Systemic perfusion assessment in patients with univentricular hemodynamics based on blood gas parameters
Open Access
- 28 June 2020
- journal article
- research article
- Published by FSBEI HE I.P. Pavlov SPbSMU MOH Russia in Messenger of ANESTHESIOLOGY AND RESUSCITATION
- Vol. 17 (3) , 6-16
Abstract
The objective: to identify laboratory markers of systemic perfusion in newborns with functional single ventricle on mechanical ventilation after surgical correction. Subjects and methods. Blood gas parameters were retrospectively analyzed in 52 newborns with congenital heart defects with univentricular hemodynamic after surgical correction. All samples were divided into three groups based on arterial blood saturation (SaO2): Group 1 – hypoxia (SaO2 ≤ 65%); Group 2 – normoxemia (SaO2 = 65-85%); Group 3 – hyperoxemia (SaO2 > 85%). Stroke volume and cardiac index were evaluated with echocardiography. The oxygen consumption and carbon metabolism were evaluated by arterial and venous blood gases. Results. The mixed central venous pO2 (PvO2) > 29.5 mm Hg, mixed central venous O2 (SvO2) > 54.5%, arteriovenous difference in saturation (Sa-vO2) < 15.8%, total oxygen content in venous blood (CvO2) > 119 ml/l, oxygen extraction ratio (O2ER) < 19% and the arteriovenous difference in partial pressure of carbon dioxide (dPCO2) < 5.4 mm Hg are cut off criteria for adequate systemic perfusion. PvO2 < 26 mm Hg, SvO2 < 44.5%, Sa-vO 2 > 27%, CvO2 < 88 ml/l, O2ER > 27.7%, dPCO2> 7.9 mm Hg have been associated with decreased systemic perfusion. The logistic regression model including combination of O2ER and dPCO2 predicts adequate systemic flow accuracy of 94.3% (sensitivity 87.5%, specificity 94.7%, p = 0.001). Graphics allow to adapt the mathematical model to clinical practice to verify systemic hypoperfusion in newborns with functional single ventricle. Conclusion: The following cut off parameters allow to assess systemic perfusion in newborns with functional single ventricle: PvO2, SvO2, CvO2, Sa-vO 2, O2ER, and dPCO2. The model for predicting the adequacy of systemic perfusion can be used as an effective tool to monitor hemodynamic status in newborns with functional single ventricle.Keywords
This publication has 25 references indexed in Scilit:
- Theoretical models of changes in haemodynamic parameters and gas exchange in univentricular circulationPatologiya krovoobrashcheniya i kardiokhirurgiya, 2019
- Blood gas analysis in newborns with parallel blood circulation in disturbance of the systemic perfusion after correction of congenital heart diseaseCHILDREN’S HEART AND VASCULAR DISEASES, 2019
- Blood gas analysis in newborns with low cardiac output syndrome after cardiac surgery.The Bulletin of Bakoulev Center "Cardiovascular Diseases", 2018
- ACUTE KIDNEY INJURY IN NEONATES AND INFANTS WITH CONGENITAL HEART DISORDERS AFTER CARDIAC SURGERYNephrology (Saint-Petersburg), 2017
- The Methodology of Doppler-Derived Central Blood Flow Measurements in Newborn InfantsInternational Journal of Pediatrics, 2012
- Hypoplastic Left Heart SyndromeJACC, 2012
- Postoperative management: The role of mixed venous oxygen saturation monitoringSeminars in Thoracic and Cardiovascular Surgery: Pediatric Cardiac Surgery Annual, 2005
- Outcomes after the Norwood operation in neonates with critical aortic stenosis or aortic valve atresiaThe Journal of Thoracic and Cardiovascular Surgery, 2003
- Estimation of Oxygen Delivery in Newborns With a Univentricular CirculationCirculation, 1998
- Balancing the circulation: Theoretic optimization of pulmonary/systemic flow ratio in hypoplastic left heart syndromeJACC, 1994