in Group P had deviated PPS, but with not significant difference (P = .580). In Group L, although the PPS deviation rate was not significantly different between the upside and downside PPS, the downside PPS significantly deviated toward the lateral side compared with the upside PPS. The safety and efficacy of PPS insertion in the lateral decubitus position were similar to those in the conventional prone position.