Abstract
This paper presents a case history of veneer slope failures in a non-potable water pond. The paper includes a description of slope construction and post-construction movements, field and laboratory investigations, and stability analyses used to evaluate the cause of the slides. The pond lining system was designed at a 3H : 1V slope and consists from bottom to top of native subgrade, a 0.75 mm thick poly (vinyl chloride) geomembrane, a 270 g/m2 non-woven geotextile, and a 0.3 m thick layer of compacted soil cover over the geotextile. This paper discusses the back-analysis of the slope failures and presents recommendations for back-analyses of other slides involving geosynthetic-lined slopes.Keywords
This publication has 11 references indexed in Scilit:
- Interface shear strength variability and its use in reliability-based landfill stability analysisGeosynthetics International, 2006
- Case history of liner veneer instabilityGeosynthetics International, 2006
- Analysis and design of veneer cover soilsGeosynthetics International, 2005
- Peak versus residual interface strengths for landfill liner and cover designGeosynthetics International, 2004
- Shear Strength Characteristics of PVC Geomembrane-Geosynthetic InterfacesGeosynthetics International, 2001
- Performance of Three-Dimensional Slope Stability Methods in PracticeJournal of Geotechnical and Geoenvironmental Engineering, 1998
- HDPE Geomembrane/Geotextile Interface Shear StrengthJournal of Geotechnical Engineering, 1996
- Landfill Liner Interface Strengths from Torsional‐Ring‐Shear TestsJournal of Geotechnical Engineering, 1994
- The accuracy of equilibrium methods of slope stability analysisEngineering Geology, 1980
- A Method of analysis of the Stability of Embankments Assuming Parallel Inter-Slice ForcesGéotechnique, 1967