    Closed-Loop Oxygen Control

    by James Harper

    Guidelines recommend that oxygen should be titrated to achieve a target oxygen saturation (SpO2 ) range in acutely unwell patients, a concept colloquially known as “swimming between the flags”. The limited available evidence suggests the current practice of manual oxygen titration commonly does not achieve the prescribed SpO2 target range, resulting in exposure to inadequate and/or excessive concentrations of oxygen, and potential risk of harm. The aim of the research presented in this thesis is to investigate a novel method of oxygen delivery, using nasal high-flow (NHF) with automatic oxygen titration, to achieve SpO 2 within the prescribed target range. An initial feasibility study was undertaken, whereby the closed-loop algorithm used for automatic oxygen titration was tested in participants with resting hypoxaemia. This study also investigated physiological responses to changes in flow and oxygen concentration, enabling the algorithm to be developed and optimised. The percentage of time spent with SpO 2 within a target range using closed-loop control improved during the 12 study visits from 65% at the first visit to 90% at the last visit. The validated version of the algorithm was evaluated in a controlled laboratory-based setting. A randomised crossover study was undertaken involving 42 participants with chronic lung disease who desaturated during exertion. The main aim was to determine the ability of automatic oxygen titration to maintain SpO2 within a target range during a six-minute walk test (6MWT) and subsequent 10-minute recovery period. The comparator interventions were room air and a fixed concentration of oxygen, both delivered using NHF. During the 6MWT, the proportion of time spent with SpO2 in target range using automatic titration was greater than room air; difference 26.0% (95%CI 17.7 to 34.2), P

  • Open Access

    Determination of oxygen saturation compared to a prescribed target range using continuous pulse oximetry in acutely unwell medical patients

    by James C. P. Harper, Ruth Semprini, Nethmi A. Kearns, Lee Hatter, Grace E. Bird, Irene Braithwaite, Allie Eathorne, Mark Weatherall, Richard Beasley

    Background: Both inadequate and excessive administration of oxygen to acutely unwell patients results in risk of harm. Guidelines recommend titration of oxygen to achieve a target oxygen saturation (SpO2) range. Information regarding whether this is being achieved is limited. Methods: In this two-centre non-interventional study we used continuous pulse oximetry in acutely unwell medical patients over a 24-h period to determine the proportion of time spent with SpO2 within the prescribed target range and whether this is influenced by the target range, age, care in a high-dependency area and the number of oxygen adjustments. Results: Eighty participants were included in the analysis. The mean (SD) proportion of time spent in target range was 55.6% (23.6), this was lower in those with a reduced hypercapnic target range (88–92% or below) compared to those with a range of 92–96%; difference − 13.1% (95% CI − 3.0 to − 23.2), P = 0.012. The proportion of time spent above range was 16.2% (22.9); this was higher in those with a reduced hypercapnic range; difference 21.6% (31.4 to 12), P < 0.001. The proportion of time below range was 28.4% (25.2); there was no difference between target ranges. The proportion of time spent in range was higher for those in a high dependency area in the multivariate model; difference 15.5% (95% CI 2.3 to 28.7), P = 0.02. Conclusions: Medical patients receiving oxygen in a ward setting spend significant periods of time with SpO2 both above and below the prescribed target range while receiving oxygen therapy.


  • Open Access

    Automatic versus manual oxygen titration using a novel nasal high-flow device in medical inpatients with an acute illness: a randomised controlled trial

    by James Harper, Nethmi Kearns, Grace Bird, Irene Braithwaite, Allie Eathorne, Nicholas Shortt, Mark Weatherall, Richard Beasley

    Background: Guideline recommendations state oxygen should be administered to acutely unwell patients to achieve a target oxygen saturation (SpO2) range. The current practice of manual oxygen titration frequently results in SpO2 outside of a prescribed range. The aim of this study was to assess the efficacy of automatic oxygen titration using a closed-loop feedback system to achieve SpO2 within a prescribed target range Methods: An open-label randomised parallel group trial was undertaken comparing automatic oxygen titration using a novel nasal high-flow device to manual oxygen titration using nasal high flow. Medical inpatients requiring oxygen therapy in Wellington Regional Hospital, New Zealand with a prescribed target SpO2 range of 88%–92% or 92%–96% were recruited and randomised equally between the interventions for a period of 24 hours. The primary outcome was the proportion of time spent with SpO2 within the prescribed range. Results: 20 patients were included in the analysis. Automatic oxygen titration resulted in a median (IQR) 96.2% (95.2–97.8) of time within the target range compared with 71% (59.4–88.3) with manual titration; difference (95% CI) 24.2% (7.9% to 35%), p2 ≥2% above and ≥2% below range in the automatic titration group, although the point estimate for the differences were small; −1% (−8.2% to −0.04%), p=0.017 and −2.4% (−11.5% to 0.3%), p=0.05 respectively. Conclusions: Nasal high-flow with automatic oxygen titration resulted in a greater proportion of time spent with SpO2 in target range compared with manual titration. Trial registration: The trial was registered with the Australian and New Zealand Clinical Trials Registry (ACTRN12619000901101).


  • Audit of oxygen administration to achieve a target oxygen saturation range in acutely unwell medical patients

    by James Harper, Nethmi Kearns, Grace Bird, Robert McLachlan, Allie Eathorne, Mark Weatherall, Richard Beasley

    Purpose of the study To evaluate documentation of a target oxygen saturation (SpO2) range and ability to achieve this range in acutely unwell inpatients. Study design In this single-centre audit, patients with discharge diagnoses of pneumonia, heart failure and exacerbation of asthma or COPD admitted to Wellington Regional Hospital, New Zealand between 1 June 2019 and 31 August 2019 who received oxygen were identified. In those with a documented target SpO2 range, the proportion of SpO2 measurements in the observation chart which were within, above and below range were determined as well as the maximum and minimum SpO2. Regression analysis was performed to determine whether these outcomes were influenced by the prescribed range, high-dependency care or the number of adjustments to oxygen administration. Results 268 admissions were screened. Of the 100 eligible admissions who received oxygen, a target SpO2 range was documented in 62. The mean (SD) proportion of SpO2 measurements within range was 56.2 (30.6)%. A hypercapnic target SpO2 range was associated with a higher probability of an SpO2 above range; multivariate OR 5.34 (95% CI 1.65 to 17.3, p=0.006) and a lower probability of an SpO2 below range; multivariate OR 0.25 (95% CI 0.08 to 0.80) p=0.02. The mean (SD) maximum SpO2 was similar in those with a target range of 92%–96% versus a hypercapnic range; 96.2 (3.0)% and 95.2 (3.4)%, respectively. Conclusions Oxygen prescription and delivery in this clinical setting was suboptimal. SpO2 values above the designated range are common, particularly in patients with a hypercapnic target range.


  • Open Access

    Closed-Loop Oxygen Control Using a Novel Nasal High-Flow Device: A Randomized Crossover Trial

    by James Cp Harper, Nethmi A Kearns, Ingrid Maijers, Grace E Bird, Irene Braithwaite, Nicholas P Shortt, Allie Eathorne, Mark Weatherall, Richard Beasley

    BACKGROUND: Oxygen administration is recommended for patients with hypoxemia to achieve a target S pO 2 range. Strategies to achieve this in clinical practice are suboptimal. We investigated automatic oxygen titration using a novel nasal high-flow device with closed-loop oxygen control. The objective of this proof-of-concept study was to determine whether closed-loop control was able to respond to desaturation and subsequent recovery in a controlled laboratory-based environment. METHODS: We conducted a single-blind randomized crossover trial in adults with chronic respiratory disease who had a resting S pO 2 ≥ 92% and desaturated to < 90% during a 6-min walk test (6MWT). Nasal high-flow was administered during a 6MWT and a subsequent 10-min rest period with either room air, a fixed concentration of 28% oxygen, or oxygen titrated automatically using closed-loop control. RESULTS: The study involved 42 subjects. Closed-loop control maintained S pO 2 within the target range of 92–96% for a mean (SD) duration of 54.4 ± 30.1% of the 6MWT and 67.3 ± 26.8% of the recovery period. The proportion of time spent with an S pO 2 in the target range during the 6MWT was significantly greater for closed-loop control compared to room air, with a difference of 26.0% (95% CI 17.7–34.2, P < .001); this proportion of time was not significantly different compared to the fixed concentration of 28% oxygen, with a difference of –8.2% (95% CI –16.5 to 0.1, P = .052). The proportion of time spent in the target range during the rest period was significantly greater compared to 28% oxygen, with a difference of 19.3% (95% CI 8.9–29.7, P < .001); this proportion of time was not significantly different compared to room air, with a difference of –9.3% (95% CI –19.7 to 1.0, P = .08). CONCLUSIONS: This study provides proof-of-concept evidence that the novel nasal high-flow device with closed-loop control can respond to changes in S pO 2 outside a target saturation range using a model of exercise-induced desaturation and subsequent recovery.


  • Inhaled Corticosteroids in Acute Asthma: A Systemic Review and Meta-Analysis

    by Nethmi Kearns, Ingrid Maijers, James Harper, Richard Beasley, Mark Weatherall


  • Open Access

    Dose-response relationship of ICS/fast-onset LABA as reliever therapy in asthma

    by Richard Beasley, James Harper, Grace Bird, Harriette Dunphy, Alex Semprini, Ian D. Pavord, Alberto Papi, Mark Weatherall

    Background and objective: The dose-response relationship of inhaled corticosteroid (ICS)/fast-onset long acting beta agonist (LABA) reliever therapy has not been formally addressed. The objective of this retrospective analysis is to ascertain from the available evidence whether ICS/fast-onset LABA administered as reliever therapy has a different dose-response relationship than maintenance fixed dose ICS/fast-onset LABA therapy in reducing risk of severe exacerbations. Methods: A systematic literature review was undertaken to identify randomised controlled trials (RCTs) in which randomised treatments included either i) budesonide/formoterol reliever monotherapy versus budesonide/formoterol fixed dose maintenance with short acting beta agonist (SABA) reliever therapy, or ii) budesonide/formoterol reliever therapy in addition to budesonide/formoterol maintenance versus higher fixed dose maintenance budesonide/formoterol with SABA as reliever therapy. Eligible studies were reviewed to allow determination of the relative potency and efficacy of the comparator regimens to reduce the risk of a severe exacerbation. Results: The one RCT of budesonide/formoterol reliever monotherapy showed a 4.6-fold (95% CI 2.9 to 7.3) greater potency than budesonide/formoterol fixed dose maintenance plus SABA reliever therapy in reducing the risk of severe exacerbations. In the one RCT that compared budesonide/formoterol maintenance and reliever therapy with higher fixed dose maintenance budesonide/formoterol plus SABA reliever therapy, there was an additional 26% (95% CI 4 to 42%) reduction in severe exacerbation risk with the addition of budesonide/formoterol reliever therapy to maintenance budesonide/formoterol, despite a 25% lower total budesonide/formoterol dose. Conclusion: The limited available evidence suggests that budesonide/formoterol reliever therapy has greater potency and efficacy than budesonide/formoterol fixed dose maintenance plus SABA reliever therapy in reducing the risk of a severe exacerbation. This is an important concept which has the potential to guide clinical practice in asthma, although the small number of studies available highlights the need for further research to better define these pharmacological properties.


  • Open Access

    Reply to Boulet and Nair: Inhaled Corticosteroids and Adult Asthma

    by Richard Beasley, James Harper, Grace Bird, Ingrid Maijers, Mark Weatherall, Ian D. Pavord

  • Oral steroid-sparing effect of high-dose inhaled corticosteroids in asthma

    by Ingrid Maijers, Nethmi Kearns, James Harper, Mark Weatherall, Richard Beasley

    Background: The proportion of the efficacy of high-dose inhaled corticosteroids (ICS) in oral corticosteroid-dependent asthma that is due to systemic effects is uncertain. This study aimed to estimate the ICS dose–response relationship for oral corticosteroid-sparing effects in oral corticosteroid-dependent asthma, and to determine the proportion of oral corticosteroid-sparing effects due to their systemic effects, based on the comparative dose–response relationship of ICSversusoral corticosteroids on adrenal suppression.Methods: Systematic review and meta-analysis of randomised controlled trials reporting oral corticosteroid-sparing effects of high-dose ICS in oral corticosteroid-dependent asthma. In addition, reports of oral corticosteroid to ICS dose-equivalence in terms of adrenal suppression were retrieved. The primary outcome was the proportion of the oral corticosteroid-sparing effect of ICS that could be attributed to systemic absorption, per 1000 µg increase of ICS, expressed as a ratio. This ratio estimates the oral corticosteroid sparing effect of ICS due to systemic effects.Results: 11 studies including 1283 participants reporting oral corticosteroid-sparing effects of ICS were identified. The prednisone dose decrease per 1000 µg increase in ICS varied from 2.1 mg to 4.9 mg, depending on the type of ICS. The ratio of the prednisone-sparing effect due to the systemic effects per 1000 µg of fluticasone propionate was 1.02 (95% CI 0.68–2.08) and for budesonide was 0.93 (95% CI 0.63–1.89).Conclusion: In patients with oral corticosteroid-dependent asthma, the limited available evidence suggests that the majority of the oral corticosteroid-sparing effect of high-dose ICS is likely to be due to systemic effects.