Automatic versus manual oxygen titration using a novel nasal high-flow device in medical inpatients with an acute illness: a randomised controlled trial
Open Access
- 6 August 2021
- journal article
- research article
- Published by BMJ in BMJ Open Respiratory Research
- Vol. 8 (1) , e000843
Abstract
Background: Guideline recommendations state oxygen should be administered to acutely unwell patients to achieve a target oxygen saturation (SpO2) range. The current practice of manual oxygen titration frequently results in SpO2 outside of a prescribed range. The aim of this study was to assess the efficacy of automatic oxygen titration using a closed-loop feedback system to achieve SpO2 within a prescribed target range Methods: An open-label randomised parallel group trial was undertaken comparing automatic oxygen titration using a novel nasal high-flow device to manual oxygen titration using nasal high flow. Medical inpatients requiring oxygen therapy in Wellington Regional Hospital, New Zealand with a prescribed target SpO2 range of 88%–92% or 92%–96% were recruited and randomised equally between the interventions for a period of 24 hours. The primary outcome was the proportion of time spent with SpO2 within the prescribed range. Results: 20 patients were included in the analysis. Automatic oxygen titration resulted in a median (IQR) 96.2% (95.2–97.8) of time within the target range compared with 71% (59.4–88.3) with manual titration; difference (95% CI) 24.2% (7.9% to 35%), p2 ≥2% above and ≥2% below range in the automatic titration group, although the point estimate for the differences were small; −1% (−8.2% to −0.04%), p=0.017 and −2.4% (−11.5% to 0.3%), p=0.05 respectively. Conclusions: Nasal high-flow with automatic oxygen titration resulted in a greater proportion of time spent with SpO2 in target range compared with manual titration. Trial registration: The trial was registered with the Australian and New Zealand Clinical Trials Registry (ACTRN12619000901101).Keywords
Funding Information
- Fisher and Paykel Healthcare (Not applicable)
This publication has 26 references indexed in Scilit:
- Physiologic Effects of High-Flow Nasal Cannula in Acute Hypoxemic Respiratory FailureAmerican Journal of Respiratory and Critical Care Medicine, 2017
- Nasal high flow reduces dead spaceJournal of Applied Physiology, 2017
- Automated oxygen titration and weaning with FreeO2 in patients with acute exacerbation of COPD: a pilot randomized trialInternational Journal of Chronic Obstructive Pulmonary Disease, 2016
- ThoracicSociety ofAustralia andNewZealand oxygen guidelines for acute oxygen use in adults: ‘Swimming between the flags’Respirology, 2015
- Pressures Delivered By Nasal High Flow Oxygen During All Phases of the Respiratory CycleRespiratory Care, 2013
- Evaluation of a Humidified Nasal High-Flow Oxygen System, Using Oxygraphy, Capnography and Measurement of Upper Airway PressuresAnaesthesia and Intensive Care, 2011
- British Thoracic Society emergency oxygen auditsThorax, 2011
- Research electronic data capture (REDCap)—A metadata-driven methodology and workflow process for providing translational research informatics supportJournal of Biomedical Informatics, 2009
- Performance of six types of oxygen delivery devices at varying respiratory rates*Anaesthesia, 2007
- Association between clinically abnormal observations and subsequent in-hospital mortality: a prospective studyResuscitation, 2004