Enhanced Transmit Efficiency of a Loop Array Combined With Out‐of‐Phase Passive Dipoles for Thoracic Spinal Cord MRI at 7T
Open Access
- 26 July 2026
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (5) , 2539-2552
Abstract
Purpose: The design of radiofrequency (RF) coils tailored for the target anatomy is necessary to overcome the transmit field homogeneity and penetration issues at Ultra‐High‐Field (UHF). For the spinal cord, the optimal design has not yet been determined. This work intends to demonstrate the added value of a pair of passive dipoles placed under a conventional thoracic spine 4 × 2‐loop array. Methods: The conventional loop array produces a broad transmit field with unnecessary lateral spread. To address this, two passive dipoles were incorporated and tuned out‐of‐phase to actively suppress these lateral side‐lobes and increase field penetration the spinal cord region. The design was numerically optimised using a homogeneous phantom, followed by human voxel model simulations to evaluate performance and specific absorption rate (SAR). Finally, a prototype was tested in a 7T scanner using a homogeneous phantom to acquire experimental maps. Results: Human voxel model simulations demonstrated that the passive dipoles improve the transmit field distribution and predicted a 35% gain in SAR efficiency in the spinal cord region. Correspondingly, phantom experiments showed a 25% gain in transmit efficiency and 15% gain in homogeneity in a selected region of interest compared to the loop‐array‐only reference. Conclusion: Incorporating passive dipoles effectively suppresses unwanted lateral field spread, increasing penetration depth and efficiency in the thoracic spinal cord region. While homogeneous phantom results offer proof of concept, numerical simulations suggest reliable performance in realistic spine anatomy as well as substantial SAR reduction.Keywords
Funding Information
- Agence Nationale de la Recherche (ANR‐23‐CE17‐0019‐01)
This publication has 46 references indexed in Scilit:
- 7T: Physics, safety, and potential clinical applicationsJournal of Magnetic Resonance Imaging, 2017
- Dependence of and field patterns of surface coils on the electrical properties of the sample and the MR operating frequencyConcepts in Magnetic Resonance Part B, 2016
- Ideal current patterns yielding optimal signal‐to‐noise ratio and specific absorption rate in magnetic resonance imaging: Computational methods and physical insightsMagnetic Resonance in Medicine, 2011
- Local specific absorption rate control for parallel transmission by virtual observation pointsMagnetic Resonance in Medicine, 2011
- Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readoutMagnetic Resonance in Medicine, 2010
- Whole‐body imaging at 7T: Preliminary resultsMagnetic Resonance in Medicine, 2008
- Floating shield current suppression trapConcepts in Magnetic Resonance Part B, 2004
- Calculations of B1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically‐accurate human body modelMagnetic Resonance in Medicine, 2001
- The NMR phased arrayMagnetic Resonance in Medicine, 1990
- The intrinsic signal‐to‐noise ratio in NMR imagingMagnetic Resonance in Medicine, 1986